12 KiB
layout | title |
---|---|
documentation | Z-CM-V01 - ZWave |
{% include base.html %}
Z-CM-V01 SmartWings Motorized Window Treatments
This describes the Z-Wave device Z-CM-V01, manufactured by Zemismart with the thing type UID of zemismart_smartwingszcmv1_00_000
.
The device is in the category of Blinds, defining Roller shutters, window blinds, etc..
The Z-CM-V01 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
Overview
Motor control device that powers smart window treatments from brands such as SmartWings and Zemismart
Inclusion Information
Pairing Method 1:
- 1. Remove the back cover of the remote.
- 2. Briefly press the P button until the motor jogs once.
- 3. Press the UP button until the motor jogs again.
- 4. Press the P button once more until the motor jogs once.
- 5. A red LED light will illuminate, indicating the motor is in inclusion mode
Pairing Method 2:
- 1. Press and hold the P1 button on the motor head for 6 seconds until the motor jogs twice.
- 2. A red LED light will illuminate, indicating the motor is in inclusion mode
Exclusion Information
-
- Remove the back cover of the remote.
-
- Briefly press the P button until the motor jogs once.
-
- Press the DOWN button until the motor jogs again.
-
- Press the P button once more until the motor jogs once.
General Usage Information
Channels
The following table summarises the channels available for the Z-CM-V01 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Blinds Control | blinds_control | blinds_control | Blinds | Rollershutter |
Alarm (power) | alarm_power | alarm_power | Energy | Switch |
Battery Level | battery-level | system.battery_level | Battery | Number |
Blinds Control
Provides start / stop control of blinds.
The blinds_control
channel is of type blinds_control
and supports the Rollershutter
item and is in the Blinds
category.
Alarm (power)
Indicates if a power alarm is triggered.
The alarm_power
channel is of type alarm_power
and supports the Switch
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
Device Configuration
The following table provides a summary of the 10 configuration parameters available in the Z-CM-V01. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Set to start holding hands | This parameter can be used to set the motor open hand start function |
2 | Set motor direction | This parameter can be used to set the motor rotation direction. |
3 | Manually set open borders | Manually set / cancel open borders |
4 | Manually set close borders | Manually set / cancel close borders |
5 | Set motor status | Set motor status |
6 | Calibration the limit position | Calibration the limit position |
7 | Delete the limit position | Delete the limit position |
8 | Low battery level alarm threshold | Configure low battery report threshold, sends low battery report via battery report when battery level drops under setting |
9 | Battery auto report interval time | Interval time set in seconds. Battery Report will be sent when timeout. |
10 | Battery change report threshold | Battery level range = 1% to 50% |
Parameter 1: Set to start holding hands
This parameter can be used to set the motor open hand start function This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | close |
1 | Open |
The manufacturer defined default value is 1
(open).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Set motor direction
This parameter can be used to set the motor rotation direction. This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 1 to 3 -:
Value | Description |
---|---|
1 | forward |
2 | opposite |
3 | reversing |
The manufacturer defined default value is 1
(forward).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: Manually set open borders
Manually set / cancel open borders This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | cancel |
1 | set |
The manufacturer defined default value is 0
(cancel).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: Manually set close borders
Manually set / cancel close borders This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | cancel |
1 | set |
The manufacturer defined default value is 0
(cancel).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 5: Set motor status
Set motor status This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 1 to 3 -:
Value | Description |
---|---|
1 | Open |
2 | close |
3 | stop |
The manufacturer defined default value is 3
(stop).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter 6: Calibration the limit position
Calibration the limit position This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 1 to 3 -:
Value | Description |
---|---|
1 | up |
2 | down |
3 | third |
The manufacturer defined default value is 1
(up).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Parameter 7: Delete the limit position
Delete the limit position This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 0 to 3 -:
Value | Description |
---|---|
0 | all |
1 | up |
2 | down |
3 | third |
The manufacturer defined default value is 0
(all).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Parameter 8: Low battery level alarm threshold
Configure low battery report threshold, sends low battery report via battery report when battery level drops under setting This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 50 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Parameter 9: Battery auto report interval time
Interval time set in seconds. Battery Report will be sent when timeout. This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 2678400 may be set.
The manufacturer defined default value is 3600
.
This parameter has the configuration ID config_9_4
and is of type INTEGER
.
Parameter 10: Battery change report threshold
Battery level range = 1% to 50% This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 50 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The Z-CM-V01 supports 4 association groups.
Group 1: Group 1
Switch Multilevel Report / Device Reset Locally / Indicator Report
- Switch Multilevel Report.
Changings of curtain caused by user action or receiving of Multilevel Set or Basic Set or Window Covering Set will trigger.
- Device Reset Locally.
Config Button is press and hold for 10 seconds.
- Indicator Report
Receiving Indicator Set will trigger this CC.
Association group 1 supports 5 nodes.
Group 2: Group 2
Basic set Send Basic Set to Group 2 when receiving Basic Set
Association group 2 supports 5 nodes.
Group 3: Group 3
Switch Multilevel Set Send Switch Multilevel Set to Group 3 when receiving Switch Multilevel Set
Association group 3 supports 5 nodes.
Group 4: Group 4
Switch Multilevel Start Level Change / Stop Level Change Send Switch Multilevel Start Level Change / Stop Level Change to Group 4 when receiving Switch Multilevel Start Level Change / Stop Level Change
Association group 4 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_APPLICATION_STATUS_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | Linked to BASIC |
COMMAND_CLASS_TRANSPORT_SERVICE_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_WINDOW_COVERING_V1 | |
COMMAND_CLASS_SUPERVISION_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V8 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_INDICATOR_V3 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | |
COMMAND_CLASS_SECURITY_2_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.