6.7 KiB
layout | title |
---|---|
documentation | ZSL301EU - ZWave |
{% include base.html %}
ZSL301EU Single relay switch
This describes the Z-Wave device ZSL301EU, manufactured by Team Precision PCL with the thing type UID of precision_zsl301eu_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZSL301EU supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
Switch Link is a power ON/OFF module purposed to control lighting lamps or motor loads.
Inclusion Information
When prompted by your primary controller, press the button
Exclusion Information
When prompted by your primary controller, press the button
Channels
The following table summarises the channels available for the ZSL301EU -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Scene Number | scene_number | scene_number | Number |
Switch
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Scene Number
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
Device Configuration
The following table provides a summary of the 7 configuration parameters available in the ZSL301EU. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
0 | Last Status | Last Status |
1 | Night Light | Night Light |
2 | Enable LED | Enable LED |
3 | Enable All ON/All OFF | Enable All ON/All OFF |
4 | Button Protection | Button Protection |
5 | Delay In Time | Delay In Time |
6 | Delay Out Time | Delay Out Time |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 0: Last Status
Last Status
The following option values may be configured -:
Value | Description |
---|---|
0 | Resume after power outage |
1 | ON after power outage |
2 | OFF after power outage |
The manufacturer defined default value is 0
(Resume after power outage).
This parameter has the configuration ID config_0_1
and is of type INTEGER
.
Parameter 1: Night Light
Night Light
The following option values may be configured -:
Value | Description |
---|---|
0 | LED ON when light ON |
1 | LED ON when light OFF |
The manufacturer defined default value is 1
(LED ON when light OFF).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Enable LED
Enable LED
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable LED |
1 | Enable LED |
The manufacturer defined default value is 1
(Enable LED).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: Enable All ON/All OFF
Enable All ON/All OFF
The following option values may be configured -:
Value | Description |
---|---|
-1 | Enable both All ON and All OFF command |
0 | Disable both All ON and All OFF command. |
1 | Enable only All OFF command. |
2 | Enable only All ON command. |
The manufacturer defined default value is -1
(Enable both All ON and All OFF command).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: Button Protection
Button Protection This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
Value | Description |
---|---|
0 | User can use button for ON/OFF manual control. |
1 | Protect Mode |
2 | Disable button from manual control. |
The manufacturer defined default value is 0
(User can use button for ON/OFF manual control.).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 5: Delay In Time
Delay In Time 0 -> The light will be ON instantaneously once ON command is received.
1 - 5 -> The module will detain the ON process for 1-5 seconds up to user preferences. Values in the range 0 to 5 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter 6: Delay Out Time
Delay Out Time 0 -> The light will be OFF instantaneously once OFF command is received.
1 - 5 -> The module will detain the OFF process for 1-5 seconds up to user preferences. Values in the range 0 to 5 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Documentation Links