--- layout: documentation title: CT100 - ZWave --- {% include base.html %} # CT100 Z-Wave Thermostat This describes the Z-Wave device *CT100*, manufactured by *Radio Thermostat Company of America (RTC)* with the thing type UID of ```rtc_ct100_00_000```. ![CT100 product image](https://www.cd-jackson.com/zwave_device_uploads/96/96_default.jpg) The CT100 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network. ## Overview No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/96) to improve the documentation. ## Channels The following table summarises the channels available for the CT100 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature | | Thermostat mode | thermostat_mode | Temperature | Number | | Operating State | thermostat_state | Temperature | Number | | Setpoint (heating) | thermostat_setpoint | Temperature | Number:Temperature | | Setpoint (cooling) | thermostat_setpoint | Temperature | Number:Temperature | | Thermostat fan mode | thermostat_fanmode | | | | Thermostat fan state | thermostat_fanstate | | | | Battery Level | battery-level | Battery | Number | | Time Offset | time_offset | Temperature | Number | | Sensor (temperature) 1 | sensor_temperature1 | Temperature | Number:Temperature | | Relative Humidity | sensor_relhumidity2 | Humidity | Number | ### Sensor (temperature) Indicates the current temperature. The ```sensor_temperature``` channel supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Thermostat mode Sets the thermostat. The ```thermostat_mode``` channel supports the ```Number``` item and is in the ```Temperature``` category. The following state translation is provided for this channel to the ```Number``` item type -: | Value | Label | |-------|-----------| | 0 | Off | | 1 | Heat | | 2 | Cool | | 3 | Auto | | 4 | Aux Heat | | 5 | Resume | | 6 | Fan Only | | 7 | Furnace | | 8 | Dry Air | | 9 | Moist Air | | 10 | Auto Changeover | | 11 | Heat Economy | | 12 | Cool Economy | | 13 | Away | ### Operating State Sets the thermostat operating state. The ```thermostat_state``` channel supports the ```Number``` item and is in the ```Temperature``` category. The following state translation is provided for this channel to the ```Number``` item type -: | Value | Label | |-------|-----------| | 0 | Idle | | 1 | Heating | | 2 | Cooling | | 3 | Fan Only | | 4 | Pending Heat | | 5 | Pending Cool | | 6 | Vent / Economiser | ### Setpoint (heating) Sets the thermostat setpoint. The ```thermostat_setpoint``` channel supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Setpoint (cooling) Sets the thermostat setpoint. The ```thermostat_setpoint``` channel supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Thermostat fan mode Channel type information on this channel is not found. ### Thermostat fan state Channel type information on this channel is not found. ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category. ### Time Offset Provides the current time difference for the devices time. The ```time_offset``` channel supports the ```Number``` item and is in the ```Temperature``` category. ### Sensor (temperature) 1 Indicates the current temperature. The ```sensor_temperature1``` channel supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Relative Humidity Indicates the current relative humidity. The ```sensor_relhumidity2``` channel supports the ```Number``` item and is in the ```Humidity``` category. This is a read only channel so will only be updated following state changes from the device. ## Device Configuration The device has no configuration parameters defined. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The CT100 supports 1 association group. ### Group 1: Group 1 Send report about Thermostat Mode, Thermostat Operating State, Fan Mode, Fan State, Setpoint, Sensor Multilevel Association group 1 supports 2 nodes. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V2| | | COMMAND_CLASS_THERMOSTAT_MODE_V2| | | COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V2| | | COMMAND_CLASS_THERMOSTAT_SETPOINT_V2| | | COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1| | | COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1| | | COMMAND_CLASS_MULTI_CHANNEL_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_CLOCK_V1| | | COMMAND_CLASS_ASSOCIATION_V1| | | COMMAND_CLASS_VERSION_V1| | | COMMAND_CLASS_INDICATOR_V1| | #### Endpoint 1 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V2| Linked to BASIC| | COMMAND_CLASS_ASSOCIATION_V1| | #### Endpoint 2 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V2| | | COMMAND_CLASS_ASSOCIATION_V1| | ### Documentation Links * [Installation Guide](https://www.cd-jackson.com/zwave_device_uploads/96/CT100-Install-Guide.pdf) * [CT100-SimpleSpecs](https://www.cd-jackson.com/zwave_device_uploads/96/CT100-Specs.pdf) * [CT100 Users guide](https://www.cd-jackson.com/zwave_device_uploads/96/Smart-Thermostat-User-Guide.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/96).