PAB04 Smart Energy Flow Meter

This describes the Z-Wave device PAB04, manufactured by Philio Technology Corp with the thing type UID of philio_pab04_00_000.

The device is in the category of Valve, defining Valves used to control water or gas. e.g. a flow stop valve..

PAB04 product image

The PAB04 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

This valves controller PAB04 is a security enabled wireless switch, based on Z-Wave Plus technology. 

Connect PAB04 with an external water meter which can output pulse signals. PAB04 is able to detect instance water flow and the accumulated water.

Inclusion Information

Pressing On/Off button three times within 2 seconds will enter inclusion mode.

Exclusion Information

Pressing On/Off button three times within 2 seconds will enter exclusion mode.

General Usage Information

Channels

The following table summarises the channels available for the PAB04 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Sensor (WATER_FLOW) water_flow water_flow
Water meter (gal) meter_water_gallons meter_water_gallons Water Number
Water meter (m3) meter_water_cubic_meters meter_water_cubic_meters Water Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Sensor (WATER_FLOW)

Channel type information on this channel is not found.

Water meter (gal)

Indicates the instantaneous water consumption.

The meter_water_gallons channel is of type meter_water_gallons and supports the Number item and is in the Water category. This is a read only channel so will only be updated following state changes from the device.

Water meter (m3)

Indicates the instantaneous water consumption.

The meter_water_cubic_meters channel is of type meter_water_cubic_meters and supports the Number item and is in the Water category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 6 configuration parameters available in the PAB04. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Unit of Water Flow Unit of Water Flow
2 Accumulated Water Report Accumulated Water Report
3 Instant Water Flow Percent Reported Instant Water Flow Percent Reported
4 Pulses per Liter Pulses per Liter
5 Relay Control Mode Relay Control Mode
6 Periodic Auto Report Timer Periodic Auto Report Timer

Parameter 1: Unit of Water Flow

Unit of Water Flow

The following option values may be configured, in addition to values in the range 1 to 2 -:

Value Description
1 US Gallon
2 KL

The manufacturer defined default value is 2 (KL).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Accumulated Water Report

Accumulated Water Report

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Disable Report
1 Enable Report

The manufacturer defined default value is 1 (Enable Report).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Instant Water Flow Percent Reported

Instant Water Flow Percent Reported

The following option values may be configured -:

Value Description
0 Disabled

The manufacturer defined default value is 10.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Pulses per Liter

Pulses per Liter This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 32676 may be set.

The manufacturer defined default value is 450.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: Relay Control Mode

Relay Control Mode

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Normally Closed
1 Normally Open

The manufacturer defined default value is 0 (Normally Closed).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Periodic Auto Report Timer

Periodic Auto Report Timer

The following option values may be configured -:

Value Description
0 Disabled

The manufacturer defined default value is 60.

This parameter has the configuration ID config_6_2 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The PAB04 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V9
COMMAND_CLASS_METER_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SECURITY_V1

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.