--- layout: documentation title: 4512746 - ZWave --- {% include base.html %} # 4512746 Z-Wave Switch 16A This describes the Z-Wave device * 4512746*, manufactured by *Namron* with the thing type UID of ```namron_4512746_00_000```. The device is in the category of *Wall Switch*, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch. ![ 4512746 product image](https://opensmarthouse.org/zwavedatabase/1451/image/) The 4512746 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview https://www.elektroimportoren.no/docs/lib/4512746-Brukerveiledning-5.pdf ### Inclusion Information 1. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion). 2. Power on the in-wall switch and set it into inclusion mode. There are two methods to set the in-wall switch into inclusion mode: 1. Triple press the action button on the switch, LED indicator will flash rapidly, it will set the switch into inclusion mode for 30 seconds, if there is no reply from the gateway, the device will quit inclusion mode after 30 seconds. 2. When the value of parameter 5 is configured as 1, triple press the external switch rapidly within 1.5 seconds, LED indicator will flash rapidly, it will set the switch into inclusion mode for 30 seconds, if there is no reply from the gateway, the device will quit inclusion mode after 30 seconds. The LED indicator will stay solid on for 3 seconds if the device is added to the network successfully. The indicator will turn off if inclusion fails. ### Exclusion Information There are two exclusion methods: Method 1: Exclusion from the primary controller/gateway as follows: 1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion). 2. Power on the in-wall switch and set it into exclusion mode. There are two methods to set the in-wall switch into exclusion mode: 1. Triple press the action button on the switch, LED indicator will flash rapidly, it will set the switch into exclusion mode for 30 seconds, if there is no reply from the gateway, the device will quit exclusion mode after 30 seconds. 2. When the value of parameter 5 is configured as 1, triple press the external switch rapidly within 1.5 seconds, LED indicator will flash rapidly, it will set the switch into exclusion mode for 30 seconds, if there is no reply from the gateway, the device will quit exclusion mode after 30 seconds. ### General Usage Information ## Channels The following table summarises the channels available for the 4512746 -: | Channel Name | Channel ID | Channel Type | Category | Item Type | |--------------|------------|--------------|----------|-----------| | Switch | switch_binary | switch_binary | Switch | Switch | | Scene Number | scene_number | scene_number | | Number | | Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number | | Electric meter (watts) | meter_watts | meter_watts | Energy | Number | | Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number | | Electric meter (amps) | meter_current | meter_current | Energy | Number | | Alarm (power) | alarm_power | alarm_power | Energy | Switch | ### Switch Switch the power on and off. The ```switch_binary``` channel is of type ```switch_binary``` and supports the ```Switch``` item and is in the ```Switch``` category. ### Scene Number Triggers when a scene button is pressed. The ```scene_number``` channel is of type ```scene_number``` and supports the ```Number``` item. ### Electric meter (kWh) Indicates the energy consumption (kWh). The ```meter_kwh``` channel is of type ```meter_kwh``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (watts) Indicates the instantaneous power consumption. The ```meter_watts``` channel is of type ```meter_watts``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (volts) Indicates the instantaneous voltage. The ```meter_voltage``` channel is of type ```meter_voltage``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Electric meter (amps) Indicates the instantaneous current consumption. The ```meter_current``` channel is of type ```meter_current``` and supports the ```Number``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. ### Alarm (power) Indicates if a power alarm is triggered. The ```alarm_power``` channel is of type ```alarm_power``` and supports the ```Switch``` item and is in the ```Energy``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ## Device Configuration The following table provides a summary of the 9 configuration parameters available in the 4512746. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 2 | Saving load state before power failure | Saving load state before power failure | | 3 | Enable/disable to send the basic report | Enable/disable to send the basic report to the Lifeline when the load state changed | | 4 | Enable/disable over current or over load protection | Enable/disable over current or over load protection, report alarm when the load is over 16A if enabled | | 5 | External switch type | External switch type | | 7 | Added to and removed from a network through external switch | Added to and removed from a network through external switch (when enables this function, triple press the external switch to be added to or removed from a network) | | 10 | Power change absolute threshold report | Power change absolute threshold report, report when the power change value is over the threshold, unit is W | | 11 | Current change absolute threshold | Current change absolute threshold, unit is 0.1A | | 12 | Voltage change absolute threshold | Voltage change absolute threshold, unit is 1V | | 13 | Time cycle to report the values of energy consumption | Time cycle to report the values of energy consumption, voltage, current and load power actively | ### Parameter 2: Saving load state before power failure Saving load state before power failure 0 - shutoff load 1 - turn on load 2 - save load state before power failure The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | shutoff load | | 1 | turn on load | | 2 | save load state before power failure | The manufacturer defined default value is ```2``` (save load state before power failure). This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: Enable/disable to send the basic report Enable/disable to send the basic report to the Lifeline when the load state changed 0 - Disable to send Basic report 1 - Enable to send Basic report The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Disable | | 1 | Enable | The manufacturer defined default value is ```1``` (Enable). This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Enable/disable over current or over load protection Enable/disable over current or over load protection, report alarm when the load is over 16A if enabled 0: disable 1: enable The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | disable | | 1 | enable | The manufacturer defined default value is ```1``` (enable). This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 5: External switch type External switch type 0: push button switch 1: normal on/off switch The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | push | | 1 | normal | The manufacturer defined default value is ```0``` (push). This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 7: Added to and removed from a network through external switch Added to and removed from a network through external switch (when enables this function, triple press the external switch to be added to or removed from a network) 0 - disable 1 - enable Note: if this function is enabled, when triple press the switch rapidly, the device will be set to inclusion or exclusion mode, then device status will not be reported (basic report) during this process The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | disable | | 1 | enable | The manufacturer defined default value is ```1``` (enable). This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 10: Power change absolute threshold report Power change absolute threshold report, report when the power change value is over the threshold, unit is W 0: disable absolute threshold report function 1- 255: value of the power change absolute threshold, if power change value is over the threshold value, report the power change value using METER_REPORT Values in the range 0 to 255 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_10_1``` and is of type ```INTEGER```. ### Parameter 11: Current change absolute threshold Current change absolute threshold, unit is 0.1A 0: disable absolute threshold function 1- 255: value of the current change absolute threshold, if current change value is over the threshold value, report the current change value using METER_REPORT Values in the range 0 to 255 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_11_1``` and is of type ```INTEGER```. ### Parameter 12: Voltage change absolute threshold Voltage change absolute threshold, unit is 1V 0: disable absolute threshold function 1- 255: value of the voltage change absolute threshold, if voltage change value is over the threshold value, report the voltage change value using METER_REPORT Values in the range 0 to 255 may be set. The manufacturer defined default value is ```2```. This parameter has the configuration ID ```config_12_1``` and is of type ```INTEGER```. ### Parameter 13: Time cycle to report the values of energy consumption Time cycle to report the values of energy consumption, voltage, current and load power actively 60-2678400 (31 days), value of the time cycle, unit is S. Default is 1800(30 mins) Values in the range 60 to 2678400 may be set. The manufacturer defined default value is ```1800```. This parameter has the configuration ID ```config_13_4``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The 4512746 supports 1 association group. ### Group 1: Lifeline The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. 1. When press and hold down “Reset” button for 10S to reset the device, send "Device Reset Locally Notification" to associated devices of this group to report factory reset information. 2. When over load detected, send "NOTIFICATION_REPORT" to associated devices of this group. 3. Report energy meter actively. 4. Send basic report automatically Association group 1 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_BINARY_V1| | | COMMAND_CLASS_SCENE_ACTIVATION_V1| | | COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1| | | COMMAND_CLASS_METER_V3| | | COMMAND_CLASS_TRANSPORT_SERVICE_V1| | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1| | | COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1| | | COMMAND_CLASS_ZWAVEPLUS_INFO_V1| | | COMMAND_CLASS_SUPERVISION_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V8| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_POWERLEVEL_V1| | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1| | | COMMAND_CLASS_ASSOCIATION_V2| | | COMMAND_CLASS_VERSION_V2| | | COMMAND_CLASS_INDICATOR_V3| | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3| | | COMMAND_CLASS_SECURITY_V1| | | COMMAND_CLASS_SECURITY_2_V1| | ### Documentation Links * [device picture](https://opensmarthouse.org/zwavedatabase/1451/reference/4512746-manual.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](https://opensmarthouse.org/zwavedatabase/1451).