--- layout: documentation title: PAB04 - ZWave --- {% include base.html %} # PAB04 Smart Energy Flow Meter This describes the Z-Wave device *PAB04*, manufactured by *[Philio Technology Corp](http://www.philio-tech.com/)* with the thing type UID of ```philio_pab04_00_000```. The device is in the category of *Valve*, defining Valves used to control water or gas. e.g. a flow stop valve.. ![PAB04 product image](https://opensmarthouse.org/zwavedatabase/1224/image/) The PAB04 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview This valves controller PAB04 is a security enabled wireless switch, based on Z-Wave Plus technology.  Connect PAB04 with an external water meter which can output pulse signals. PAB04 is able to detect instance water flow and the accumulated water. ### Inclusion Information Pressing On/Off button three times within 2 seconds will enter inclusion mode. ### Exclusion Information Pressing On/Off button three times within 2 seconds will enter exclusion mode. ### General Usage Information ## Channels The following table summarises the channels available for the PAB04 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Switch | switch_binary | switch_binary | Switch | Switch | | Sensor (WATER_FLOW) | water_flow | water_flow | | | | Water meter (gal) | meter_water_gallons | meter_water_gallons | Water | Number | | Water meter (m3) | meter_water_cubic_meters | meter_water_cubic_meters | Water | Number | ### Switch Switch the power on and off. The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Sensor (WATER_FLOW) Channel type information on this channel is not found. ### Water meter (gal) Indicates the instantaneous water consumption. The ```meter_water_gallons``` channel is of type ```meter_water_gallons``` and supports the ```Number``` item and is in the ```Water``` category. This is a read only channel so will only be updated following state changes from the device. ### Water meter (m3) Indicates the instantaneous water consumption. The ```meter_water_cubic_meters``` channel is of type ```meter_water_cubic_meters``` and supports the ```Number``` item and is in the ```Water``` category. This is a read only channel so will only be updated following state changes from the device. ## Device Configuration The following table provides a summary of the 6 configuration parameters available in the PAB04. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Unit of Water Flow | Unit of Water Flow | | 2 | Accumulated Water Report | Accumulated Water Report | | 3 | Instant Water Flow Percent Reported | Instant Water Flow Percent Reported | | 4 | Pulses per Liter | Pulses per Liter | | 5 | Relay Control Mode | Relay Control Mode | | 6 | Periodic Auto Report Timer | Periodic Auto Report Timer | ### Parameter 1: Unit of Water Flow Unit of Water Flow The following option values may be configured, in addition to values in the range 1 to 2 -: | Value | Description | |--------|-------------| | 1 | US Gallon | | 2 | KL | The manufacturer defined default value is ```2``` (KL). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Accumulated Water Report Accumulated Water Report The following option values may be configured, in addition to values in the range 0 to 1 -: | Value | Description | |--------|-------------| | 0 | Disable Report | | 1 | Enable Report | The manufacturer defined default value is ```1``` (Enable Report). This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: Instant Water Flow Percent Reported Instant Water Flow Percent Reported The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | The manufacturer defined default value is ```10```. This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Pulses per Liter Pulses per Liter This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 32676 may be set. The manufacturer defined default value is ```450```. This parameter has the configuration ID ```config_4_2``` and is of type ```INTEGER```. ### Parameter 5: Relay Control Mode Relay Control Mode The following option values may be configured, in addition to values in the range 0 to 1 -: | Value | Description | |--------|-------------| | 0 | Normally Closed | | 1 | Normally Open | The manufacturer defined default value is ```0``` (Normally Closed). This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 6: Periodic Auto Report Timer Periodic Auto Report Timer The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disabled | The manufacturer defined default value is ```60```. This parameter has the configuration ID ```config_6_2``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The PAB04 supports 1 association group. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 supports 1 node. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V9| | | COMMAND_CLASS_METER_V2| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_SECURITY_V1| | ### Documentation Links * [Manual](https://opensmarthouse.org/zwavedatabase/1224/reference/PAB04_manual-V2-20200219.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1224).