4.1 KiB
layout | title |
---|---|
documentation | ZM1602 - ZWave |
{% include base.html %}
ZM1602 AC/DC Siren
This describes the Z-Wave device ZM1602, manufactured by Vision Security with the thing type UID of vision_zm1602_15_000
.
This version of the device is limited to firmware versions above 15.0
The ZM1602 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
No device information is provided in the database. Consider updating the database to improve the documentation.
Channels
The following table summarises the channels available for the ZM1602 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Alarm (burglar) | alarm_burglar | Door | Switch |
Switch
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
Alarm (burglar)
Indicates if the burglar alarm is triggered.
The alarm_burglar
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Device Configuration
The following table provides a summary of the 2 configuration parameters available in the ZM1602. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Siren Strobe Mode | Defines the reaction of the siren |
2 | Alarm auto stop | Defines the auto time out of the alarm indication |
Parameter 1: Siren Strobe Mode
Defines the reaction of the siren
The following option values may be configured -:
Value | Description |
---|---|
0 | Strobe and Siren |
1 | Siren |
2 | Strobe |
The manufacturer defined default value is 0
(Strobe and Siren).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Alarm auto stop
Defines the auto time out of the alarm indication
The following option values may be configured -:
Value | Description |
---|---|
0 | 30 seconds |
1 | 60 seconds |
2 | 120 seconds |
3 | Continuous |
The manufacturer defined default value is 0
(30 seconds).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V4 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_SECURITY_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.