ZEN30 Dimmer & Dry Contact Relay
This describes the Z-Wave device ZEN30, manufactured by Zooz with the thing type UID of zooz_zen30_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZEN30 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
Features
- Manual or Z-Wave control of 2 separate loads (dimmer + relay)
- Perfect replacement for a fan / light combo (neutral wire required)
- Scene control for multi-tap scenarios on select hubs
- Quick and easy pigtail wire installation (single pole only)
- 4-color LED indicator and air-gap switch for added safety
- Packed with advanced dimming features including ramp rate control, custom on brightness level, and double tap to full brightness
- Remembers and restores on/off status after power failure
- Built-in Z-Wave Plus signal repeater to extend network range
- S2 security protocol and 500 Z-Wave chip
Specifications
- Model Number: ZEN30
- Z-Wave Signal Frequency: 908.42 MHz
- Power: 120 VAC, 60 Hz
- Dimmer Max Load: 75 W LED, 250 W incandescent; DON’T use with tube lights, DC powered fixtures, or chandeliers
- Relay Max Load: 15 A (1/2 HP)
- Operating Temperature: 32-104° F (0-40° C)
- Installation and Use: Indoor only
Scene Control
You can trigger up to 18 scenes or control up to 18 independent Z-Wave devices in your network using the Double Switch. You can assign scenes to 1-tap, 2-tap, 3-tap, 4-tap, 5-tap, or press-and-hold for any of the paddles and the relay button. Your hub needs to support central scene implementation for this feature to be available.
Full list of parameters for ZEN30 Double Switch VER. 3.10 firmware (or 1.20 for VER. 1.0 and 2.20 for VER. 2.0):
https://www.support.getzooz.com/kb/article/468-zen30-double-switch-advanced-settings/
Inclusion Information
- Enable Inclusion for the Z-Wave binding
- Quickly tap the upper paddle on the dimmer 3 times
- The LED indicators will blink to signal communication and remain on for 2 seconds to confirm inclusion
Exclusion Information
- Enable Exclusion for the Z-Wave binding
- Bring your Z-Wave gateway (hub) close to the switch, if possible
- Quickly tap the lower paddle on the dimmer 3 times
General Usage Information
Troubleshooting
- If the switch won’t add to your system, initiate EXCLUSION and tap the lower paddle 3 times quickly
- Tap the upper paddle 4-5 times quickly when adding it
- Bring the gateway controller (hub) closer to the switch, it may be out of range
Factory Reset
If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, press and hold the lower paddle on the dimmer for at least 15 seconds until the LED indicators start flashing, then release. Then immediately press and hold the upper paddle on the dimmer for at least 15 seconds. The LED indicators will flash again to confirm successful reset.
NOTE: All previously recorded activity and custom settings will be erased from the device’s memory.
Channels
The following table summarises the channels available for the ZEN30 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | scene_number | Number | |
Switch 1 | switch_binary1 | switch_binary | Switch | Switch |
Dimmer
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Scene Number
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
This channel provides the scene, and the event as a decimal value in the form <scene>.<event>
. The scene number is set by the device, and the event is as follows -:
Event ID | Event Description |
---|---|
0 | Single key press |
1 | Key released |
2 | Key held down |
3 | Double keypress |
4 | Tripple keypress |
5 | 4 x keypress |
6 | 5 x keypress |
Switch 1
Switch the power on and off.
The switch_binary1
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Device Configuration
The following table provides a summary of the 28 configuration parameters available in the ZEN30. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | LED Indicator Mode for Dimmer | LED Indicator Mode for Dimmer |
2 | LED Indicator Control for Relay | LED Indicator Control for Relay |
3 | LED Indicator Color for Dimmer | Choose the color of the LED indicators for the dimmer |
4 | LED Indicator Color for Relay | LED Indicator Color for Relay |
5 | LED Indicator Brightness for Dimmer | LED Indicator Brightness for Dimmer |
6 | LED Indicator Brightness for Relay | LED Indicator Brightness for Relay |
7 | LED Indicator Mode for Scene Control | LED Indicator Mode for Scene Control |
8 | Auto Turn-Off Timer for Dimmer | Auto Turn-Off Timer for Dimmer |
9 | Auto Turn-On Timer for Dimmer | Auto Turn-On Timer for Dimmer |
10 | Auto Turn-Off Timer for Relay | Auto Turn-Off Timer for Relay |
11 | Auto Turn-On Timer for Relay | Auto Turn-On Timer for Relay |
12 | On Off Status After Power Failure | On Off Status After Power Failure |
13 | Ramp Rate Control for Dimmer | Ramp Rate Control for Dimmer |
14 | Minimum Brightness | Minimum Brightness |
15 | Maximum Brightness | Maximum Brightness |
17 | Double Tap Function for Dimmer | Double Tap Function for Dimmer |
18 | Disable Double Tap | Disable Double Tap |
19 | Smart Bulb Setting | Enable/Disable Load Control for Dimmer |
20 | Remote Control Setting | Enable/Disable Load Control for Relay |
21 | Manual Dimming Speed | Manual Dimming Speed |
22 | Z-Wave Ramp Rate for Dimmer - REMOVED in v1.05 | Z-Wave Ramp Rate for Dimmer |
23 | Default Brightness Level ON for Dimmer | Set custom brightness level (in %) for the dimmer to come on to at single tap. |
24 | Dimmer Reporting Behavior when physical control is disabled. | Set reporting behavior for the dimmer when physical control is disabled. |
25 | Relay Reporting Behavior when physical control is disabled. | Set reporting behavior for the relay when physical control is disabled. |
26 | Night Light Mode | Set the brightness level (default 20%) the dimmer will turn on to when off and when lower paddle is held DOWN for a second. |
28 | Scene Control - Dimmer Paddles | Enable (default) or disable scene control functionality for quick double tap triggers on the dimmer paddles. |
29 | Scene Control - Relay Button | Enable (default) or disable scene control functionality for quick double tap triggers on the relay button. |
30 | Programming on the Dimmer Paddles | Enable or disable programming functionality on the dimmer paddles. If this setting is disabled, then inclusion, exclusion, smart bulb mode no longer work when dimmer paddles are activated (factory reset and scene control will still work) - that means you |
Parameter 1: LED Indicator Mode for Dimmer
LED Indicator Mode for Dimmer Choose if you want the LED indicator to turn on when the switch (light) is on or off, or if you want it to remain on or off at all times. This setting is for the top status indicator only.
6 x TAP UPPER PADDLE to change the LED mode. The following option values may be configured -:
Value | Description |
---|---|
0 | ON when switch is OFF and OFF when switch is ON |
1 | ON when switch is ON and OFF when switch is OFF |
2 | LED indicator is always OFF |
3 | LED indicator is always ON |
The manufacturer defined default value is 0
(ON when switch is OFF and OFF when switch is ON).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: LED Indicator Control for Relay
LED Indicator Control for Relay Choose if you want the LED indicator to turn on when the relay is on or off, or if you want it to remain on or off at all times.
6 x TAP RELAY BUTTONto change the LED mode. The following option values may be configured -:
Value | Description |
---|---|
0 | ON when relay is OFF and OFF when relay is ON |
1 | ON when relay is ON and OFF when relay is OFF |
2 | LED indicator is always OFF |
3 | LED indicator is always ON |
The manufacturer defined default value is 0
(ON when relay is OFF and OFF when relay is ON).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: LED Indicator Color for Dimmer
Choose the color of the LED indicators for the dimmer
The following option values may be configured -:
Value | Description |
---|---|
0 | White (default) |
1 | Blue |
2 | Green |
3 | Red |
The manufacturer defined default value is 0
(White (default)).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: LED Indicator Color for Relay
LED Indicator Color for Relay Choose the color of the LED indicator for the relay The following option values may be configured -:
Value | Description |
---|---|
0 | White (default) |
1 | Blue |
2 | Green |
3 | Red |
The manufacturer defined default value is 0
(White (default)).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 5: LED Indicator Brightness for Dimmer
LED Indicator Brightness for Dimmer Choose the LED indicators’ brightness level for the dimmer The following option values may be configured -:
Value | Description |
---|---|
0 | Bright (100%) |
1 | Medium (60%) |
2 | Low (30% - default) |
The manufacturer defined default value is 2
(Low (30% - default)).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter 6: LED Indicator Brightness for Relay
LED Indicator Brightness for Relay Choose the LED indicators’ brightness level for the relay The following option values may be configured -:
Value | Description |
---|---|
0 | Bright (100%) |
1 | Medium (60%) |
2 | Low (30% - default) |
The manufacturer defined default value is 2
(Low (30% - default)).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Parameter 7: LED Indicator Mode for Scene Control
LED Indicator Mode for Scene Control Choose if you want the LED indicators next to the dimmer to light up when a scene is selected. You’ll see 1 to 5 LEDs light up for 1 – 5 tap triggers and 6 LEDs light up for the press-and-hold trigger of any paddle / button used. The following option values may be configured -:
Value | Description |
---|---|
0 | Enabled to indicate scene triggers |
1 | Disabled to indicate scene triggers (default) |
The manufacturer defined default value is 1
(Disabled to indicate scene triggers (default)).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Parameter 8: Auto Turn-Off Timer for Dimmer
Auto Turn-Off Timer for Dimmer Use this parameter to set the time after which you want the dimmer to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_8_4
and is of type INTEGER
.
Parameter 9: Auto Turn-On Timer for Dimmer
Auto Turn-On Timer for Dimmer Use this parameter to set the time after which you want the dimmer to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_9_4
and is of type INTEGER
.
Parameter 10: Auto Turn-Off Timer for Relay
Auto Turn-Off Timer for Relay Use this parameter to set the time after which you want the relay to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_10_4
and is of type INTEGER
.
Parameter 11: Auto Turn-On Timer for Relay
Auto Turn-On Timer for Relay Use this parameter to set the time after which you want the relay to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_11_4
and is of type INTEGER
.
Parameter 12: On Off Status After Power Failure
On Off Status After Power Failure Set the on/off status of the device after power failure. The following option values may be configured -:
Value | Description |
---|---|
0 | Dimmer and relay forced to OFF |
1 | Dimmer forced to OFF, relay forced to ON |
2 | Dimmer forced to ON, relay forced to OFF |
3 | Restores status for dimmer and relay (default) |
4 | Restores status for dimmer, relay forced to ON |
5 | Restores status for dimmer, relay forced to OFF |
6 | Dimmer forced to ON, restores status for relay |
7 | Dimmer forced to OFF, restores status for relay |
8 | Dimmer and relay forced to ON |
The manufacturer defined default value is 3
(Restores status for dimmer and relay (default)).
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Parameter 13: Ramp Rate Control for Dimmer
Ramp Rate Control for Dimmer Adjust the ramp rate for the dimmer (fade-in / fade-out effect for ON/OFF operation). Values correspond to the number of seconds it takes for the dimmer to reach full brightness or turn OFF when operated manually. Values in the range 0 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Parameter 14: Minimum Brightness
Minimum Brightness Set the minimum brightness level (in %) for the dimmer. You won’t be able to dim the light below the set value. Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
Parameter 15: Maximum Brightness
Maximum Brightness Set the maximum brightness level (in %) for the dimmer. You won’t be able to add brightness to the light beyond the set value. Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
Parameter 17: Double Tap Function for Dimmer
Double Tap Function for Dimmer Choose if you want the dimmer to turn ON to full brightness or custom brightness level after you double-tap the upper paddle. The following option values may be configured -:
Value | Description |
---|---|
0 | ON to full brightness with double tap (default) |
1 | ON to brightness set in #15 with double tap |
The manufacturer defined default value is 0
(ON to full brightness with double tap (default)).
This parameter has the configuration ID config_17_1
and is of type INTEGER
.
Parameter 18: Disable Double Tap
Disable Double Tap Enable or disable the double-tap function and assign brightness level to single tap The following option values may be configured -:
Value | Description |
---|---|
0 | Full/max brightness level enabled (default) |
1 | Disabled, single tap for last brightness |
2 | Disabled, single tap to full brightness |
The manufacturer defined default value is 0
(Full/max brightness level enabled (default)).
This parameter has the configuration ID config_18_1
and is of type INTEGER
.
Parameter 19: Smart Bulb Setting
Enable/Disable Load Control for Dimmer Enable or disable direct manual and Z-Wave control of the connected light. Works great for smart bulb control. If disabled, the dimmer will no longer control the connected bulb directly but will still send on/off and brightness reports to the hub so you can use them to create automations for your smart bulbs or other switches. Scenes and other functionality will still be available through paddles.
4 TAP’N’HOLD LOWER PADDLE to change the mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Manual control disabled |
1 | Manual control enabled (default) |
2 | Manual and Z-Wave control disabled |
The manufacturer defined default value is 1
(Manual control enabled (default)).
This parameter has the configuration ID config_19_1
and is of type INTEGER
.
Parameter 20: Remote Control Setting
Enable/Disable Load Control for Relay Enable or disable direct manual and Z-Wave control of the connected load. Works great for smart bulbs or any type of remote / scene control. If disabled, the relay will no longer control the connected load directly but will still send on/off reports to the hub so you can use them to create automations for your smart bulbs or other devices. Scenes and other functionality will still be available through the button.
4 TAP’N’HOLD THE BUTTON to change the mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Manual control disabled |
1 | Manual control enabled (default) |
2 | Manual and Z-Wave control disabled |
The manufacturer defined default value is 1
(Manual control enabled (default)).
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
Parameter 21: Manual Dimming Speed
Manual Dimming Speed Choose how many seconds it takes for the dimmer to go from 0% to 100% brightness when pressing and holding the paddle. Increase the value to decrease the dimming speed. Values in the range 1 to 99 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_21_1
and is of type INTEGER
.
Parameter 22: Z-Wave Ramp Rate for Dimmer - REMOVED in v1.05
Z-Wave Ramp Rate for Dimmer Parameter REMOVED as of firmware version 1.05 Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_22_1
and is of type INTEGER
.
Parameter 23: Default Brightness Level ON for Dimmer
Set custom brightness level (in %) for the dimmer to come on to at single tap. Set custom brightness level (in %) for the dimmer to come on to at single tap Values in the range 0 to 99 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_23_1
and is of type INTEGER
.
Parameter 24: Dimmer Reporting Behavior when physical control is disabled.
Set reporting behavior for the dimmer when physical control is disabled. 0 – dimmer reports on/off status and brightness level and changes LED indicator state even if physical and Z-Wave control is disabled (default).
1 – dimmer doesn't report on/off/brightness status changes and it doesn't change the LED indicator state when physical (and Z-Wave) control is disabled and paddles are pressed or the dimmer receives on/off commands from the hub. The following option values may be configured -:
Value | Description |
---|---|
0 | disabled (default) |
1 | Enabled |
The manufacturer defined default value is 0
(disabled (default)).
This parameter has the configuration ID config_24_1
and is of type INTEGER
.
Parameter 25: Relay Reporting Behavior when physical control is disabled.
Set reporting behavior for the relay when physical control is disabled. 0 – relay reports on/off status and changes LED indicator state even if physical and Z-Wave control is disabled (default).
1 – relay doesn't report on/off status changes and it doesn't change the LED indicator state when physical (and Z-Wave) control is disabled and the button is pressed or the relay receives on/off commands from the hub. The following option values may be configured -:
Value | Description |
---|---|
0 | disabled (default) |
1 | Enabled |
The manufacturer defined default value is 0
(disabled (default)).
This parameter has the configuration ID config_25_1
and is of type INTEGER
.
Parameter 26: Night Light Mode
Set the brightness level (default 20%) the dimmer will turn on to when off and when lower paddle is held DOWN for a second. Set the brightness level (default 20%) the dimmer will turn on to when off and when lower paddle is held DOWN for a second. Values in the range 0 to 99 may be set.
The manufacturer defined default value is 20
.
This parameter has the configuration ID config_26_1
and is of type INTEGER
.
Parameter 28: Scene Control - Dimmer Paddles
Enable (default) or disable scene control functionality for quick double tap triggers on the dimmer paddles. Enable (default) or disable scene control functionality for quick double tap triggers on the dimmer paddles. The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | enabled (default) |
The manufacturer defined default value is 1
(enabled (default)).
This parameter has the configuration ID config_28_1
and is of type INTEGER
.
Parameter 29: Scene Control - Relay Button
Enable (default) or disable scene control functionality for quick double tap triggers on the relay button. Enable (default) or disable scene control functionality for quick double tap triggers on the relay button. The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | enabled (default) |
The manufacturer defined default value is 0
(disabled).
This parameter has the configuration ID config_29_1
and is of type INTEGER
.
Parameter 30: Programming on the Dimmer Paddles
Enable or disable programming functionality on the dimmer paddles. If this setting is disabled, then inclusion, exclusion, smart bulb mode no longer work when dimmer paddles are activated (factory reset and scene control will still work) - that means you Enable or disable programming functionality on the dimmer paddles. If this setting is disabled, then inclusion, exclusion, smart bulb mode no longer work when dimmer paddles are activated (factory reset and scene control will still work) - that means you can now use triple-tap triggers on the dimmer for scenes and remote control of other devices. The following option values may be configured -:
Value | Description |
---|---|
0 | enabled (default) |
1 | Disabled |
The manufacturer defined default value is 0
(enabled (default)).
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZEN30 supports 3 association groups.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 1 node.
Group 2: BASIC_SET (dimmer)
The dimmer supports Group 2 with up to 5 devices and will send BASIC_SET report to other devices in Group 2 to communicate status changes.
Association group 2 supports 5 nodes.
Group 3: BASIC_SET (relay)
The relay supports Group 3 with up to 5 devices BASIC_SET report to other devices in Group 3 if its status changes.
Association group 3 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_CENTRAL_SCENE_V3 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | |
COMMAND_CLASS_SECURITY_V2 |
Endpoint 1
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.