4512757 Z-Wave thermostat

This describes the Z-Wave device 4512757, manufactured by Namron with the thing type UID of namron_4512757_00_000.

The device is in the category of HVAC, defining Air condition devices, Fans.

4512757 product image

The 4512757 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Z-Wave 16A heating (or cooling) wall thermostat with four regular buttons below the display. Internal, external and floor temperature sensors are supported.

Inclusion Information

Press M-key for 10 seconds to enter settings mode. Press up/down arrow keys to select "NET". Short press M-key, should show "IN". Press M-key for 2 seconds to start inclusion, display will show "i..." .

Exclusion Information

Press M-key for 10 seconds to enter settings mode. Press up/down arrow keys to select "NET". Short press M-key, should show "OUT." Press M-key for 2 seconds to start inclusion, display will show "o..." .

General Usage Information

Note that the exclusion mode "OUT" is not perfect. Also, factory reset does not seem to forget a network inclusion.

Channels

The following table summarises the channels available for the 4512757 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Operating State thermostat_state thermostat_state Temperature Number
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (cooling) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Alarm (access) alarm_access alarm_access Door Switch
Alarm (power) alarm_power alarm_power Energy Switch
Alarm (system) alarm_system alarm_system Switch
Clock Time Offset time_offset time_offset Time Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Operating State

Sets the thermostat operating state.

The thermostat_state channel is of type thermostat_state and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (cooling)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Alarm (access)

Indicates if the access control alarm is triggered.

The alarm_access channel is of type alarm_access and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (system)

Indicates if a system alarm is triggered.

The alarm_system channel is of type alarm_system and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel is of type time_offset and supports the Number item and is in the Time category.

Device Configuration

The following table provides a summary of the 26 configuration parameters available in the 4512757. Detailed information on each parameter can be found in the sections below.

Param Name Description
4 Eco Mode Enable ECO mode
8 Window Check Enable window open detection
10 Frost Enable Enable frost detection and prevention feature. Note that enabling this mode overrides normal thermostat mode and forces the setpoint to the frost limit, so this mode should usually be left disabled.
23 Temp Unit Select unit for temperature
27 Temp Correction Temperature correction/calibration; in 1/10 °C
31 Work Days Set For week program mode, set which are working days
40 Child Lock Enable child lock mode where panel buttons are ignored
43 Sensor Mode Select which sensors to use
58 Run Mode Select between manual mode or weekly program
112 Adaptation Enable adaptation mode, self adjusting
118 Regulator Specify heating schedule time; in minutes, 0 to turn off
123 LCD Backlight Standby LCD backlight brightness in standby mode; in %
124 LCD Backligh Work LCD backlight brightness in working mode; in %
127 Regulator Percentage Regulator percentage; in %
134 Dif Celcius Regulator temperature hysteresis, Celcius mode; in 1/10 °C (step 5)
135 Dif Fahrenheit Regulator termperature hysteresis, Fahrenheit mode; in 1/10 °F (step 10)
136 Frost Celsius Frost limit in Celcius mode; in 1/10 °C (step 10)
137 Frost Fahrenheit Frost limit in Fahrenheit mode; 1/10 °F (step 20)
183 Drying Time Drying time; in minutes (step 5), 0 for off
185 Celcius Floor Limit Floor limit temperature in Celcius mode; in 1/10 °C (step 50)
186 Fahrenheit Floor Limit Floor limit temperature in Fahrenheit mode; in 1/10 °F (step 10)
187 LCD Display Switch LCD display switch
188 Automatically Get Network Time Automatically get network time
199 Week Program Time Four byte fields, see manual
200 Week Program Celsius Four byte fields, see manual
201 Week Program Fahrenheit Four byte fields, see manual

Parameter 4: Eco Mode

Enable ECO mode

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Off
1 On

The manufacturer defined default value is 0 (Off).

This parameter has the configuration ID config_4_4 and is of type INTEGER.

Parameter 8: Window Check

Enable window open detection

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Off
1 On

The manufacturer defined default value is 1 (On).

This parameter has the configuration ID config_8_4 and is of type INTEGER.

Parameter 10: Frost Enable

Enable frost detection and prevention feature. Note that enabling this mode overrides normal thermostat mode and forces the setpoint to the frost limit, so this mode should usually be left disabled.

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Off
1 On

The manufacturer defined default value is 0 (Off).

This parameter has the configuration ID config_10_4 and is of type INTEGER.

Parameter 23: Temp Unit

Select unit for temperature

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 °C
1 °F

The manufacturer defined default value is 0 (°C).

This parameter has the configuration ID config_23_0 and is of type INTEGER.

Parameter 27: Temp Correction

Temperature correction/calibration; in 1/10 °C

Values in the range -10 to 10 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_27_4 and is of type INTEGER.

Parameter 31: Work Days Set

For week program mode, set which are working days This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 0 to 3 -:

Value Description
0 12345/67
1 123456/7
2 /1234567
3 1234567/

The manufacturer defined default value is 0 (12345/67).

This parameter has the configuration ID config_31_4 and is of type INTEGER.

Parameter 40: Child Lock

Enable child lock mode where panel buttons are ignored

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Off
1 On

The manufacturer defined default value is 0 (Off).

This parameter has the configuration ID config_40_4 and is of type INTEGER.

Parameter 43: Sensor Mode

Select which sensors to use

The following option values may be configured, in addition to values in the range 0 to 6 -:

Value Description
0 Internal sensor
1 Floor sensor
2 Internal sensor with floor temperature limit
3 External sensor
4 External sensor with floor temperature limit
5 Do not use
6 Controller heating percentage

The manufacturer defined default value is 1 (Floor sensor).

This parameter has the configuration ID config_43_4 and is of type INTEGER.

Parameter 58: Run Mode

Select between manual mode or weekly program

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Manual
1 Program

The manufacturer defined default value is 1 (Program).

This parameter has the configuration ID config_58_4 and is of type INTEGER.

Parameter 112: Adaptation

Enable adaptation mode, self adjusting

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Off
1 On

The manufacturer defined default value is 0 (Off).

This parameter has the configuration ID config_112_4 and is of type INTEGER.

Parameter 118: Regulator

Specify heating schedule time; in minutes, 0 to turn off

The following option values may be configured -:

Value Description
0 Off

The manufacturer defined default value is 30.

This parameter has the configuration ID config_118_4 and is of type INTEGER.

Parameter 123: LCD Backlight Standby

LCD backlight brightness in standby mode; in %

Values in the range 10 to 100 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_123_4 and is of type INTEGER.

Parameter 124: LCD Backligh Work

LCD backlight brightness in working mode; in %

Values in the range 10 to 100 may be set.

The manufacturer defined default value is 100.

This parameter has the configuration ID config_124_4 and is of type INTEGER.

Parameter 127: Regulator Percentage

Regulator percentage; in %

Values in the range 0 to 100 may be set.

The manufacturer defined default value is 20.

This parameter has the configuration ID config_127_4 and is of type INTEGER.

Parameter 134: Dif Celcius

Regulator temperature hysteresis, Celcius mode; in 1/10 °C (step 5)

Values in the range 5 to 100 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_134_4 and is of type INTEGER.

Parameter 135: Dif Fahrenheit

Regulator termperature hysteresis, Fahrenheit mode; in 1/10 °F (step 10)

Values in the range 10 to 180 may be set.

The manufacturer defined default value is 20.

This parameter has the configuration ID config_135_4 and is of type INTEGER.

Parameter 136: Frost Celsius

Frost limit in Celcius mode; in 1/10 °C (step 10)

Values in the range 50 to 100 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_136_0 and is of type INTEGER.

Parameter 137: Frost Fahrenheit

Frost limit in Fahrenheit mode; 1/10 °F (step 20)

Values in the range 410 to 510 may be set.

The manufacturer defined default value is 410.

This parameter has the configuration ID config_137_4 and is of type INTEGER.

Parameter 183: Drying Time

Drying time; in minutes (step 5), 0 for off

The following option values may be configured -:

Value Description
0 Off

The manufacturer defined default value is 30.

This parameter has the configuration ID config_183_4 and is of type INTEGER.

Parameter 185: Celcius Floor Limit

Floor limit temperature in Celcius mode; in 1/10 °C (step 50)

Values in the range 50 to 600 may be set.

The manufacturer defined default value is 270.

This parameter has the configuration ID config_185_4 and is of type INTEGER.

Parameter 186: Fahrenheit Floor Limit

Floor limit temperature in Fahrenheit mode; in 1/10 °F (step 10)

Values in the range 410 to 1400 may be set.

The manufacturer defined default value is 810.

This parameter has the configuration ID config_186_4 and is of type INTEGER.

Parameter 187: LCD Display Switch

LCD display switch

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Off
1 On

The manufacturer defined default value is 1 (On).

This parameter has the configuration ID config_187_4 and is of type INTEGER.

Parameter 188: Automatically Get Network Time

Automatically get network time

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Off
1 On

The manufacturer defined default value is 0 (Off).

This parameter has the configuration ID config_188_4 and is of type INTEGER.

Parameter 199: Week Program Time

Four byte fields, see manual This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_199_4 and is of type INTEGER.

Parameter 200: Week Program Celsius

Four byte fields, see manual This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_200_4 and is of type INTEGER.

Parameter 201: Week Program Fahrenheit

Four byte fields, see manual This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_201_4 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 4512757 supports 1 association group.

Group 1:

Report Available commands:

**DEVICE_RESET_LOCALLY_NOTIFICATION
SENSOR_MULTILEVEL_REPORT
BINARY_SWITCH_REPORT
NOTIFICATION_REPORT
CONFIGURATION_REPORT
THERMOSTAT_MODE_REPORT
THERMOSTAT_SETPOINT_REPORT
PROTECTION_REPORT
METER_REPORT
COMMAND_CLASS_INDICATOR
**

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V10
COMMAND_CLASS_METER_V3
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_TRANSPORT_SERVICE_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V2
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_INDICATOR_V3
COMMAND_CLASS_TIME_V1
COMMAND_CLASS_TIME_PARAMETERS_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_SECURITY_2_V1