6.4 KiB
layout | title |
---|---|
documentation | CT100 - ZWave |
{% include base.html %}
CT100 Z-Wave Thermostat
This describes the Z-Wave device CT100, manufactured by Radio Thermostat Company of America (RTC) with the thing type UID of rtc_ct100_00_000
.
The CT100 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
No device information is provided in the database. Consider updating the database to improve the documentation.
Channels
The following table summarises the channels available for the CT100 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature |
Thermostat mode | thermostat_mode | Temperature | Number |
Operating State | thermostat_state | Temperature | Number |
Setpoint (heating) | thermostat_setpoint | Temperature | Number:Temperature |
Setpoint (cooling) | thermostat_setpoint | Temperature | Number:Temperature |
Thermostat fan mode | thermostat_fanmode | ||
Thermostat fan state | thermostat_fanstate | ||
Battery Level | battery-level | Battery | Number |
Time Offset | time_offset | Temperature | Number |
Sensor (temperature) 1 | sensor_temperature1 | Temperature | Number:Temperature |
Relative Humidity | sensor_relhumidity2 | Humidity | Number |
Sensor (temperature)
Indicates the current temperature.
The sensor_temperature
channel supports the Number:Temperature
item and is in the Temperature
category.
Thermostat mode
Sets the thermostat.
The thermostat_mode
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Operating State
Sets the thermostat operating state.
The thermostat_state
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Setpoint (heating)
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
Setpoint (cooling)
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
Thermostat fan mode
Channel type information on this channel is not found.
Thermostat fan state
Channel type information on this channel is not found.
Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
Time Offset
Provides the current time difference for the devices time.
The time_offset
channel supports the Number
item and is in the Temperature
category.
Sensor (temperature) 1
Indicates the current temperature.
The sensor_temperature1
channel supports the Number:Temperature
item and is in the Temperature
category.
Relative Humidity
Indicates the current relative humidity.
The sensor_relhumidity2
channel supports the Number
item and is in the Humidity
category. This is a read only channel so will only be updated following state changes from the device.
Device Configuration
The device has no configuration parameters defined.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The CT100 supports 1 association group.
Group 1: Group 1
Send report about Thermostat Mode, Thermostat Operating State, Fan Mode, Fan State, Setpoint, Sensor Multilevel
Association group 1 supports 2 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V2 | |
COMMAND_CLASS_THERMOSTAT_MODE_V2 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V2 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_INDICATOR_V1 |
Endpoint 1
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V2 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_V1 |
Endpoint 2
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V2 | |
COMMAND_CLASS_ASSOCIATION_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.