--- layout: documentation title: YKFCON - ZWave --- {% include base.html %} # YKFCON Smart Living Keyfree Smart Lock This describes the Z-Wave device *YKFCON*, manufactured by *ASSA ABLOY* with the thing type UID of ```yale_ykfcon_00_000```. The device is in the category of *Lock*, defining Devices whose primary pupose is locking something. ![YKFCON product image](https://www.cd-jackson.com/zwave_device_uploads/292/292_default.jpg) The YKFCON supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices. ## Overview No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/292) to improve the documentation. ## Channels The following table summarises the channels available for the YKFCON -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Door Lock | lock_door | Door | Switch | | Alarm | alarm_general | Door | Switch | | Battery Level | battery-level | Battery | Number | ### Door Lock Lock and unlock the door. The ```lock_door``` channel supports the ```Switch``` item and is in the ```Door``` category. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | ON | Locked | | OFF | Unlocked | ### Alarm Indicates if an alarm is triggered. The ```alarm_general``` channel supports the ```Switch``` item and is in the ```Door``` category. This is a read only channel so will only be updated following state changes from the device. The following state translation is provided for this channel to the ```Switch``` item type -: | Value | Label | |-------|-----------| | OFF | OK | | ON | Alarm | ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category. ## Device Configuration The following table provides a summary of the 7 configuration parameters available in the YKFCON. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 1 | Audio Volume | Sets the volume level of the beeps and voice prompts | | 2 | Auto Re-lock | When enabled, the unit will automatically re-lock | | 3 | Re-lock Time | Time after unlocking that the device will lock | | 4 | Wrong Code Entry Limit | The number of invalid tries before the lock shutdowns and sends an alarm | | 5 | Language | Language used by the voice prompts | | 7 | Shutdown Time | Number of times the device is locked out after the invalid retries are exceeded | | 8 | Operating Mode | Sets if the unit operates normal, or disables keypad and Z-Wave lock/unlock | | | Lock Timeout | Sets the time after which the door will auto lock | ### Parameter 1: Audio Volume Sets the volume level of the beeps and voice prompts 1 = Silent 2 = Low 3 = High The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | Silent | | 2 | Low | | 3 | High | The manufacturer defined default value is ```3``` (High). This parameter has the configuration ID ```config_1_1``` and is of type ```INTEGER```. ### Parameter 2: Auto Re-lock When enabled, the unit will automatically re-lock 0 = Off 255 = On The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Off | | 255 | On | The manufacturer defined default value is ```0``` (Off). This parameter has the configuration ID ```config_2_1``` and is of type ```INTEGER```. ### Parameter 3: Re-lock Time Time after unlocking that the device will lock Values in the range 5 to 255 may be set. The manufacturer defined default value is ```30```. This parameter has the configuration ID ```config_3_1``` and is of type ```INTEGER```. ### Parameter 4: Wrong Code Entry Limit The number of invalid tries before the lock shutdowns and sends an alarm Values in the range 1 to 7 may be set. The manufacturer defined default value is ```5```. This parameter has the configuration ID ```config_4_1``` and is of type ```INTEGER```. ### Parameter 5: Language Language used by the voice prompts 1 = English 2 = Spanish 3 = French The following option values may be configured -: | Value | Description | |--------|-------------| | 1 | English | | 2 | Spanish | | 3 | French | The manufacturer defined default value is ```1``` (English). This parameter has the configuration ID ```config_5_1``` and is of type ```INTEGER```. ### Parameter 7: Shutdown Time Number of times the device is locked out after the invalid retries are exceeded Values in the range 1 to 255 may be set. The manufacturer defined default value is ```30```. This parameter has the configuration ID ```config_7_1``` and is of type ```INTEGER```. ### Parameter 8: Operating Mode Sets if the unit operates normal, or disables keypad and Z-Wave lock/unlock 0 = Normal 1 = Vacation Mode (User Codes Disabled) 2 = Privacy Mode (User Codes and ZWave Codes Disabled The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Normal | | 1 | Vacation Mode | | 2 | Privacy Mode | The manufacturer defined default value is ```0``` (Normal). This parameter has the configuration ID ```config_8_1``` and is of type ```INTEGER```. ### Lock Timeout Sets the time after which the door will auto lock. This parameter has the configuration ID ```doorlock_timeout``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The YKFCON supports 1 association group. ### Group 1: Alarm Reports Alarm reports are sent out to all devices in the association group Association group 1 supports 5 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_DOOR_LOCK_LOGGING_V1| | | COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V3| | | COMMAND_CLASS_DOOR_LOCK_V1| | | COMMAND_CLASS_USER_CODE_V1| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_ALARM_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_PROTECTION_V2| | | COMMAND_CLASS_LOCK_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_TIME_V2| | | COMMAND_CLASS_TIME_PARAMETERS_V1| | | COMMAND_CLASS_SECURITY_V1| | ### Documentation Links * [Data Sheet](https://www.cd-jackson.com/zwave_device_uploads/292/yale-smart-living-keyfree-connected-data-sheet.pdf) * [User Manual](https://www.cd-jackson.com/zwave_device_uploads/292/yale-smart-living-keyfree-connected-user-manual.pdf) * [Technical Information](https://www.cd-jackson.com/zwave_device_uploads/292/yale-locks-info.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/292).