4512746 Z-Wave Switch 16A

This describes the Z-Wave device * 4512746*, manufactured by Namron with the thing type UID of namron_4512746_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

 4512746 product image

The 4512746 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

https://www.elektroimportoren.no/docs/lib/4512746-Brukerveiledning-5.pdf

Inclusion Information

  1. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion).
  2. Power on the in-wall switch and set it into inclusion mode. There are two methods to set the in-wall switch into inclusion mode:
    1. Triple press the action button on the switch, LED indicator will flash rapidly, it will set the switch into inclusion mode for 30 seconds, if there is no reply from the gateway, the device will quit inclusion mode after 30 seconds.
    2. When the value of parameter 5 is configured as 1, triple press the external switch rapidly within 1.5 seconds, LED indicator will flash rapidly, it will set the switch into inclusion mode for 30 seconds, if there is no reply from the gateway, the device will quit inclusion mode after 30 seconds.

The LED indicator will stay solid on for 3 seconds if the device is added to the network successfully. The indicator will turn off if inclusion fails.

Exclusion Information

There are two exclusion methods:

Method 1: Exclusion from the primary controller/gateway as follows:

  1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion).
  2. Power on the in-wall switch and set it into exclusion mode. There are two methods to set the in-wall switch into exclusion mode:
    1. Triple press the action button on the switch, LED indicator will flash rapidly, it will set the switch into exclusion mode for 30 seconds, if there is no reply from the gateway, the device will quit exclusion mode after 30 seconds.
    2. When the value of parameter 5 is configured as 1, triple press the external switch rapidly within 1.5 seconds, LED indicator will flash rapidly, it will set the switch into exclusion mode for 30 seconds, if there is no reply from the gateway, the device will quit exclusion mode after 30 seconds.

General Usage Information

Channels

The following table summarises the channels available for the 4512746 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Alarm (power) alarm_power alarm_power Energy Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the 4512746. Detailed information on each parameter can be found in the sections below.

Param Name Description
2 Saving load state before power failure Saving load state before power failure
3 Enable/disable to send the basic report Enable/disable to send the basic report to the Lifeline when the load state changed
4 Enable/disable over current or over load protection Enable/disable over current or over load protection, report alarm when the load is over 16A if enabled
5 External switch type External switch type
7 Added to and removed from a network through external switch Added to and removed from a network through external switch (when enables this function, triple press the external switch to be added to or removed from a network)
10 Power change absolute threshold report Power change absolute threshold report, report when the power change value is over the threshold, unit is W
11 Current change absolute threshold Current change absolute threshold, unit is 0.1A
12 Voltage change absolute threshold Voltage change absolute threshold, unit is 1V
13 Time cycle to report the values of energy consumption Time cycle to report the values of energy consumption, voltage, current and load power actively

Parameter 2: Saving load state before power failure

Saving load state before power failure 0 shutoff load
1 turn on load
2 save load state before power failure The following option values may be configured -:

Value Description
0 shutoff load
1 turn on load
2 save load state before power failure

The manufacturer defined default value is 2 (save load state before power failure).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Enable/disable to send the basic report

Enable/disable to send the basic report to the Lifeline when the load state changed 0 Disable to send Basic report
1 Enable to send Basic report The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 1 (Enable).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Enable/disable over current or over load protection

Enable/disable over current or over load protection, report alarm when the load is over 16A if enabled 0: disable
1: enable The following option values may be configured -:

Value Description
0 disable
1 enable

The manufacturer defined default value is 1 (enable).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: External switch type

External switch type 0: push button switch
1: normal on/off switch The following option values may be configured -:

Value Description
0 push
1 normal

The manufacturer defined default value is 0 (push).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 7: Added to and removed from a network through external switch

Added to and removed from a network through external switch (when enables this function, triple press the external switch to be added to or removed from a network) 0 - disable
1 - enable

Note: if this function is enabled, when triple press the switch rapidly, the device will be set to inclusion or exclusion mode, then device status will not be reported (basic report) during this process The following option values may be configured -:

Value Description
0 disable
1 enable

The manufacturer defined default value is 1 (enable).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 10: Power change absolute threshold report

Power change absolute threshold report, report when the power change value is over the threshold, unit is W 0: disable absolute threshold report function

1- 255: value of the power change absolute threshold, if power change value is over the threshold value, report the power change value using METER_REPORT Values in the range 0 to 255 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Current change absolute threshold

Current change absolute threshold, unit is 0.1A 0: disable absolute threshold function

1- 255: value of the current change absolute threshold, if current change value is over the threshold value, report the current change value using METER_REPORT Values in the range 0 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Voltage change absolute threshold

Voltage change absolute threshold, unit is 1V 0: disable absolute threshold function

1- 255: value of the voltage change absolute threshold, if voltage change value is over the threshold value, report the voltage change value using METER_REPORT Values in the range 0 to 255 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Time cycle to report the values of energy consumption

Time cycle to report the values of energy consumption, voltage, current and load power actively 60-2678400 (31 days), value of the time cycle, unit is S.

Default is 1800(30 mins) Values in the range 60 to 2678400 may be set.

The manufacturer defined default value is 1800.

This parameter has the configuration ID config_13_4 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 4512746 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

  1. When press and hold down “Reset” button for 10S to reset the device, send "Device Reset Locally Notification" to associated devices of this group to report factory reset information.

  2. When over load detected, send "NOTIFICATION_REPORT" to associated devices of this group.

  3. Report energy meter actively.

  4. Send basic report automatically

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_TRANSPORT_SERVICE_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_INDICATOR_V3
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_SECURITY_2_V1

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.