MYOT2 OpenTherm Interfaces for boiler
This describes the Z-Wave device MYOT2, manufactured by SmartDHOME with the thing type UID of smartdhome_myot2_00_000
.
The device is in the category of Controller, defining Central control interface.
The MYOT2 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
Interface/actuator for OpenTherm boilers that allows you to monitor the performance of the OpenTherm boilers on which it is installed.
Inclusion Information
Include the MyOT device by pressing the function button for 8 seconds.
Exclusion Information
Include the MyOT device by pressing the function button for 8 seconds.
General Usage Information
Control the boiler using the OpenTherm protocol
Channels
The following table summarises the channels available for the MYOT2 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Boiler On/Off | switch_binary | switch_binary | Switch | Switch |
Heating circuit pressure | sensor_barpressure | sensor_barpressure | Pressure | Number |
Return water temperature | water_temperature | sensor_temperature | Temperature | Number:Temperature |
Boiler heating modulation | sensor_heatingmodulation | sensor_heatingmodulation | ||
DHW Flow | sensor_waterflow | sensor_waterflow | ||
Boiler water temperature | boiler_watertemp | sensor_temperature | Temperature | Number:Temperature |
DHW water temperature | dhw_temperature | sensor_temperature | Temperature | Number:Temperature |
Exhaust fumes temperature | exhaust_temperature | sensor_temperature | Temperature | Number:Temperature |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Setpoint DHW | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Boiler On/Off
Switch the boiler on/off
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Heating circuit pressure
Water pressure of the boiler
Indicates the barometric pressure.
The sensor_barpressure
channel is of type sensor_barpressure
and supports the Number
item and is in the Pressure
category. This is a read only channel so will only be updated following state changes from the device.
Return water temperature
Return water temperature
Indicates the current temperature.
The water_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Boiler heating modulation
Boiler heating modulation in percent
Channel type information on this channel is not found.
DHW Flow
DHW (Heating water) flow
Channel type information on this channel is not found.
Boiler water temperature
Boiler (heating) water temperature
Indicates the current temperature.
The boiler_watertemp
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
DHW water temperature
DHW (hot) water temperature
Indicates the current temperature.
The dhw_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Exhaust fumes temperature
Indicates the current temperature.
The exhaust_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Setpoint (heating)
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Setpoint DHW
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Device Configuration
The following table provides a summary of the 9 configuration parameters available in the MYOT2. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Max setpoint of the boiler | Max setpoint of the boiler |
2 | Min setpoint of the boiler | Min setpoint of the boiler |
3 | Setpoint max DHW | Setpoint max DHW (hot water) |
4 | Setpoint min DHW | Setpoint min DHW |
10 | Error Flag | Error number of the boiler if any, default 0 |
11 | Error code | Error code, if error occurs |
30 | Summer mode | Summer mode (0: no 1: yes) |
31 | Enabling DHW | Enabling DHW (hot water, 0: no 1: yes) |
95 | Report rate | Report rate (in min) |
Parameter 1: Max setpoint of the boiler
Max setpoint of the boiler
Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_1_0
and is of type INTEGER
.
Parameter 2: Min setpoint of the boiler
Min setpoint of the boiler
Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_0
and is of type INTEGER
.
Parameter 3: Setpoint max DHW
Setpoint max DHW (hot water)
Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_3_0
and is of type INTEGER
.
Parameter 4: Setpoint min DHW
Setpoint min DHW
Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_4_0
and is of type INTEGER
.
Parameter 10: Error Flag
Error number of the boiler if any, default 0
Values in the range 0 to 999999999 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Parameter 11: Error code
Error code, if error occurs
Values in the range 0 to 999999 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_11_5
and is of type INTEGER
.
Parameter 30: Summer mode
Summer mode (0: no 1: yes)
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
Parameter 31: Enabling DHW
Enabling DHW (hot water, 0: no 1: yes)
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_31_1
and is of type INTEGER
.
Parameter 95: Report rate
Report rate (in min)
Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_95_0
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The MYOT2 supports 1 association group.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 1 node.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V10 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_TRANSPORT_SERVICE_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | |
COMMAND_CLASS_SECURITY_V1 | |
COMMAND_CLASS_SECURITY_2_V1 |