ZXT-120 AC IR Remote
This describes the Z-Wave device ZXT-120, manufactured by Remotec with the thing type UID of remotec_zxt120_00_000
.
The ZXT-120 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
Overview
No device information is provided in the database. Consider updating the database to improve the documentation.
Channels
The following table summarises the channels available for the ZXT-120 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature |
Thermostat mode | thermostat_mode | Temperature | Number |
Setpoint (cooling) | thermostat_setpoint | Temperature | Number:Temperature |
Setpoint (heating) | thermostat_setpoint | Temperature | Number:Temperature |
Thermostat fan mode | thermostat_fanmode | ||
Battery Level | battery-level | Battery | Number |
Sensor (temperature)
Indicates the current temperature.
The sensor_temperature
channel supports the Number:Temperature
item and is in the Temperature
category.
Thermostat mode
Sets the thermostat.
The thermostat_mode
channel supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Setpoint (cooling)
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
Setpoint (heating)
Sets the thermostat setpoint.
The thermostat_setpoint
channel supports the Number:Temperature
item and is in the Temperature
category.
Thermostat fan mode
Channel type information on this channel is not found.
Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
Device Configuration
The following table provides a summary of the 8 configuration parameters available in the ZXT-120. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
25 | Indicate a location for IR code learning and start learning | |
26 | Learning status register (Read Only) | |
27 | IR code number for built-in code library | |
28 | External IR Emitter power level | |
32 | Surround IR control | |
33 | AC function Swing control | |
35 | Learn location status. Bitmask. (Read Only) | |
37 | Sensor temperature compensation | |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 25: Indicate a location for IR code learning and start learning
Values in the range 0 to 22 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_25_1
and is of type INTEGER
.
Parameter 26: Learning status register (Read Only)
Values in the range 0 to 4 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_26_1
and is of type INTEGER
.
This is a read only parameter.
Parameter 27: IR code number for built-in code library
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_27_2
and is of type INTEGER
.
Parameter 28: External IR Emitter power level
The following option values may be configured -:
Value | Description |
---|---|
0 | Normal power mode |
255 | High power mode |
The manufacturer defined default value is 255
(High power mode).
This parameter has the configuration ID config_28_1
and is of type INTEGER
.
Parameter 32: Surround IR control
The following option values may be configured -:
Value | Description |
---|---|
-1 | Enable Surround IR Emitters |
0 | Disable Surround IR Emitters |
The manufacturer defined default value is -1
(Enable Surround IR Emitters).
This parameter has the configuration ID config_32_1
and is of type INTEGER
.
Parameter 33: AC function Swing control
The following option values may be configured -:
Value | Description |
---|---|
0 | Swing Off |
1 | Swing Auto |
The manufacturer defined default value is 1
(Swing Auto).
This parameter has the configuration ID config_33_1
and is of type INTEGER
.
Parameter 35: Learn location status. Bitmask. (Read Only)
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_35_4
and is of type INTEGER
.
This is a read only parameter.
Parameter 37: Sensor temperature compensation
Values in the range -5 to 5 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_37_1
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V1 | |
COMMAND_CLASS_THERMOSTAT_MODE_V2 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_VERSION_V1 |