11 KiB
layout | title |
---|---|
documentation | YRD240-ZW2 - ZWave |
{% include base.html %}
YRD240-ZW2 Yale Assure Lock 2
This describes the Z-Wave device YRD240-ZW2, manufactured by ASSA ABLOY with the thing type UID of yale_yrd240_00_000
.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The YRD240-ZW2 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
Overview
Never worry about carrying around or losing your keys again. The Assure Lock 2 features Z-Wave and seamlessly integrates into 50+ home automation and security systems including SmartThings, Alarm.com, Honeywell, ADT, Wink and more! When added to most Z-Wave™ automation systems, lock and unlock your door, create pin codes, view access history and receive notifications from anywhere.
Inclusion Information
To include the lock in a Z-Wave Network (taken from the installation manual):
- On your lock keypad, enter your programming code, followed by the gear icon
- Press the 7 key, followed by the gear icon
- Press the 1 key, followed by the gear icon
Exclusion Information
To exclude the lock from a Z-Wave Network (taken from the installation manual):
- On your lock keypad, enter your programming code, followed by the gear icon
- Press the 7 key, followed by the gear icon
- Press the 3 key, followed by the gear icon
General Usage Information
Please note that for my lock, YMMV, it is not possible to set the re-lock configurations, these must be set via the Yale app or some other means. The re-lock timing cannot be changed at all, and the re-lock can be changed to off, but not to on.
Channels
The following table summarises the channels available for the YRD240-ZW2 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Door Lock | lock_door | lock_door | Door | Switch |
Alarm (entry) | alarm_entry | alarm_entry | Door | Switch |
Alarm (battery) | alarm_battery | alarm_battery | LowBattery | Switch |
Alarm (raw) | alarm_raw | alarm_raw | String | |
Battery Level | battery-level | system.battery_level | Battery | Number |
Clock Time Offset | time_offset | time_offset | Time | Number |
Door Lock
Lock and unlock the door.
The lock_door
channel is of type lock_door
and supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
Alarm (entry)
Indicates if the entry alarm is triggered.
The alarm_entry
channel is of type alarm_entry
and supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Open |
OFF | Closed |
Alarm (battery)
Indicates if the low battery alarm is triggered.
The alarm_battery
channel is of type alarm_battery
and supports the Switch
item and is in the LowBattery
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Alarm (raw)
Provides alarm parameters as json string.
The alarm_raw
channel is of type alarm_raw
and supports the String
item. This is a read only channel so will only be updated following state changes from the device.
This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules.
Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
Clock Time Offset
Provides the current time difference for the devices time.
The time_offset
channel is of type time_offset
and supports the Number
item and is in the Time
category.
Device Configuration
The following table provides a summary of the 11 configuration parameters available in the YRD240-ZW2. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Volume Level | |
2 | Auto Relock | |
3 | Auto Relock Time | Auto Relock after 10 to 180 seconds |
4 | Wrong Code Entry Limit | 3 to 10 attempts allowed |
5 | Language | |
7 | Shut Down Time (after wrong code entries) | 10 to 180 seconds before more attempts |
8 | Operating Mode | |
11 | One Touch Locking | |
12 | Privacy Mode | Disables using a passcode to unlock |
13 | Lock Status LED | |
15 | Reset to Factory Defaults | Lock will execute Reset To Factory! |
Lock Timeout | Sets the time after which the door will auto lock |
Parameter 1: Volume Level
The following option values may be configured, in addition to values in the range 1 to 3 -:
Value | Description |
---|---|
1 | High |
2 | Low |
3 | Silent |
The manufacturer defined default value is 2
(Low).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Auto Relock
The following option values may be configured, in addition to values in the range 0 to 0 -:
Value | Description |
---|---|
-1 | Off |
0 | On |
The manufacturer defined default value is -1
(Off).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: Auto Relock Time
Auto Relock after 10 to 180 seconds
Values in the range 10 to 180 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: Wrong Code Entry Limit
3 to 10 attempts allowed
Values in the range 3 to 10 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 5: Language
The following option values may be configured, in addition to values in the range 1 to 3 -:
Value | Description |
---|---|
1 | English |
2 | Spanish |
3 | French |
The manufacturer defined default value is 1
(English).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter 7: Shut Down Time (after wrong code entries)
10 to 180 seconds before more attempts
Values in the range 10 to 180 may be set.
The manufacturer defined default value is 60
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Parameter 8: Operating Mode
The following option values may be configured, in addition to values in the range 0 to 3 -:
Value | Description |
---|---|
0 | Normal Mode |
1 | Vacation Mode, key only |
2 | Privacy Mode, no keypad |
3 | Passage Mode, no auto lock |
The manufacturer defined default value is 0
(Normal Mode).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Parameter 11: One Touch Locking
The following option values may be configured, in addition to values in the range 0 to 0 -:
Value | Description |
---|---|
-1 | On |
0 | Off |
The manufacturer defined default value is -1
(On).
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Parameter 12: Privacy Mode
Disables using a passcode to unlock
The following option values may be configured, in addition to values in the range 0 to 0 -:
Value | Description |
---|---|
-1 | On |
0 | Off |
The manufacturer defined default value is 0
(Off).
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Parameter 13: Lock Status LED
The following option values may be configured, in addition to values in the range 0 to 0 -:
Value | Description |
---|---|
-1 | On |
0 | Off |
The manufacturer defined default value is 0
(Off).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Parameter 15: Reset to Factory Defaults
Lock will execute Reset To Factory! This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 0 to 0 -:
Value | Description |
---|---|
-1 | Reset to Factory On |
0 | Reset to Factory Off |
The manufacturer defined default value is 0
(Reset to Factory Off).
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
Lock Timeout
Sets the time after which the door will auto lock.
This parameter has the configuration ID doorlock_timeout
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The YRD240-ZW2 supports 1 association group.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline Lifeline / Alarm / Battery
Association group 1 supports 1 node.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1 | |
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_DOOR_LOCK_V1 | |
COMMAND_CLASS_USER_CODE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V4 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_TIME_V1 | |
COMMAND_CLASS_TIME_PARAMETERS_V1 | |
COMMAND_CLASS_SECURITY_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.