--- layout: documentation title: ZEN30 - ZWave --- {% include base.html %} # ZEN30 Dimmer & Dry Contact Relay This describes the Z-Wave device *ZEN30*, manufactured by *[Zooz](http://www.getzooz.com/)* with the thing type UID of ```zooz_zen30_00_000```. The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![ZEN30 product image](https://opensmarthouse.org/zwavedatabase/1182/image/) The ZEN30 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview Features * Manual or Z-Wave control of 2 separate loads (dimmer + relay) * Perfect replacement for a fan / light combo (neutral wire required) * Scene control for multi-tap scenarios on select hubs * Quick and easy pigtail wire installation (single pole only) * 4-color LED indicator and air-gap switch for added safety * Packed with advanced dimming features including ramp rate control, custom on brightness level, and double tap to full brightness * Remembers and restores on/off status after power failure * Built-in Z-Wave Plus signal repeater to extend network range * S2 security protocol and 500 Z-Wave chip Specifications * Model Number: ZEN30 * Z-Wave Signal Frequency: 908.42 MHz * Power: 120 VAC, 60 Hz * Dimmer Max Load: 75 W LED, 250 W incandescent; DON’T use with tube lights, DC powered fixtures, or chandeliers * Relay Max Load: 15 A (1/2 HP) * Operating Temperature: 32-104° F (0-40° C) * Installation and Use: Indoor only Scene Control You can trigger up to 18 scenes or control up to 18 independent Z-Wave devices in your network using the Double Switch. You can assign scenes to 1-tap, 2-tap, 3-tap, 4-tap, 5-tap, or press-and-hold for any of the paddles and the relay button. Your hub needs to support central scene implementation for this feature to be available. Full list of parameters for ZEN30 Double Switch VER. 3.10 firmware (or 1.20 for VER. 1.0 and 2.20 for VER. 2.0): https://www.support.getzooz.com/kb/article/468-zen30-double-switch-advanced-settings/ ### Inclusion Information 1. Enable Inclusion for the Z-Wave binding 2. Quickly tap the upper paddle on the dimmer 3 times 3. The LED indicators will blink to signal communication and remain on for 2 seconds to confirm inclusion ### Exclusion Information 1. Enable Exclusion for the Z-Wave binding 2. Bring your Z-Wave gateway (hub) close to the switch, if possible 3. Quickly tap the lower paddle on the dimmer 3 times ### General Usage Information Troubleshooting 1. If the switch won’t add to your system, initiate EXCLUSION and tap the lower paddle 3 times quickly 2. Tap the upper paddle 4-5 times quickly when adding it 3. Bring the gateway controller (hub) closer to the switch, it may be out of range Factory Reset If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To complete the reset process manually, press and hold the lower paddle on the dimmer for at least 15 seconds until the LED indicators start flashing, then release. Then immediately press and hold the upper paddle on the dimmer for at least 15 seconds. The LED indicators will flash again to confirm successful reset. NOTE: All previously recorded activity and custom settings will be erased from the device’s memory. ## Channels The following table summarises the channels available for the ZEN30 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer | | Scene Number | scene_number | scene_number | | Number | | Switch 1 | switch_binary1 | switch_binary | Switch | Switch | ### Dimmer The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off. The ```switch_dimmer``` channel is of type ```switch_dimmer``` and supports the ```Dimmer``` item and is in the ```DimmableLight``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item. This channel provides the scene, and the event as a decimal value in the form ```.```. The scene number is set by the device, and the event is as follows -: | Event ID | Event Description | |----------|--------------------| | 0 | Single key press | | 1 | Key released | | 2 | Key held down | | 3 | Double keypress | | 4 | Tripple keypress | | 5 | 4 x keypress | | 6 | 5 x keypress | ### Switch 1 Switch the power on and off. The ```switch_binary1``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ## Device Configuration The following table provides a summary of the 28 configuration parameters available in the ZEN30. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | LED Indicator Mode for Dimmer | LED Indicator Mode for Dimmer | | 2 | LED Indicator Control for Relay | LED Indicator Control for Relay | | 3 | LED Indicator Color for Dimmer | Choose the color of the LED indicators for the dimmer | | 4 | LED Indicator Color for Relay | LED Indicator Color for Relay | | 5 | LED Indicator Brightness for Dimmer | LED Indicator Brightness for Dimmer | | 6 | LED Indicator Brightness for Relay | LED Indicator Brightness for Relay | | 7 | LED Indicator Mode for Scene Control | LED Indicator Mode for Scene Control | | 8 | Auto Turn-Off Timer for Dimmer | Auto Turn-Off Timer for Dimmer | | 9 | Auto Turn-On Timer for Dimmer | Auto Turn-On Timer for Dimmer | | 10 | Auto Turn-Off Timer for Relay | Auto Turn-Off Timer for Relay | | 11 | Auto Turn-On Timer for Relay | Auto Turn-On Timer for Relay | | 12 | On Off Status After Power Failure | On Off Status After Power Failure | | 13 | Ramp Rate Control for Dimmer | Ramp Rate Control for Dimmer | | 14 | Minimum Brightness | Minimum Brightness | | 15 | Maximum Brightness | Maximum Brightness | | 17 | Double Tap Function for Dimmer | Double Tap Function for Dimmer | | 18 | Disable Double Tap | Disable Double Tap | | 19 | Smart Bulb Setting | Enable/Disable Load Control for Dimmer | | 20 | Remote Control Setting | Enable/Disable Load Control for Relay | | 21 | Manual Dimming Speed | Manual Dimming Speed | | 22 | Z-Wave Ramp Rate for Dimmer - REMOVED in v1.05 | Z-Wave Ramp Rate for Dimmer | | 23 | Default Brightness Level ON for Dimmer | Set custom brightness level (in %) for the dimmer to come on to at single tap. | | 24 | Dimmer Reporting Behavior when physical control is disabled. | Set reporting behavior for the dimmer when physical control is disabled. | | 25 | Relay Reporting Behavior when physical control is disabled. | Set reporting behavior for the relay when physical control is disabled. | | 26 | Night Light Mode | Set the brightness level (default 20%) the dimmer will turn on to when off and when lower paddle is held DOWN for a second. | | 28 | Scene Control - Dimmer Paddles | Enable (default) or disable scene control functionality for quick double tap triggers on the dimmer paddles. | | 29 | Scene Control - Relay Button | Enable (default) or disable scene control functionality for quick double tap triggers on the relay button. | | 30 | Programming on the Dimmer Paddles | Enable or disable programming functionality on the dimmer paddles. If this setting is disabled, then inclusion, exclusion, smart bulb mode no longer work when dimmer paddles are activated (factory reset and scene control will still work) - that means you | ### Parameter 1: LED Indicator Mode for Dimmer LED Indicator Mode for Dimmer Choose if you want the LED indicator to turn on when the switch (light) is on or off, or if you want it to remain on or off at all times. This setting is for the top status indicator only. 6 x TAP UPPER PADDLE to change the LED mode. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | ON when switch is OFF and OFF when switch is ON | | 1 | ON when switch is ON and OFF when switch is OFF | | 2 | LED indicator is always OFF | | 3 | LED indicator is always ON | The manufacturer defined default value is ```0``` (ON when switch is OFF and OFF when switch is ON). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: LED Indicator Control for Relay LED Indicator Control for Relay Choose if you want the LED indicator to turn on when the relay is on or off, or if you want it to remain on or off at all times. 6 x TAP RELAY BUTTONto change the LED mode. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | ON when relay is OFF and OFF when relay is ON | | 1 | ON when relay is ON and OFF when relay is OFF | | 2 | LED indicator is always OFF | | 3 | LED indicator is always ON | The manufacturer defined default value is ```0``` (ON when relay is OFF and OFF when relay is ON). This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: LED Indicator Color for Dimmer Choose the color of the LED indicators for the dimmer The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | White (default) | | 1 | Blue | | 2 | Green | | 3 | Red | The manufacturer defined default value is ```0``` (White (default)). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: LED Indicator Color for Relay LED Indicator Color for Relay Choose the color of the LED indicator for the relay The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | White (default) | | 1 | Blue | | 2 | Green | | 3 | Red | The manufacturer defined default value is ```0``` (White (default)). This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 5: LED Indicator Brightness for Dimmer LED Indicator Brightness for Dimmer Choose the LED indicators’ brightness level for the dimmer The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Bright (100%) | | 1 | Medium (60%) | | 2 | Low (30% - default) | The manufacturer defined default value is ```2``` (Low (30% - default)). This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 6: LED Indicator Brightness for Relay LED Indicator Brightness for Relay Choose the LED indicators’ brightness level for the relay The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Bright (100%) | | 1 | Medium (60%) | | 2 | Low (30% - default) | The manufacturer defined default value is ```2``` (Low (30% - default)). This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```. ### Parameter 7: LED Indicator Mode for Scene Control LED Indicator Mode for Scene Control Choose if you want the LED indicators next to the dimmer to light up when a scene is selected. You’ll see 1 to 5 LEDs light up for 1 – 5 tap triggers and 6 LEDs light up for the press-and-hold trigger of any paddle / button used. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Enabled to indicate scene triggers | | 1 | Disabled to indicate scene triggers (default) | The manufacturer defined default value is ```1``` (Disabled to indicate scene triggers (default)). This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 8: Auto Turn-Off Timer for Dimmer Auto Turn-Off Timer for Dimmer Use this parameter to set the time after which you want the dimmer to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_8_4``` and is of type ```INTEGER```. ### Parameter 9: Auto Turn-On Timer for Dimmer Auto Turn-On Timer for Dimmer Use this parameter to set the time after which you want the dimmer to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_9_4``` and is of type ```INTEGER```. ### Parameter 10: Auto Turn-Off Timer for Relay Auto Turn-Off Timer for Relay Use this parameter to set the time after which you want the relay to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_10_4``` and is of type ```INTEGER```. ### Parameter 11: Auto Turn-On Timer for Relay Auto Turn-On Timer for Relay Use this parameter to set the time after which you want the relay to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes. Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_11_4``` and is of type ```INTEGER```. ### Parameter 12: On Off Status After Power Failure On Off Status After Power Failure Set the on/off status of the device after power failure. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Dimmer and relay forced to OFF | | 1 | Dimmer forced to OFF, relay forced to ON | | 2 | Dimmer forced to ON, relay forced to OFF | | 3 | Restores status for dimmer and relay (default) | | 4 | Restores status for dimmer, relay forced to ON | | 5 | Restores status for dimmer, relay forced to OFF | | 6 | Dimmer forced to ON, restores status for relay | | 7 | Dimmer forced to OFF, restores status for relay | | 8 | Dimmer and relay forced to ON | The manufacturer defined default value is ```3``` (Restores status for dimmer and relay (default)). This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```. ### Parameter 13: Ramp Rate Control for Dimmer Ramp Rate Control for Dimmer Adjust the ramp rate for the dimmer (fade-in / fade-out effect for ON/OFF operation). Values correspond to the number of seconds it takes for the dimmer to reach full brightness or turn OFF when operated manually. Values in the range 0 to 99 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_13_1``` and is of type ```INTEGER```. ### Parameter 14: Minimum Brightness Minimum Brightness Set the minimum brightness level (in %) for the dimmer. You won’t be able to dim the light below the set value. Values in the range 1 to 99 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_14_1``` and is of type ```INTEGER```. ### Parameter 15: Maximum Brightness Maximum Brightness Set the maximum brightness level (in %) for the dimmer. You won’t be able to add brightness to the light beyond the set value. Values in the range 1 to 99 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_15_1``` and is of type ```INTEGER```. ### Parameter 17: Double Tap Function for Dimmer Double Tap Function for Dimmer Choose if you want the dimmer to turn ON to full brightness or custom brightness level after you double-tap the upper paddle. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | ON to full brightness with double tap (default) | | 1 | ON to brightness set in #15 with double tap | The manufacturer defined default value is ```0``` (ON to full brightness with double tap (default)). This parameter has the configuration ID ```config_17_1``` and is of type ```INTEGER```. ### Parameter 18: Disable Double Tap Disable Double Tap Enable or disable the double-tap function and assign brightness level to single tap The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Full/max brightness level enabled (default) | | 1 | Disabled, single tap for last brightness | | 2 | Disabled, single tap to full brightness | The manufacturer defined default value is ```0``` (Full/max brightness level enabled (default)). This parameter has the configuration ID ```config_18_1``` and is of type ```INTEGER```. ### Parameter 19: Smart Bulb Setting Enable/Disable Load Control for Dimmer Enable or disable direct manual and Z-Wave control of the connected light. Works great for smart bulb control. If disabled, the dimmer will no longer control the connected bulb directly but will still send on/off and brightness reports to the hub so you can use them to create automations for your smart bulbs or other switches. Scenes and other functionality will still be available through paddles. 4 TAP’N’HOLD LOWER PADDLE to change the mode. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Manual control disabled | | 1 | Manual control enabled (default) | | 2 | Manual and Z-Wave control disabled | The manufacturer defined default value is ```1``` (Manual control enabled (default)). This parameter has the configuration ID ```config_19_1``` and is of type ```INTEGER```. ### Parameter 20: Remote Control Setting Enable/Disable Load Control for Relay Enable or disable direct manual and Z-Wave control of the connected load. Works great for smart bulbs or any type of remote / scene control. If disabled, the relay will no longer control the connected load directly but will still send on/off reports to the hub so you can use them to create automations for your smart bulbs or other devices. Scenes and other functionality will still be available through the button. 4 TAP’N’HOLD THE BUTTON to change the mode. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Manual control disabled | | 1 | Manual control enabled (default) | | 2 | Manual and Z-Wave control disabled | The manufacturer defined default value is ```1``` (Manual control enabled (default)). This parameter has the configuration ID ```config_20_1``` and is of type ```INTEGER```. ### Parameter 21: Manual Dimming Speed Manual Dimming Speed Choose how many seconds it takes for the dimmer to go from 0% to 100% brightness when pressing and holding the paddle. Increase the value to decrease the dimming speed. Values in the range 1 to 99 may be set. The manufacturer defined default value is ```4```. This parameter has the configuration ID ```config_21_1``` and is of type ```INTEGER```. ### Parameter 22: Z-Wave Ramp Rate for Dimmer - REMOVED in v1.05 Z-Wave Ramp Rate for Dimmer Parameter REMOVED as of firmware version 1.05 Values in the range 0 to 1 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_22_1``` and is of type ```INTEGER```. ### Parameter 23: Default Brightness Level ON for Dimmer Set custom brightness level (in %) for the dimmer to come on to at single tap. Set custom brightness level (in %) for the dimmer to come on to at single tap Values in the range 0 to 99 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_23_1``` and is of type ```INTEGER```. ### Parameter 24: Dimmer Reporting Behavior when physical control is disabled. Set reporting behavior for the dimmer when physical control is disabled. 0 – dimmer reports on/off status and brightness level and changes LED indicator state even if physical and Z-Wave control is disabled (default).  1 – dimmer doesn't report on/off/brightness status changes and it doesn't change the LED indicator state when physical (and Z-Wave) control is disabled and paddles are pressed or the dimmer receives on/off commands from the hub. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | disabled (default) | | 1 | Enabled | The manufacturer defined default value is ```0``` (disabled (default)). This parameter has the configuration ID ```config_24_1``` and is of type ```INTEGER```. ### Parameter 25: Relay Reporting Behavior when physical control is disabled. Set reporting behavior for the relay when physical control is disabled. 0 – relay reports on/off status and changes LED indicator state even if physical and Z-Wave control is disabled (default).  1 – relay doesn't report on/off status changes and it doesn't change the LED indicator state when physical (and Z-Wave) control is disabled and the button is pressed or the relay receives on/off commands from the hub. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | disabled (default) | | 1 | Enabled | The manufacturer defined default value is ```0``` (disabled (default)). This parameter has the configuration ID ```config_25_1``` and is of type ```INTEGER```. ### Parameter 26: Night Light Mode Set the brightness level (default 20%) the dimmer will turn on to when off and when lower paddle is held DOWN for a second. Set the brightness level (default 20%) the dimmer will turn on to when off and when lower paddle is held DOWN for a second. Values in the range 0 to 99 may be set. The manufacturer defined default value is ```20```. This parameter has the configuration ID ```config_26_1``` and is of type ```INTEGER```. ### Parameter 28: Scene Control - Dimmer Paddles Enable (default) or disable scene control functionality for quick double tap triggers on the dimmer paddles. Enable (default) or disable scene control functionality for quick double tap triggers on the dimmer paddles. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | enabled (default) | The manufacturer defined default value is ```1``` (enabled (default)). This parameter has the configuration ID ```config_28_1``` and is of type ```INTEGER```. ### Parameter 29: Scene Control - Relay Button Enable (default) or disable scene control functionality for quick double tap triggers on the relay button. Enable (default) or disable scene control functionality for quick double tap triggers on the relay button. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | | 1 | enabled (default) | The manufacturer defined default value is ```0``` (disabled). This parameter has the configuration ID ```config_29_1``` and is of type ```INTEGER```. ### Parameter 30: Programming on the Dimmer Paddles Enable or disable programming functionality on the dimmer paddles. If this setting is disabled, then inclusion, exclusion, smart bulb mode no longer work when dimmer paddles are activated (factory reset and scene control will still work) - that means you Enable or disable programming functionality on the dimmer paddles. If this setting is disabled, then inclusion, exclusion, smart bulb mode no longer work when dimmer paddles are activated (factory reset and scene control will still work) - that means you can now use triple-tap triggers on the dimmer for scenes and remote control of other devices. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | enabled (default) | | 1 | Disabled | The manufacturer defined default value is ```0``` (enabled (default)). This parameter has the configuration ID ```config_30_1``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The ZEN30 supports 3 association groups. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 supports 1 node. ### Group 2: BASIC_SET (dimmer) The dimmer supports Group 2 with up to 5 devices and will send BASIC_SET report to other devices in Group 2 to communicate status changes. Association group 2 supports 5 nodes. ### Group 3: BASIC_SET (relay) The relay supports Group 3 with up to 5 devices BASIC_SET report to other devices in Group 3 if its status changes. Association group 3 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SWITCH_MULTILEVEL_V3| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_CENTRAL_SCENE_V3| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | | COMMAND_CLASS_SECURITY_V2| | #### Endpoint 1 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | ### Documentation Links * [Manual](https://opensmarthouse.org/zwavedatabase/1182/reference/zooz-s2-double-switch-zen30-ver1-manual-online.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1182).