id: ecotouch
|
|
label: EcoTouch
|
|
title: EcoTouch - Bindings
|
|
type: binding
|
|
description: "The openHAB EcoTouch binding allows interaction with a heat pump."
|
|
source: https://github.com/openhab/openhab1-addons/blob/master/bundles/binding/org.openhab.binding.ecotouch/README.md
|
|
since: 1x
|
|
logo: images/addons/ecotouch.png
|
|
install: auto
|
|
---
|
|
|
|
<!-- Attention authors: Do not edit directly. Please add your changes to the appropriate source repository -->
|
|
|
|
{% include base.html %}
|
|
|
|
# EcoTouch Binding
|
|
|
|
The openHAB EcoTouch binding allows interaction with a heat pump.
|
|
|
|
|
|
## Prerequisites
|
|
|
|
Make sure the display unit of the heat pump is connected to the network and
|
|
that the network settings are configured. By default, the heat pump uses DHCP.
|
|
|
|
|
|
## Binding Configuration
|
|
|
|
The binding can be configured in the file `services/ecotouch.cfg`.
|
|
|
|
| Property | Default | Required | Description |
|
|
|----------|------------|:--------:|-------------|
|
|
| ip | | Yes | ip or DNS name of the heat pump |
|
|
| username | waterkotte | No | username for login |
|
|
| password | waterkotte | No | password for login |
|
|
|
|
NOTE: Since Waterkotte Display software version 1.6.xx, the username/password
|
|
default value is `waterkotte`. Prior to that, the username default was `admin`
|
|
and the password default was `wtkadmin`.
|
|
|
|
|
|
## Item Configuration
|
|
|
|
The binding configuration format is simple and looks like this:
|
|
|
|
ecotouch="<eventType>"
|
|
|
|
where `<eventType>` is one of the following values:
|
|
|
|
| Description | `<eventType>` | ItemClass | Write | Notes |
|
|
| ----------- | ------------- | --------- | ----- | ----- |
|
|
| Außentemperatur | temperature_outside | number | |
|
|
| Außentemperatur gemittelt über 1h | temperature_outside_1h | number | |
|
|
| Außentemperatur gemittelt über 24h | temperature_outside_24h | number | |
|
|
| Quelleneintrittstemperatur | temperature_source_in | number | | Ai1 Geo only |
|
|
| Quellenaustrittstemperatur | temperature_source_out | number | | Ai1 Geo only |
|
|
| Umgebungstemperatur | temperature_surrounding | number | | Ai1 Air only |
|
|
| Verdampfungstemperatur | temperature_evaporation | number | |
|
|
| Sauggastemperatur | temperature_suction | number | | Ai1 Geo only |
|
|
| Sauggas | temperature_suction_air | number | | Ai1 Air only |
|
|
| Ölsumpf | temperature_sump | number | | Ai1 Air only |
|
|
| Verdampfungsdruck | pressure_evaporation | number | |
|
|
| Temperatur Rücklauf Soll | temperature_return_set | number | |
|
|
| Temperatur Rücklauf | temperature_return | number | |
|
|
| Temperatur Vorlauf | temperature_flow | number | |
|
|
| Kondensationstemperatur | temperature_condensation | number | |
|
|
| Kondensationsdruck | pressure_condensation | number | |
|
|
| Speichertemperatur | temperature_storage | number | |
|
|
| Raumtemperatur | temperature_room | number | |
|
|
| Raumtemperatur gemittelt über 1h | temperature_room_1h | number | |
|
|
| Warmwassertemperatur | temperature_water | number | |
|
|
| Pooltemperatur | temperature_pool | number | |
|
|
| Solarkollektortemperatur | temperature_solar | number | |
|
|
| Solarkreis Vorlauf | temperature_solar_flow | number | |
|
|
| Ventilöffnung elektrisches Expansionsventil % | position_expansion_valve | number | |
|
|
| elektrische Leistung Verdichter | power_compressor | number | |
|
|
| abgegebene thermische Heizleistung der Wärmepumpe | power_heating | number | |
|
|
| abgegebene thermische KälteLeistung der Wärmepumpe | power_cooling | number | |
|
|
| COP Heizleistung | cop_heating | number | |
|
|
| COP Kälteleistung | cop_cooling | number | |
|
|
| Aktuelle Heizkreistemperatur | temperature_heating_return | number | |
|
|
| Geforderte Temperatur im Heizbetrieb | temperature_heating_set | number | |
|
|
| Sollwertvorgabe Heizkreistemperatur | temperature_heating_set2 | number | yes |
|
|
| Aktuelle Kühlkreistemperatur | temperature_cooling_return | number | |
|
|
| Geforderte Temperatur im Kühlbetrieb | temperature_cooling_set | number | |
|
|
| Sollwertvorgabe Kühlbetrieb | temperature_cooling_set2 | number | yes |
|
|
| Sollwert Warmwassertemperatur | temperature_water_set | number | |
|
|
| Sollwertvorgabe Warmwassertemperatur | temperature_water_set2 | number | yes |
|
|
| Sollwert Poolwassertemperatur | temperature_pool_set | number | |
|
|
| Sollwertvorgabe Poolwassertemperatur | temperature_pool_set2 | number | yes |
|
|
| geforderte Verdichterleistung | compressor_power | number | |
|
|
| % Heizungsumwälzpumpe | percent_heat_circ_pump | number | |
|
|
| % Quellenpumpe | percent_source_pump | number | |
|
|
| % Leistung Verdichter | percent_compressor | number | |
|
|
| Heizkurve - Norm-Aussen-Temp (Auslegungstemp)| nviNormAussen | number | yes |
|
|
| Heizkurve - Temp Heizkreis bei Auslegungstemp | nviHeizkreisNorm | number | yes |
|
|
| Heizkurve - Temp Heizgrenze | nviTHeizgrenze | number | yes |
|
|
| Heizkurve - Temp Heizkreis Heizgrenze | nviTHeizgrenzeSoll | number | yes |
|
|
| Heizkurve - max. VL-Temp | maxVLTemp | number | yes |
|
|
| Kühlen Einschalt-Aussentemp | coolEnableTemp | number | yes |
|
|
| geforderte Kühltemperatur | nviSollKuehlen | number | |
|
|
| Firmware-Version Regler | version_controller | number | |
|
|
| Build-Nr. Regler | version_controller_build | number | |
|
|
| Bios-Version Regler | version_bios | number | |
|
|
| Datum: Tag | date_day | number | |
|
|
| Datum: Monat | date_month | number | |
|
|
| Datum: Jahr | date_year | number | |
|
|
| Uhrzeit: Stunde | time_hour | number | |
|
|
| Uhrzeit: Minute | time_minute | number | |
|
|
| Betriebsstunden Verdichter 1 | operating_hours_compressor1 | number | |
|
|
| Betriebsstunden Verdichter 2 | operating_hours_compressor2 | number | |
|
|
| Betriebsstunden Heizungsumwälzpumpe | operating_hours_circulation_pump | number | |
|
|
| Betriebsstunden Quellenpumpe | operating_hours_source_pump | number | |
|
|
| Betriebsstunden Solarkreis | operating_hours_solar | number | |
|
|
| Handabschaltung Heizbetrieb | enable_heating | switch | yes |
|
|
| Handabschaltung Kühlbetrieb | enable_cooling | switch | yes |
|
|
| Handabschaltung Warmwasserbetrieb | enable_warmwater | switch | yes |
|
|
| Handabschaltung Pool_Heizbetrieb | enable_pool | switch | yes |
|
|
| Status der Wärmepumpenkomponenten | state | number | | State as a number, see below for possible mapping. |
|
|
| Status Quellenpumpe | state_sourcepump | switch | |
|
|
| Status Heizungsumwälzpumpe | state_heatingpump | switch | |
|
|
| Status Freigabe Regelung EDV / Magnetventil | state_evd | switch | |
|
|
| Status Verdichter 1 | state_compressor1 | switch | |
|
|
| Status Verdichter 2 | state_compressor2 | switch | |
|
|
| Status externer Wärmeerzeuger | state_extheater | switch | |
|
|
| Status Alarmausgang | state_alarm | switch | |
|
|
| Status Motorventil Kühlbetrieb | state_cooling | switch | |
|
|
| Status Motorventil Warmwasser | state_water | switch | |
|
|
| Status Motorventil Pool | state_pool | switch | |
|
|
| Status Solarbetrieb | state_solar | switch | |
|
|
| Status 4-Wege-Ventil | state_cooling4way | switch | |
|
|
| Temperaturanpassung für die Heizung -2,0 / +2,0 | adapt_heating | number | yes | -2 bis +2 (0,5)---> 0 bis 8
|
|
| Handschaltung Heizungspumpe | manual_heatingpump | | yes | (H-0-A) H= manuell ein (Handschaltung), 0= aus, A= Automatik
|
|
| Handschaltung Quellenpumpe | manual_sourcepump | | yes | (H-0-A)
|
|
| Handschaltung Solarpumpe 1 | manual_solarpump1 | | yes | (H-0-A)
|
|
| Handschaltung Solarpumpe 2 | manual_solarpump2 | | yes | (H-0-A)
|
|
| Handschaltung Speicherladepumpe | manual_tankpump | | yes | (H-0-A)
|
|
| Handschaltung Brauchwasserventil | manual_valve | | yes | (H-0-A)
|
|
| Handschaltung Poolventil | manual_poolvalve | | yes | (H-0-A)
|
|
| Handschaltung Kühlventil | manual_coolvalve | | yes | (H-0-A)
|
|
| Handschaltung Vierwegeventil | manual_4wayvalve | | yes | (H-0-A)
|
|
| Handschaltung Multiausgang Ext. | manual_multiext | | yes | (H-0-A)
|
|
|
|
### Mappings
|
|
|
|
Heatpump event type "state" can be mapped to strings. Different heatpump models seem to have slightly different state values.
|
|
Mappings for the Ai1 Geo have been copied from [here](http://www.haustechnikdialog.de/Forum/t/173357/Waterkotte-via-Ethernet-OpenHAB-und-Android-App?page=6).
|
|
|
|
| State | Ai1 Geo | Ai1 Air |
|
|
| ----- | ----- | ----- |
|
|
| 0 | aus | aus |
|
|
| 1 | nur Solepumpe 1 | |
|
|
| 2 | nur Heizkreispumpe 2 | Standby |
|
|
| 3 | unbekannt | |
|
|
| 7 | unbekannt | |
|
|
| 10 | | Heizbetrieb |
|
|
| 15 | Heizbetrieb | |
|
|
| 131 | Naturkühlung | |
|
|
| 256 | Vorlauf Warmwasser | Vorlauf Warmwasser |
|
|
| 258 | Nachlauf Warmwasser | Nachlauf Warmwasser |
|
|
| 259 | unbekannt 259 vor WW Bereitung | |
|
|
| 263 | unbekannt 263 vor WW Bereitung | |
|
|
| 266 | | Warmwasserbereitung |
|
|
| 271 | Warmwasserbereitung | |
|
|
|
|
|
|
## Examples
|
|
|
|
### Items examples
|
|
|
|
/* Waterkotte EcoTouch heat pump DEMO */
|
|
Group Heatpump
|
|
Group Heatpump_outside
|
|
Group Heatpump_source
|
|
Group Heatpump_control
|
|
Group Heatpump_water
|
|
Group Heatpump_heating
|
|
Group Heatpump_power
|
|
Group Heatpump_state
|
|
Number Chart_Period "Chart Period"
|
|
Number HeatPump_Temperature_3 "Wärmepumpe Außentemperatur [%.1f °C]" <temperature> (Heatpump,Heatpump_outside) { ecotouch="temperature_outside" }
|
|
Number HeatPump_Temperature_4 "Wärmepumpe Außentemperatur 1h [%.1f °C]" <temperature> (Heatpump,Heatpump_outside) { ecotouch="temperature_outside_1h" }
|
|
Number HeatPump_Temperature_5 "Wärmepumpe Außentemperatur 24h [%.1f °C]" <temperature> (Heatpump,Heatpump_outside) { ecotouch="temperature_outside_24h" }
|
|
Number HeatPump_Temperature_6 "Wärmepumpe Quelleneintrittstemperatur [%.1f °C]" <temperature> (Heatpump,Heatpump_source) { ecotouch="temperature_source_in" }
|
|
Number HeatPump_Temperature_7 "Wärmepumpe Quellenaustrittstemperatur [%.1f °C]" <temperature> (Heatpump,Heatpump_source) { ecotouch="temperature_source_out" }
|
|
Number HeatPump_Temperature_8 "Wärmepumpe Vorlauf [%.1f °C]" <temperature> (Heatpump,Heatpump_control) { ecotouch="temperature_flow" }
|
|
Number HeatPump_Temperature_9 "Wärmepumpe Rücklauf [%.1f °C]" <temperature> (Heatpump,Heatpump_control) { ecotouch="temperature_return" }
|
|
Number HeatPump_Temperature_10 "Wärmepumpe Rücklauf Soll [%.1f °C]" <temperature> (Heatpump,Heatpump_control) { ecotouch="temperature_return_set" }
|
|
Number HeatPump_Temperature_11 "Wärmepumpe Warmwasser Ist [%.1f °C]" <temperature> (Heatpump,Heatpump_water) { ecotouch="temperature_water" }
|
|
Number HeatPump_Temperature_12 "Wärmepumpe Warmwasser Soll [%.1f °C]" <temperature> (Heatpump,Heatpump_water) { ecotouch="temperature_water_set" }
|
|
Number HeatPump_Temperature_13 "Wärmepumpe Warmwasser Soll2 [%.1f °C]" <temperature> (Heatpump,Heatpump_water) { ecotouch="temperature_water_set2" }
|
|
Number HeatPump_Temperature_14 "Wärmepumpe Heizung Ist [%.1f °C]" <temperature> (Heatpump,Heatpump_heating) { ecotouch="temperature_heating_return" }
|
|
Number HeatPump_Temperature_15 "Wärmepumpe Heizung Soll [%.1f °C]" <temperature> (Heatpump,Heatpump_heating) { ecotouch="temperature_heating_set" }
|
|
Number HeatPump_Temperature_16 "Wärmepumpe Heizung Soll2 [%.1f °C]" <temperature> (Heatpump,Heatpump_heating) { ecotouch="temperature_heating_set2" }
|
|
Number HeatPump_power_1 "Wärmepumpe elektrische Leistung [%.1f kW]" <energy> (Heatpump,Heatpump_power) { ecotouch="power_compressor" }
|
|
Number HeatPump_power_2 "Wärmepumpe thermische Leistung [%.1f kW]" <energy> (Heatpump,Heatpump_power) { ecotouch="power_heating" }
|
|
Number HeatPump_state "Wärmepumpe Status [%i]" <settings> (Heatpump) { ecotouch="state" }
|
|
Number HeatPump_state_sourcepump "Wärmepumpe Status Quellenpumpe [%i]" <settings> (Heatpump,Heatpump_state) { ecotouch="state_sourcepump" }
|
|
Number HeatPump_state_heatingpump "Wärmepumpe Status Heizungsumwälzpumpe [%i]" <settings> (Heatpump,Heatpump_state) { ecotouch="state_heatingpump" }
|
|
Number HeatPump_state_compressor1 "Wärmepumpe Status Kompressor [%i]" <settings> (Heatpump,Heatpump_state) { ecotouch="state_compressor1" }
|
|
Number HeatPump_state_water "Wärmepumpe Status Motorventil Warmwasser[%i]" <settings> (Heatpump,Heatpump_state) { ecotouch="state_water" }
|
|
|
|
### Sitemap examples
|
|
|
|
Frame label="Waterkotte" {
|
|
Text item=HeatPump_Temperature_3 {
|
|
Frame {
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
|
|
Chart item=Heatpump_outside period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
|
|
Chart item=Heatpump_outside period=D refresh=60000 visibility=[Chart_Period==1]
|
|
Chart item=Heatpump_outside period=W refresh=60000 visibility=[Chart_Period==2]
|
|
}
|
|
}
|
|
Text item=HeatPump_Temperature_6 {
|
|
Frame {
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
|
|
Chart item=Heatpump_source period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
|
|
Chart item=Heatpump_source period=D refresh=60000 visibility=[Chart_Period==1]
|
|
Chart item=Heatpump_source period=W refresh=60000 visibility=[Chart_Period==2]
|
|
}
|
|
}
|
|
Text item=HeatPump_Temperature_7 {
|
|
Frame {
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
|
|
Chart item=Heatpump_source period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
|
|
Chart item=Heatpump_source period=D refresh=60000 visibility=[Chart_Period==1]
|
|
Chart item=Heatpump_source period=W refresh=60000 visibility=[Chart_Period==2]
|
|
}
|
|
}
|
|
Text item=HeatPump_Temperature_8 {
|
|
Frame {
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
|
|
Chart item=Heatpump_control period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
|
|
Chart item=Heatpump_control period=D refresh=60000 visibility=[Chart_Period==1]
|
|
Chart item=Heatpump_control period=W refresh=60000 visibility=[Chart_Period==2]
|
|
}
|
|
}
|
|
Text item=HeatPump_Temperature_9 {
|
|
Frame {
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
|
|
Chart item=Heatpump_control period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
|
|
Chart item=Heatpump_control period=D refresh=60000 visibility=[Chart_Period==1]
|
|
Chart item=Heatpump_control period=W refresh=60000 visibility=[Chart_Period==2]
|
|
}
|
|
}
|
|
Text item=HeatPump_Temperature_10 {
|
|
Frame {
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
|
|
Chart item=Heatpump_control period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
|
|
Chart item=Heatpump_control period=D refresh=60000 visibility=[Chart_Period==1]
|
|
Chart item=Heatpump_control period=W refresh=60000 visibility=[Chart_Period==2]
|
|
}
|
|
}
|
|
Text item=HeatPump_Temperature_11 {
|
|
Frame {
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
|
|
Chart item=Heatpump_water period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
|
|
Chart item=Heatpump_water period=D refresh=60000 visibility=[Chart_Period==1]
|
|
Chart item=Heatpump_water period=W refresh=60000 visibility=[Chart_Period==2]
|
|
}
|
|
}
|
|
Text item=HeatPump_Temperature_12 {
|
|
Frame {
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
|
|
Chart item=Heatpump_water period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
|
|
Chart item=Heatpump_water period=D refresh=60000 visibility=[Chart_Period==1]
|
|
Chart item=Heatpump_water period=W refresh=60000 visibility=[Chart_Period==2]
|
|
}
|
|
}
|
|
Text item=HeatPump_Temperature_13 {
|
|
Frame {
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
|
|
Chart item=Heatpump_water period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
|
|
Chart item=Heatpump_water period=D refresh=60000 visibility=[Chart_Period==1]
|
|
Chart item=Heatpump_water period=W refresh=60000 visibility=[Chart_Period==2]
|
|
}
|
|
}
|
|
Text item=HeatPump_Temperature_14 {
|
|
Frame {
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
|
|
Chart item=Heatpump_heating period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
|
|
Chart item=Heatpump_heating period=D refresh=60000 visibility=[Chart_Period==1]
|
|
Chart item=Heatpump_heating period=W refresh=60000 visibility=[Chart_Period==2]
|
|
}
|
|
}
|
|
Text item=HeatPump_Temperature_15 {
|
|
Frame {
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
|
|
Chart item=Heatpump_heating period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
|
|
Chart item=Heatpump_heating period=D refresh=60000 visibility=[Chart_Period==1]
|
|
Chart item=Heatpump_heating period=W refresh=60000 visibility=[Chart_Period==2]
|
|
}
|
|
}
|
|
Text item=HeatPump_Temperature_16 {
|
|
Frame {
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
|
|
Chart item=Heatpump_heating period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
|
|
Chart item=Heatpump_heating period=D refresh=60000 visibility=[Chart_Period==1]
|
|
Chart item=Heatpump_heating period=W refresh=60000 visibility=[Chart_Period==2]
|
|
}
|
|
}
|
|
Text item=HeatPump_power_1 {
|
|
Frame {
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
|
|
Chart item=Heatpump_power period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
|
|
Chart item=Heatpump_power period=D refresh=60000 visibility=[Chart_Period==1]
|
|
Chart item=Heatpump_power period=W refresh=60000 visibility=[Chart_Period==2]
|
|
}
|
|
}
|
|
Text item=HeatPump_power_2 {
|
|
Frame {
|
|
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
|
|
Chart item=Heatpump_power period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
|
|
Chart item=Heatpump_power period=D refresh=60000 visibility=[Chart_Period==1]
|
|
Chart item=Heatpump_power period=W refresh=60000 visibility=[Chart_Period==2]
|
|
}
|
|
}
|
|
}
|
|
|
|
|
|
### Gallery
|
|
|
|
The following charts are created via the rrd4j chart and heatpump bundle.
|
|
|
|

|
|
|
|

|