--- layout: documentation title: YRD240-ZW2 - ZWave --- {% include base.html %} # YRD240-ZW2 Yale Assure Lock 2 This describes the Z-Wave device *YRD240-ZW2*, manufactured by *ASSA ABLOY* with the thing type UID of ```yale_yrd240_00_000```. The device is in the category of *Lock*, defining Devices whose primary pupose is locking something. ![YRD240-ZW2 product image](https://opensmarthouse.org/zwavedatabase/1571/image/) The YRD240-ZW2 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices. ## Overview Never worry about carrying around or losing your keys again. The Assure Lock 2 features Z-Wave and seamlessly integrates into 50+ home automation and security systems including SmartThings, Alarm.com, Honeywell, ADT, Wink and more! When added to most Z-Wave™ automation systems, lock and unlock your door, create pin codes, view access history and receive notifications from anywhere. ### Inclusion Information To include the lock in a Z-Wave Network (taken from the installation manual): * On your lock keypad, enter your programming code, followed by the gear icon * Press the 7 key, followed by the gear icon * Press the 1 key, followed by the gear icon ### Exclusion Information To exclude the lock from a Z-Wave Network (taken from the installation manual): * On your lock keypad, enter your programming code, followed by the gear icon * Press the 7 key, followed by the gear icon * Press the 3 key, followed by the gear icon ### General Usage Information Please note that for my lock, YMMV, it is not possible to set the re-lock configurations, these must be set via the Yale app or some other means. The re-lock timing cannot be changed at all, and the re-lock can be changed to off, but not to on. ## Channels The following table summarises the channels available for the YRD240-ZW2 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Door Lock | lock_door | lock_door | Door | Switch | | Alarm (entry) | alarm_entry | alarm_entry | Door | Switch | | Alarm (battery) | alarm_battery | alarm_battery | LowBattery | Switch | | Alarm (raw) | alarm_raw | alarm_raw | | String | | Battery Level | battery-level | system.battery_level | Battery | Number | | Clock Time Offset | time_offset | time_offset | Time | Number | ### Door Lock Lock and unlock the door. The ```lock_door``` channel is of type ```lock_door``` and supports the ```Switch``` item and is in the ```Door``` category. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | ON | Locked | | OFF | Unlocked | ### Alarm (entry) Indicates if the entry alarm is triggered. The ```alarm_entry``` channel is of type ```alarm_entry``` and supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | ON | Open | | OFF | Closed | ### Alarm (battery) Indicates if the low battery alarm is triggered. The ```alarm_battery``` channel is of type ```alarm_battery``` and supports the ```Switch``` item and is in the ```LowBattery``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Alarm (raw) Provides alarm parameters as json string. The ```alarm_raw``` channel is of type ```alarm_raw``` and supports the ```String``` item. This is a read only channel so will only be updated following state changes from the device. This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules. ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```system.battery-level``` channel is of type ```system.battery-level``` and supports the ```Number``` item and is in the ```Battery``` category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%. ### Clock Time Offset Provides the current time difference for the devices time. The ```time_offset``` channel is of type ```time_offset``` and supports the ```Number``` item and is in the ```Time``` category. ## Device Configuration The following table provides a summary of the 11 configuration parameters available in the YRD240-ZW2. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Volume Level | | | 2 | Auto Relock | | | 3 | Auto Relock Time | Auto Relock after 10 to 180 seconds | | 4 | Wrong Code Entry Limit | 3 to 10 attempts allowed | | 5 | Language | | | 7 | Shut Down Time (after wrong code entries) | 10 to 180 seconds before more attempts | | 8 | Operating Mode | | | 11 | One Touch Locking | | | 12 | Privacy Mode | Disables using a passcode to unlock | | 13 | Lock Status LED | | | 15 | Reset to Factory Defaults | Lock will execute Reset To Factory! | | | Lock Timeout | Sets the time after which the door will auto lock | ### Parameter 1: Volume Level The following option values may be configured, in addition to values in the range 1 to 3 -: | Value | Description | |--------|-------------| | 1 | High | | 2 | Low | | 3 | Silent | The manufacturer defined default value is ```2``` (Low). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Auto Relock The following option values may be configured, in addition to values in the range 0 to 0 -: | Value | Description | |--------|-------------| | -1 | Off | | 0 | On | The manufacturer defined default value is ```-1``` (Off). This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: Auto Relock Time Auto Relock after 10 to 180 seconds Values in the range 10 to 180 may be set. The manufacturer defined default value is ```30```. This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Wrong Code Entry Limit 3 to 10 attempts allowed Values in the range 3 to 10 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 5: Language The following option values may be configured, in addition to values in the range 1 to 3 -: | Value | Description | |--------|-------------| | 1 | English | | 2 | Spanish | | 3 | French | The manufacturer defined default value is ```1``` (English). This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 7: Shut Down Time (after wrong code entries) 10 to 180 seconds before more attempts Values in the range 10 to 180 may be set. The manufacturer defined default value is ```60```. This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 8: Operating Mode The following option values may be configured, in addition to values in the range 0 to 3 -: | Value | Description | |--------|-------------| | 0 | Normal Mode | | 1 | Vacation Mode, key only | | 2 | Privacy Mode, no keypad | | 3 | Passage Mode, no auto lock | The manufacturer defined default value is ```0``` (Normal Mode). This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```. ### Parameter 11: One Touch Locking The following option values may be configured, in addition to values in the range 0 to 0 -: | Value | Description | |--------|-------------| | -1 | On | | 0 | Off | The manufacturer defined default value is ```-1``` (On). This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```. ### Parameter 12: Privacy Mode Disables using a passcode to unlock The following option values may be configured, in addition to values in the range 0 to 0 -: | Value | Description | |--------|-------------| | -1 | On | | 0 | Off | The manufacturer defined default value is ```0``` (Off). This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```. ### Parameter 13: Lock Status LED The following option values may be configured, in addition to values in the range 0 to 0 -: | Value | Description | |--------|-------------| | -1 | On | | 0 | Off | The manufacturer defined default value is ```0``` (Off). This parameter has the configuration ID ```config_13_1``` and is of type ```INTEGER```. ### Parameter 15: Reset to Factory Defaults Lock will execute Reset To Factory! This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 0 to 0 -: | Value | Description | |--------|-------------| | -1 | Reset to Factory On | | 0 | Reset to Factory Off | The manufacturer defined default value is ```0``` (Reset to Factory Off). This parameter has the configuration ID ```config_15_1``` and is of type ```INTEGER```. ### Lock Timeout Sets the time after which the door will auto lock. This parameter has the configuration ID ```doorlock_timeout``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The YRD240-ZW2 supports 1 association group. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline Lifeline / Alarm / Battery Association group 1 supports 1 node. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_DOOR_LOCK_LOGGING_V1| | | COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_DOOR_LOCK_V1| | | COMMAND_CLASS_USER_CODE_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V4| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_TIME_V1| | | COMMAND_CLASS_TIME_PARAMETERS_V1| | | COMMAND_CLASS_SECURITY_V1| | ### Documentation Links * [Owners Manual](https://opensmarthouse.org/zwavedatabase/1571/reference/Yale_Assure_Lock_2.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1571).