--- layout: documentation title: ZSL301EU - ZWave --- {% include base.html %} # ZSL301EU Single relay switch This describes the Z-Wave device *ZSL301EU*, manufactured by *Team Precision PCL* with the thing type UID of ```precision_zsl301eu_00_000```. The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![ZSL301EU product image](https://opensmarthouse.org/zwavedatabase/954/image/) The ZSL301EU supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview Switch Link is a power ON/OFF module purposed to control lighting lamps or motor loads. ### Inclusion Information When prompted by your primary controller, press the button ### Exclusion Information When prompted by your primary controller, press the button ## Channels The following table summarises the channels available for the ZSL301EU -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Switch | switch_binary | switch_binary | Switch | Switch | | Scene Number | scene_number | scene_number | | Number | ### Switch Switch the power on and off. The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item. ## Device Configuration The following table provides a summary of the 7 configuration parameters available in the ZSL301EU. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 0 | Last Status | Last Status | | 1 | Night Light | Night Light | | 2 | Enable LED | Enable LED | | 3 | Enable All ON/All OFF | Enable All ON/All OFF | | 4 | Button Protection | Button Protection | | 5 | Delay In Time | Delay In Time | | 6 | Delay Out Time | Delay Out Time | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 0: Last Status Last Status The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Resume after power outage | | 1 | ON after power outage | | 2 | OFF after power outage | The manufacturer defined default value is ```0``` (Resume after power outage). This parameter has the configuration ID ```config_0_1``` and is of type ```INTEGER```. ### Parameter 1: Night Light Night Light The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | LED ON when light ON | | 1 | LED ON when light OFF | The manufacturer defined default value is ```1``` (LED ON when light OFF). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Enable LED Enable LED The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disable LED | | 1 | Enable LED | The manufacturer defined default value is ```1``` (Enable LED). This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: Enable All ON/All OFF Enable All ON/All OFF The following option values may be configured -: | Value | Description | |--------|-------------| | -1 | Enable both All ON and All OFF command | | 0 | Disable both All ON and All OFF command. | | 1 | Enable only All OFF command. | | 2 | Enable only All ON command. | The manufacturer defined default value is ```-1``` (Enable both All ON and All OFF command). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Button Protection Button Protection This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | User can use button for ON/OFF manual control. | | 1 | Protect Mode | | 2 | Disable button from manual control. | The manufacturer defined default value is ```0``` (User can use button for ON/OFF manual control.). This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 5: Delay In Time Delay In Time 0   ->  The light will be ON instantaneously once ON command is received. 1 - 5   ->  The module will detain the ON process for 1-5 seconds up to user preferences. Values in the range 0 to 5 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 6: Delay Out Time Delay Out Time 0   ->  The light will be OFF instantaneously once OFF command is received. 1 - 5   ->  The module will detain the OFF process for 1-5 seconds up to user preferences. Values in the range 0 to 5 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_6_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The device does not support associations. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_PROTECTION_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [Installation - user manual](https://opensmarthouse.org/zwavedatabase/954/reference/ZSL301EU-manual.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/954).