4.7 KiB
layout | title |
---|---|
documentation | LSM-15 - ZWave |
{% include base.html %}
LSM-15 Wall Mounted Switch
This describes the Z-Wave device LSM-15, manufactured by Evolve with the thing type UID of evolve_lsm15_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The LSM-15 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
No device information is provided in the database. Consider updating the database to improve the documentation.
Channels
The following table summarises the channels available for the LSM-15 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | Number |
Switch
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Dimmer
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
Scene Number
Triggers when a scene button is pressed.
The scene_number
channel supports the Number
item.
Device Configuration
The following table provides a summary of the 2 configuration parameters available in the LSM-15. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | Night Light | By default, the LED will turn OFF when the lead attached is turned ON. |
4 | Invert Switch | To change the top of the switch to OFF and the bottom of the switch ON. |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 3: Night Light
By default, the LED will turn OFF when the lead attached is turned ON.
The following option values may be configured -:
Value | Description |
---|---|
0 | On when load is on |
1 | Off when load is on |
The manufacturer defined default value is 1
(Off when load is on).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: Invert Switch
To change the top of the switch to OFF and the bottom of the switch ON.
The following option values may be configured -:
Value | Description |
---|---|
0 | Top-ON, Bottom-OFF |
1 | Bottom--ON, Top-OFF |
The manufacturer defined default value is 0
(Top-ON, Bottom-OFF).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_VERSION_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.