--- layout: documentation title: Philio PAN07-1A - ZWave --- {% include base.html %} # Philio PAN07-1A TWO SPDT Switch module with meter This describes the Z-Wave device *Philio PAN07-1A*, manufactured by *[Philio Technology Corp](http://www.philio-tech.com/)* with the thing type UID of ```philio_pan071a_00_000```. The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![Philio PAN07-1A product image](https://opensmarthouse.org/zwavedatabase/629/image/) The Philio PAN07-1A supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview This in-wall switch module is able to detect Instant power wattage and overload current (6A) of connected light or appliances. When detecting overload state, the Module will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, disconnect and re-connect the Module will reset its overload condition to normal status.  ### Inclusion Information Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode. ### Exclusion Information Pressing INCLUDE_BUTTON three times within 2 seconds will enter exclusion mode.  ## Channels The following table summarises the channels available for the Philio PAN07-1A -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Switch | switch_binary | switch_binary | Switch | Switch | | Electric meter (power factor) | meter_powerfactor | meter_powerfactor | Energy | Number | | Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number | | Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number | | Electric meter (watts) | meter_watts | meter_watts | Energy | Number | | Electric meter (amps) | meter_current | meter_current | Energy | Number | | Alarm | alarm_general | alarm_general | Alarm | Switch | | Switch 1 | switch_binary1 | switch_binary | Switch | Switch | | Electric meter (power factor) 1 | meter_powerfactor1 | meter_powerfactor | Energy | Number | | Electric meter (volts) 1 | meter_voltage1 | meter_voltage | Energy | Number | | Electric meter (kWh) 1 | meter_kwh1 | meter_kwh | Energy | Number | | Electric meter (watts) 1 | meter_watts1 | meter_watts | Energy | Number | | Electric meter (amps) 1 | meter_current1 | meter_current | Energy | Number | | Switch 2 | switch_binary2 | switch_binary | Switch | Switch | | Electric meter (power factor) 2 | meter_powerfactor2 | meter_powerfactor | Energy | Number | | Electric meter (volts) 2 | meter_voltage2 | meter_voltage | Energy | Number | | Electric meter (kWh) 2 | meter_kwh2 | meter_kwh | Energy | Number | | Electric meter (watts) 2 | meter_watts2 | meter_watts | Energy | Number | | Electric meter (amps) 2 | meter_current2 | meter_current | Energy | Number | | Switch 3 | switch_binary3 | switch_binary | Switch | Switch | | Electric meter (power factor) 3 | meter_powerfactor3 | meter_powerfactor | Energy | Number | | Electric meter (volts) 3 | meter_voltage3 | meter_voltage | Energy | Number | | Electric meter (kWh) 3 | meter_kwh3 | meter_kwh | Energy | Number | | Electric meter (watts) 3 | meter_watts3 | meter_watts | Energy | Number | | Electric meter (amps) 3 | meter_current3 | meter_current | Energy | Number | ### Switch Switch the power on and off. The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Electric meter (power factor) Indicates the instantaneous power factor. The ```meter_powerfactor``` channel is of type ```meter_powerfactor``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) Indicates the instantaneous voltage. The ```meter_voltage``` channel is of type ```meter_voltage``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel is of type ```meter_kwh``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts``` channel is of type ```meter_watts``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) Indicates the instantaneous current consumption. The ```meter_current``` channel is of type ```meter_current``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Alarm Indicates if an alarm is triggered. The ```alarm_general``` channel is of type ```alarm_general``` and supports the ```Switch``` item and is in the ```Alarm``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Switch 1 Switch the power on and off. The ```switch_binary1``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Electric meter (power factor) 1 Indicates the instantaneous power factor. The ```meter_powerfactor1``` channel is of type ```meter_powerfactor``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) 1 Indicates the instantaneous voltage. The ```meter_voltage1``` channel is of type ```meter_voltage``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) 1 Indicates the energy consumption (kWh). The ```meter_kwh1``` channel is of type ```meter_kwh``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (watts) 1 Indicates the instantaneous power consumption. The ```meter_watts1``` channel is of type ```meter_watts``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) 1 Indicates the instantaneous current consumption. The ```meter_current1``` channel is of type ```meter_current``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Switch 2 Switch the power on and off. The ```switch_binary2``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Electric meter (power factor) 2 Indicates the instantaneous power factor. The ```meter_powerfactor2``` channel is of type ```meter_powerfactor``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) 2 Indicates the instantaneous voltage. The ```meter_voltage2``` channel is of type ```meter_voltage``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) 2 Indicates the energy consumption (kWh). The ```meter_kwh2``` channel is of type ```meter_kwh``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (watts) 2 Indicates the instantaneous power consumption. The ```meter_watts2``` channel is of type ```meter_watts``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) 2 Indicates the instantaneous current consumption. The ```meter_current2``` channel is of type ```meter_current``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Switch 3 Switch the power on and off. The ```switch_binary3``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Electric meter (power factor) 3 Indicates the instantaneous power factor. The ```meter_powerfactor3``` channel is of type ```meter_powerfactor``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) 3 Indicates the instantaneous voltage. The ```meter_voltage3``` channel is of type ```meter_voltage``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (kWh) 3 Indicates the energy consumption (kWh). The ```meter_kwh3``` channel is of type ```meter_kwh``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (watts) 3 Indicates the instantaneous power consumption. The ```meter_watts3``` channel is of type ```meter_watts``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) 3 Indicates the instantaneous current consumption. The ```meter_current3``` channel is of type ```meter_current``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ## Device Configuration The following table provides a summary of the 9 configuration parameters available in the Philio PAN07-1A. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Watt Meter Report Period | Watt Meter Report Period | | 2 | KWH Meter Report | KWH Meter Report | | 3 | Selected Relay | Selected Relay | | 4 | Mode | Mode | | 5 | Threshold of current for Load Caution | Threshold of current for Load Caution | | 6 | Threshold of KWH for Load Caution | Threshold of KWH for Load Caution | | 7 | Relay control mode | Relay control mode | | 8 | Restore Relay state mode | Restore Relay state mode | | 9 | Existence of Endpoint3 | Existence of Endpoint3 | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 1: Watt Meter Report Period Watt Meter Report Period #  5 second units Default: 720*5s=3600s=1 hour If the setting is configured for 1hour (set value =720), the PAN07/PAN09 will report its instant power consumption every 1 hour to the node of correspond Group. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr).  Values in the range 1 to 32767 may be set. The manufacturer defined default value is ```720```. This parameter has the configuration ID ```config_1_2``` and is of type ```INTEGER```. ### Parameter 2: KWH Meter Report KWH Meter Report # 10 minute units default: 6*10min= 1 hour If the setting is configured for 1hour (set value =6), the PAN07/PAN09 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days) Values in the range 1 to 32767 may be set. The manufacturer defined default value is ```6```. This parameter has the configuration ID ```config_2_2``` and is of type ```INTEGER```. ### Parameter 3: Selected Relay Selected Relay If Controller not using Multi_Channel command class to access the relay of PAN07/PAN09, you may configure the value of relay to react the Basic Command Class 、Binary Switch Command Class or Meter Command Class V3  The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | Relay1 | | 2 | Relay2 | | 3 | Relay1 & Relay2 | The manufacturer defined default value is ```3``` (Relay1 & Relay2 ). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Mode Mode The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | Edge mode | | 2 | Pulse mode | | 3 | Edge-Toggle mode | The manufacturer defined default value is ```1``` (Edge mode ). This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 5: Threshold of current for Load Caution Threshold of current for Load Caution # 0.01A units default 600*0.01A = 6.0A This is a warning when the current of load over the preset threshold value, if the setting value is 600 (6A), when the load current of Relay1 over this value, PAN07/PAN09 will send current meter report to the node of correspond Group, the Range of the setting value is from 10 to 600, and the default value is 600 (6A).  Values in the range 10 to 600 may be set. The manufacturer defined default value is ```600```. This parameter has the configuration ID ```config_5_2``` and is of type ```INTEGER```. ### Parameter 6: Threshold of KWH for Load Caution Threshold of KWH for Load Caution This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 or Relay2 over this value, PAN07/PAN09 will send KWh Meter Report command to the node of correspond Group, minimum value is 1KWh and default value is 10000 kWh Values in the range 1 to 10000 may be set. The manufacturer defined default value is ```10000```. This parameter has the configuration ID ```config_6_2``` and is of type ```INTEGER```. ### Parameter 7: Relay control mode Relay control mode The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | Control relay refer to meter wattage | | 2 | Control relay directly | The manufacturer defined default value is ```1``` (Control relay refer to meter wattage ). This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 8: Restore Relay state mode Restore Relay state mode The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | All relay stay NC terminal | | 1 | Last relay switch state | | 2 | All relay stay NO terminal | The manufacturer defined default value is ```1``` (Last relay switch state ). This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```. ### Parameter 9: Existence of Endpoint3 Existence of Endpoint3 The endpoint3 of Multi-Channel Command Class is related to relay1 and relay2. It may be redundant for the need to control relay1 or relay2 individually. When the Existence of Endpoint3 is set as 0, the endpoint3 of Multi-Channel Command Class will be disabled. The default value is 1 The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | Endpoint3 exist | | 2 | No Endpoint3 | The manufacturer defined default value is ```1``` ( Endpoint3 exist). This parameter has the configuration ID ```config_9_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The Philio PAN07-1A supports 3 association groups. ### Group 1: Group 1 For group 1, the Switch will report (1) ON/OFF status of Relay1 and Relay2 (2) Instant Power Consumption (Watt) of Relay1 and Relay2 (3) Accumulated Power Consumption (KWh) of Relay1 and Relay2 to Z-Wave Controller.   Association group 1 supports 1 node. ### Group 2: Group 2 For group 2, the Switch will report (1) ON/OFF status of Relay1 (2) Instant Power Consumption (Watt) of Relay1 (3) Accumulated Power Consumption (KWh) of Relay1 to Z-Wave Controller.  Association group 2 supports 1 node. ### Group 3: Group 3 For group 3, the Switch will report (1) ON/OFF status of Relay2 (2) Instant Power Consumption (Watt) of Relay2 (3) Accumulated Power Consumption (KWh) of Relay2 to Z-Wave Controller.  Association group 3 supports 1 node. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | #### Endpoint 1 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_METER_V3| | #### Endpoint 2 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_METER_V3| | #### Endpoint 3 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_METER_V3| | ### Documentation Links * [User Manual](https://opensmarthouse.org/zwavedatabase/629/reference/311664-PAN07-1-2-3A-manual-20141028.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/629).