7.5 KiB
layout | title |
---|---|
documentation | YKFCON - ZWave |
{% include base.html %}
YKFCON Smart Living Keyfree Smart Lock
This describes the Z-Wave device YKFCON, manufactured by ASSA ABLOY with the thing type UID of yale_ykfcon_00_000
.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The YKFCON supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
Overview
No device information is provided in the database. Consider updating the database to improve the documentation.
Channels
The following table summarises the channels available for the YKFCON -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Door Lock | lock_door | Door | Switch |
Alarm | alarm_general | Door | Switch |
Battery Level | battery-level | Battery | Number |
Door Lock
Lock and unlock the door.
The lock_door
channel supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
Alarm
Indicates if an alarm is triggered.
The alarm_general
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
Device Configuration
The following table provides a summary of the 7 configuration parameters available in the YKFCON. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Audio Volume | Sets the volume level of the beeps and voice prompts |
2 | Auto Re-lock | When enabled, the unit will automatically re-lock |
3 | Re-lock Time | Time after unlocking that the device will lock |
4 | Wrong Code Entry Limit | The number of invalid tries before the lock shutdowns and sends an alarm |
5 | Language | Language used by the voice prompts |
7 | Shutdown Time | Number of times the device is locked out after the invalid retries are exceeded |
8 | Operating Mode | Sets if the unit operates normal, or disables keypad and Z-Wave lock/unlock |
Lock Timeout | Sets the time after which the door will auto lock |
Parameter 1: Audio Volume
Sets the volume level of the beeps and voice prompts 1 = Silent
2 = Low
3 = High The following option values may be configured -:
Value | Description |
---|---|
1 | Silent |
2 | Low |
3 | High |
The manufacturer defined default value is 3
(High).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Auto Re-lock
When enabled, the unit will automatically re-lock 0 = Off
255 = On The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
255 | On |
The manufacturer defined default value is 0
(Off).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: Re-lock Time
Time after unlocking that the device will lock
Values in the range 5 to 255 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: Wrong Code Entry Limit
The number of invalid tries before the lock shutdowns and sends an alarm
Values in the range 1 to 7 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 5: Language
Language used by the voice prompts 1 = English
2 = Spanish
3 = French The following option values may be configured -:
Value | Description |
---|---|
1 | English |
2 | Spanish |
3 | French |
The manufacturer defined default value is 1
(English).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter 7: Shutdown Time
Number of times the device is locked out after the invalid retries are exceeded
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Parameter 8: Operating Mode
Sets if the unit operates normal, or disables keypad and Z-Wave lock/unlock 0 = Normal
1 = Vacation Mode (User Codes Disabled)
2 = Privacy Mode (User Codes and ZWave Codes Disabled The following option values may be configured -:
Value | Description |
---|---|
0 | Normal |
1 | Vacation Mode |
2 | Privacy Mode |
The manufacturer defined default value is 0
(Normal).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Lock Timeout
Sets the time after which the door will auto lock.
This parameter has the configuration ID doorlock_timeout
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The YKFCON supports 1 association group.
Group 1: Alarm Reports
Alarm reports are sent out to all devices in the association group
Association group 1 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1 | |
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V3 | |
COMMAND_CLASS_DOOR_LOCK_V1 | |
COMMAND_CLASS_USER_CODE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_PROTECTION_V2 | |
COMMAND_CLASS_LOCK_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_TIME_V2 | |
COMMAND_CLASS_TIME_PARAMETERS_V1 | |
COMMAND_CLASS_SECURITY_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.