--- layout: documentation title: ZXT-120 - ZWave --- {% include base.html %} # ZXT-120 AC IR Remote This describes the Z-Wave device *ZXT-120*, manufactured by *Remotec* with the thing type UID of ```remotec_zxt120_00_000```. The ZXT-120 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices. ## Overview No device information is provided in the database. Consider [updating the database](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/202) to improve the documentation. ## Channels The following table summarises the channels available for the ZXT-120 -: | Channel | Channel Id | Category | Item Type | |---------|------------|----------|-----------| | Sensor (temperature) | sensor_temperature | Temperature | Number:Temperature | | Thermostat mode | thermostat_mode | Temperature | Number | | Setpoint (cooling) | thermostat_setpoint | Temperature | Number:Temperature | | Setpoint (heating) | thermostat_setpoint | Temperature | Number:Temperature | | Thermostat fan mode | thermostat_fanmode | | | | Battery Level | battery-level | Battery | Number | ### Sensor (temperature) Indicates the current temperature. The ```sensor_temperature``` channel supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Thermostat mode Sets the thermostat. The ```thermostat_mode``` channel supports the ```Number``` item and is in the ```Temperature``` category. The following state translation is provided for this channel to the ```Number``` item type -: | Value | Label | |-------|-----------| | 0 | Off | | 1 | Heat | | 2 | Cool | | 3 | Auto | | 4 | Aux Heat | | 5 | Resume | | 6 | Fan Only | | 7 | Furnace | | 8 | Dry Air | | 9 | Moist Air | | 10 | Auto Changeover | | 11 | Heat Economy | | 12 | Cool Economy | | 13 | Away | ### Setpoint (cooling) Sets the thermostat setpoint. The ```thermostat_setpoint``` channel supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Setpoint (heating) Sets the thermostat setpoint. The ```thermostat_setpoint``` channel supports the ```Number:Temperature``` item and is in the ```Temperature``` category. ### Thermostat fan mode Channel type information on this channel is not found. ### Battery Level Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading. The ```battery-level``` channel supports the ```Number``` item and is in the ```Battery``` category. ## Device Configuration The following table provides a summary of the 8 configuration parameters available in the ZXT-120. Detailed information on each parameter can be found in the sections below. | Param | Name | Description | |-------|-------|-------------| | 25 | Indicate a location for IR code learning and start learning | | | 26 | Learning status register (Read Only) | | | 27 | IR code number for built-in code library | | | 28 | External IR Emitter power level | | | 32 | Surround IR control | | | 33 | AC function Swing control | | | 35 | Learn location status. Bitmask. (Read Only) | | | 37 | Sensor temperature compensation | | | | Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands | ### Parameter 25: Indicate a location for IR code learning and start learning Values in the range 0 to 22 may be set. The manufacturer defined default value is ```1```. This parameter has the configuration ID ```config_25_1``` and is of type ```INTEGER```. ### Parameter 26: Learning status register (Read Only) Values in the range 0 to 4 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_26_1``` and is of type ```INTEGER```. This is a read only parameter. ### Parameter 27: IR code number for built-in code library Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_27_2``` and is of type ```INTEGER```. ### Parameter 28: External IR Emitter power level The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Normal power mode | | 255 | High power mode | The manufacturer defined default value is ```255``` (High power mode). This parameter has the configuration ID ```config_28_1``` and is of type ```INTEGER```. ### Parameter 32: Surround IR control The following option values may be configured -: | Value | Description | |--------|-------------| | -1 | Enable Surround IR Emitters | | 0 | Disable Surround IR Emitters | The manufacturer defined default value is ```-1``` (Enable Surround IR Emitters). This parameter has the configuration ID ```config_32_1``` and is of type ```INTEGER```. ### Parameter 33: AC function Swing control The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Swing Off | | 1 | Swing Auto | The manufacturer defined default value is ```1``` (Swing Auto). This parameter has the configuration ID ```config_33_1``` and is of type ```INTEGER```. ### Parameter 35: Learn location status. Bitmask. (Read Only) Values in the range 0 to 65535 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_35_4``` and is of type ```INTEGER```. This is a read only parameter. ### Parameter 37: Sensor temperature compensation Values in the range -5 to 5 may be set. The manufacturer defined default value is ```0```. This parameter has the configuration ID ```config_37_1``` and is of type ```INTEGER```. ### Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands. The following option values may be configured -: | Value | Description | |--------|-------------| | 0 | Exclude from All On and All Off groups | | 1 | Include in All On group | | 2 | Include in All Off group | | 255 | Include in All On and All Off groups | This parameter has the configuration ID ```switchall_mode``` and is of type ```INTEGER```. ## Association Groups Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic. The device does not support associations. ## Technical Information ### Endpoints #### Endpoint 0 | Command Class | Comment | |---------------|---------| | COMMAND_CLASS_NO_OPERATION_V1| | | COMMAND_CLASS_BASIC_V1| | | COMMAND_CLASS_SWITCH_ALL_V1| | | COMMAND_CLASS_SENSOR_MULTILEVEL_V1| | | COMMAND_CLASS_THERMOSTAT_MODE_V2| | | COMMAND_CLASS_THERMOSTAT_SETPOINT_V2| | | COMMAND_CLASS_THERMOSTAT_FAN_MODE_V2| | | COMMAND_CLASS_CONFIGURATION_V1| | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1| | | COMMAND_CLASS_BATTERY_V1| | | COMMAND_CLASS_VERSION_V1| | ### Documentation Links * [User Manual](https://www.cd-jackson.com/zwave_device_uploads/202/ZXT-120-User-Manual-V1-4-20130604.pdf) --- Did you spot an error in the above definition or want to improve the content? You can [contribute to the database here](http://www.cd-jackson.com/index.php/zwave/zwave-device-database/zwave-device-list/devicesummary/202).