openhab-docs/_addons_bindings/zwave/doc/philio/pan071a_0_0.md

19 KiB

layout title
documentation Philio PAN07-1A - ZWave

{% include base.html %}

Philio PAN07-1A TWO SPDT Switch module with meter

This describes the Z-Wave device Philio PAN07-1A, manufactured by Philio Technology Corp with the thing type UID of philio_pan071a_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

Philio PAN07-1A product image

The Philio PAN07-1A supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

This in-wall switch module is able to detect Instant power wattage and overload current (6A) of connected light or appliances. When detecting overload state, the Module will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, disconnect and re-connect the Module will reset its overload condition to normal status. 

Inclusion Information

Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode.

Exclusion Information

Pressing INCLUDE_BUTTON three times within 2 seconds will enter exclusion mode. 

Channels

The following table summarises the channels available for the Philio PAN07-1A -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Alarm alarm_general alarm_general Alarm Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Electric meter (power factor) 1 meter_powerfactor1 meter_powerfactor Energy Number
Electric meter (volts) 1 meter_voltage1 meter_voltage Energy Number
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Electric meter (amps) 1 meter_current1 meter_current Energy Number
Switch 2 switch_binary2 switch_binary Switch Switch
Electric meter (power factor) 2 meter_powerfactor2 meter_powerfactor Energy Number
Electric meter (volts) 2 meter_voltage2 meter_voltage Energy Number
Electric meter (kWh) 2 meter_kwh2 meter_kwh Energy Number
Electric meter (watts) 2 meter_watts2 meter_watts Energy Number
Electric meter (amps) 2 meter_current2 meter_current Energy Number
Switch 3 switch_binary3 switch_binary Switch Switch
Electric meter (power factor) 3 meter_powerfactor3 meter_powerfactor Energy Number
Electric meter (volts) 3 meter_voltage3 meter_voltage Energy Number
Electric meter (kWh) 3 meter_kwh3 meter_kwh Energy Number
Electric meter (watts) 3 meter_watts3 meter_watts Energy Number
Electric meter (amps) 3 meter_current3 meter_current Energy Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (power factor)

Indicates the instantaneous power factor.

The meter_powerfactor channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Switch 1

Switch the power on and off.

The switch_binary1 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (power factor) 1

Indicates the instantaneous power factor.

The meter_powerfactor1 channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts) 1

Indicates the instantaneous voltage.

The meter_voltage1 channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 1

Indicates the energy consumption (kWh).

The meter_kwh1 channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 1

Indicates the instantaneous power consumption.

The meter_watts1 channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps) 1

Indicates the instantaneous current consumption.

The meter_current1 channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Switch 2

Switch the power on and off.

The switch_binary2 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (power factor) 2

Indicates the instantaneous power factor.

The meter_powerfactor2 channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts) 2

Indicates the instantaneous voltage.

The meter_voltage2 channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 2

Indicates the energy consumption (kWh).

The meter_kwh2 channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 2

Indicates the instantaneous power consumption.

The meter_watts2 channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps) 2

Indicates the instantaneous current consumption.

The meter_current2 channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Switch 3

Switch the power on and off.

The switch_binary3 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (power factor) 3

Indicates the instantaneous power factor.

The meter_powerfactor3 channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts) 3

Indicates the instantaneous voltage.

The meter_voltage3 channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 3

Indicates the energy consumption (kWh).

The meter_kwh3 channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 3

Indicates the instantaneous power consumption.

The meter_watts3 channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps) 3

Indicates the instantaneous current consumption.

The meter_current3 channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the Philio PAN07-1A. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Watt Meter Report Period Watt Meter Report Period
2 KWH Meter Report KWH Meter Report
3 Selected Relay Selected Relay
4 Mode Mode
5 Threshold of current for Load Caution Threshold of current for Load Caution
6 Threshold of KWH for Load Caution Threshold of KWH for Load Caution
7 Relay control mode Relay control mode
8 Restore Relay state mode Restore Relay state mode
9 Existence of Endpoint3 Existence of Endpoint3
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Watt Meter Report Period

Watt Meter Report Period

 5 second units

Default: 720*5s=3600s=1 hour

If the setting is configured for 1hour (set value =720), the PAN07/PAN09 will report its instant power consumption every 1 hour to the node of correspond Group. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr).  Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 720.

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Parameter 2: KWH Meter Report

KWH Meter Report

10 minute units

default: 6*10min= 1 hour

If the setting is configured for 1hour (set value =6), the PAN07/PAN09 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days) Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 6.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Selected Relay

Selected Relay If Controller not using Multi_Channel command class to access the relay of PAN07/PAN09, you may configure the value of relay to react the Basic Command Class 、Binary Switch Command Class or Meter Command Class V3  The following option values may be configured -:

Value Description
1 Relay1
2 Relay2
3 Relay1 & Relay2

The manufacturer defined default value is 3 (Relay1 & Relay2 ).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Mode

Mode

The following option values may be configured -:

Value Description
1 Edge mode
2 Pulse mode
3 Edge-Toggle mode

The manufacturer defined default value is 1 (Edge mode ).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Threshold of current for Load Caution

Threshold of current for Load Caution

0.01A units

default 600*0.01A = 6.0A

This is a warning when the current of load over the preset threshold value, if the setting value is 600 (6A), when the load current of Relay1 over this value, PAN07/PAN09 will send current meter report to the node of correspond Group, the Range of the setting value is from 10 to 600, and the default value is 600 (6A).  Values in the range 10 to 600 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_5_2 and is of type INTEGER.

Parameter 6: Threshold of KWH for Load Caution

Threshold of KWH for Load Caution This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 or Relay2 over this value, PAN07/PAN09 will send KWh Meter Report command to the node of correspond Group, minimum value is 1KWh and default value is 10000 kWh Values in the range 1 to 10000 may be set.

The manufacturer defined default value is 10000.

This parameter has the configuration ID config_6_2 and is of type INTEGER.

Parameter 7: Relay control mode

Relay control mode

The following option values may be configured -:

Value Description
1 Control relay refer to meter wattage
2 Control relay directly

The manufacturer defined default value is 1 (Control relay refer to meter wattage ).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Restore Relay state mode

Restore Relay state mode

The following option values may be configured -:

Value Description
0 All relay stay NC terminal
1 Last relay switch state
2 All relay stay NO terminal

The manufacturer defined default value is 1 (Last relay switch state ).

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Existence of Endpoint3

Existence of Endpoint3 The endpoint3 of Multi-Channel Command Class is related to relay1 and relay2. It may be redundant for the need to control relay1 or relay2 individually. When the Existence of Endpoint3 is set as 0, the endpoint3 of Multi-Channel Command Class will be disabled. The default value is 1 The following option values may be configured -:

Value Description
1 Endpoint3 exist
2 No Endpoint3

The manufacturer defined default value is 1 ( Endpoint3 exist).

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The Philio PAN07-1A supports 3 association groups.

Group 1: Group 1

For group 1, the Switch will report (1) ON/OFF status of Relay1 and Relay2 (2) Instant Power Consumption (Watt) of Relay1 and Relay2 (3) Accumulated Power Consumption (KWh) of Relay1 and Relay2 to Z-Wave Controller.  

Association group 1 supports 1 node.

Group 2: Group 2

For group 2, the Switch will report (1) ON/OFF status of Relay1 (2) Instant Power Consumption (Watt) of Relay1 (3) Accumulated Power Consumption (KWh) of Relay1 to Z-Wave Controller. 

Association group 2 supports 1 node.

Group 3: Group 3

For group 3, the Switch will report (1) ON/OFF status of Relay2 (2) Instant Power Consumption (Watt) of Relay2 (3) Accumulated Power Consumption (KWh) of Relay2 to Z-Wave Controller. 

Association group 3 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3

Endpoint 3

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.