4512757 Z-Wave thermostat
This describes the Z-Wave device 4512757, manufactured by Namron with the thing type UID of namron_4512757_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The 4512757 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
Z-Wave 16A heating (or cooling) wall thermostat with four regular buttons below the display. Internal, external and floor temperature sensors are supported.
Inclusion Information
Press M-key for 10 seconds to enter settings mode. Press up/down arrow keys to select "NET". Short press M-key, should show "IN". Press M-key for 2 seconds to start inclusion, display will show "i..." .
Exclusion Information
Press M-key for 10 seconds to enter settings mode. Press up/down arrow keys to select "NET". Short press M-key, should show "OUT." Press M-key for 2 seconds to start inclusion, display will show "o..." .
General Usage Information
Note that the exclusion mode "OUT" is not perfect. Also, factory reset does not seem to forget a network inclusion.
Channels
The following table summarises the channels available for the 4512757 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
Operating State | thermostat_state | thermostat_state | Temperature | Number |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (cooling) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Alarm (access) | alarm_access | alarm_access | Door | Switch |
Alarm (power) | alarm_power | alarm_power | Energy | Switch |
Alarm (system) | alarm_system | alarm_system | Switch | |
Clock Time Offset | time_offset | time_offset | Time | Number |
Switch
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Sensor (temperature)
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Electric meter (kWh)
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (watts)
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (volts)
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (amps)
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Thermostat mode
Sets the thermostat.
The thermostat_mode
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Operating State
Sets the thermostat operating state.
The thermostat_state
channel is of type thermostat_state
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Setpoint (heating)
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Setpoint (cooling)
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Alarm (access)
Indicates if the access control alarm is triggered.
The alarm_access
channel is of type alarm_access
and supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Alarm (power)
Indicates if a power alarm is triggered.
The alarm_power
channel is of type alarm_power
and supports the Switch
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Alarm (system)
Indicates if a system alarm is triggered.
The alarm_system
channel is of type alarm_system
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Clock Time Offset
Provides the current time difference for the devices time.
The time_offset
channel is of type time_offset
and supports the Number
item and is in the Time
category.
Device Configuration
The following table provides a summary of the 26 configuration parameters available in the 4512757. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
4 | Eco Mode | Enable ECO mode |
8 | Window Check | Enable window open detection |
10 | Frost Enable | Enable frost detection and prevention feature. Note that enabling this mode overrides normal thermostat mode and forces the setpoint to the frost limit, so this mode should usually be left disabled. |
23 | Temp Unit | Select unit for temperature |
27 | Temp Correction | Temperature correction/calibration; in 1/10 °C |
31 | Work Days Set | For week program mode, set which are working days |
40 | Child Lock | Enable child lock mode where panel buttons are ignored |
43 | Sensor Mode | Select which sensors to use |
58 | Run Mode | Select between manual mode or weekly program |
112 | Adaptation | Enable adaptation mode, self adjusting |
118 | Regulator | Specify heating schedule time; in minutes, 0 to turn off |
123 | LCD Backlight Standby | LCD backlight brightness in standby mode; in % |
124 | LCD Backligh Work | LCD backlight brightness in working mode; in % |
127 | Regulator Percentage | Regulator percentage; in % |
134 | Dif Celcius | Regulator temperature hysteresis, Celcius mode; in 1/10 °C (step 5) |
135 | Dif Fahrenheit | Regulator termperature hysteresis, Fahrenheit mode; in 1/10 °F (step 10) |
136 | Frost Celsius | Frost limit in Celcius mode; in 1/10 °C (step 10) |
137 | Frost Fahrenheit | Frost limit in Fahrenheit mode; 1/10 °F (step 20) |
183 | Drying Time | Drying time; in minutes (step 5), 0 for off |
185 | Celcius Floor Limit | Floor limit temperature in Celcius mode; in 1/10 °C (step 50) |
186 | Fahrenheit Floor Limit | Floor limit temperature in Fahrenheit mode; in 1/10 °F (step 10) |
187 | LCD Display Switch | LCD display switch |
188 | Automatically Get Network Time | Automatically get network time |
199 | Week Program Time | Four byte fields, see manual |
200 | Week Program Celsius | Four byte fields, see manual |
201 | Week Program Fahrenheit | Four byte fields, see manual |
Parameter 4: Eco Mode
Enable ECO mode
The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | Off |
1 | On |
The manufacturer defined default value is 0
(Off).
This parameter has the configuration ID config_4_4
and is of type INTEGER
.
Parameter 8: Window Check
Enable window open detection
The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | Off |
1 | On |
The manufacturer defined default value is 1
(On).
This parameter has the configuration ID config_8_4
and is of type INTEGER
.
Parameter 10: Frost Enable
Enable frost detection and prevention feature. Note that enabling this mode overrides normal thermostat mode and forces the setpoint to the frost limit, so this mode should usually be left disabled.
The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | Off |
1 | On |
The manufacturer defined default value is 0
(Off).
This parameter has the configuration ID config_10_4
and is of type INTEGER
.
Parameter 23: Temp Unit
Select unit for temperature
The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | °C |
1 | °F |
The manufacturer defined default value is 0
(°C).
This parameter has the configuration ID config_23_0
and is of type INTEGER
.
Parameter 27: Temp Correction
Temperature correction/calibration; in 1/10 °C
Values in the range -10 to 10 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_27_4
and is of type INTEGER
.
Parameter 31: Work Days Set
For week program mode, set which are working days This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 0 to 3 -:
Value | Description |
---|---|
0 | 12345/67 |
1 | 123456/7 |
2 | /1234567 |
3 | 1234567/ |
The manufacturer defined default value is 0
(12345/67).
This parameter has the configuration ID config_31_4
and is of type INTEGER
.
Parameter 40: Child Lock
Enable child lock mode where panel buttons are ignored
The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | Off |
1 | On |
The manufacturer defined default value is 0
(Off).
This parameter has the configuration ID config_40_4
and is of type INTEGER
.
Parameter 43: Sensor Mode
Select which sensors to use
The following option values may be configured, in addition to values in the range 0 to 6 -:
Value | Description |
---|---|
0 | Internal sensor |
1 | Floor sensor |
2 | Internal sensor with floor temperature limit |
3 | External sensor |
4 | External sensor with floor temperature limit |
5 | Do not use |
6 | Controller heating percentage |
The manufacturer defined default value is 1
(Floor sensor).
This parameter has the configuration ID config_43_4
and is of type INTEGER
.
Parameter 58: Run Mode
Select between manual mode or weekly program
The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | Manual |
1 | Program |
The manufacturer defined default value is 1
(Program).
This parameter has the configuration ID config_58_4
and is of type INTEGER
.
Parameter 112: Adaptation
Enable adaptation mode, self adjusting
The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | Off |
1 | On |
The manufacturer defined default value is 0
(Off).
This parameter has the configuration ID config_112_4
and is of type INTEGER
.
Parameter 118: Regulator
Specify heating schedule time; in minutes, 0 to turn off
The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_118_4
and is of type INTEGER
.
Parameter 123: LCD Backlight Standby
LCD backlight brightness in standby mode; in %
Values in the range 10 to 100 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_123_4
and is of type INTEGER
.
Parameter 124: LCD Backligh Work
LCD backlight brightness in working mode; in %
Values in the range 10 to 100 may be set.
The manufacturer defined default value is 100
.
This parameter has the configuration ID config_124_4
and is of type INTEGER
.
Parameter 127: Regulator Percentage
Regulator percentage; in %
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 20
.
This parameter has the configuration ID config_127_4
and is of type INTEGER
.
Parameter 134: Dif Celcius
Regulator temperature hysteresis, Celcius mode; in 1/10 °C (step 5)
Values in the range 5 to 100 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_134_4
and is of type INTEGER
.
Parameter 135: Dif Fahrenheit
Regulator termperature hysteresis, Fahrenheit mode; in 1/10 °F (step 10)
Values in the range 10 to 180 may be set.
The manufacturer defined default value is 20
.
This parameter has the configuration ID config_135_4
and is of type INTEGER
.
Parameter 136: Frost Celsius
Frost limit in Celcius mode; in 1/10 °C (step 10)
Values in the range 50 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_136_0
and is of type INTEGER
.
Parameter 137: Frost Fahrenheit
Frost limit in Fahrenheit mode; 1/10 °F (step 20)
Values in the range 410 to 510 may be set.
The manufacturer defined default value is 410
.
This parameter has the configuration ID config_137_4
and is of type INTEGER
.
Parameter 183: Drying Time
Drying time; in minutes (step 5), 0 for off
The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_183_4
and is of type INTEGER
.
Parameter 185: Celcius Floor Limit
Floor limit temperature in Celcius mode; in 1/10 °C (step 50)
Values in the range 50 to 600 may be set.
The manufacturer defined default value is 270
.
This parameter has the configuration ID config_185_4
and is of type INTEGER
.
Parameter 186: Fahrenheit Floor Limit
Floor limit temperature in Fahrenheit mode; in 1/10 °F (step 10)
Values in the range 410 to 1400 may be set.
The manufacturer defined default value is 810
.
This parameter has the configuration ID config_186_4
and is of type INTEGER
.
Parameter 187: LCD Display Switch
LCD display switch
The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | Off |
1 | On |
The manufacturer defined default value is 1
(On).
This parameter has the configuration ID config_187_4
and is of type INTEGER
.
Parameter 188: Automatically Get Network Time
Automatically get network time
The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | Off |
1 | On |
The manufacturer defined default value is 0
(Off).
This parameter has the configuration ID config_188_4
and is of type INTEGER
.
Parameter 199: Week Program Time
Four byte fields, see manual This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_199_4
and is of type INTEGER
.
Parameter 200: Week Program Celsius
Four byte fields, see manual This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_200_4
and is of type INTEGER
.
Parameter 201: Week Program Fahrenheit
Four byte fields, see manual This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_201_4
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 4512757 supports 1 association group.
Group 1:
Report Available commands:
**DEVICE_RESET_LOCALLY_NOTIFICATION
SENSOR_MULTILEVEL_REPORT
BINARY_SWITCH_REPORT
NOTIFICATION_REPORT
CONFIGURATION_REPORT
THERMOSTAT_MODE_REPORT
THERMOSTAT_SETPOINT_REPORT
PROTECTION_REPORT
METER_REPORT
COMMAND_CLASS_INDICATOR
**
Association group 1 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V10 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_TRANSPORT_SERVICE_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_SUPERVISION_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V8 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_PROTECTION_V2 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_INDICATOR_V3 | |
COMMAND_CLASS_TIME_V1 | |
COMMAND_CLASS_TIME_PARAMETERS_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | |
COMMAND_CLASS_SECURITY_V1 | |
COMMAND_CLASS_SECURITY_2_V1 |