Wave 2PM Z-Wave™ smart switch, 2 channels 16 A total current (18 A peak), with power metering

This describes the Z-Wave device Wave 2PM, manufactured by Shelly with the thing type UID of shelly_wave2pm_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

Wave 2PM product image

The Wave 2PM supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Remotely control two independent electrical appliances (e.g. lights) and monitor their power consumption separately and in total.

  • 2 channels (2x 10 A, 16 A total)
  • Power metering on each channel and in total
  • Extremely low power consumption: 0.3 W.
  • Z-Wave frequency band: 868.4 MHz (CEPT countries)
  • Latest technology: Z-Wave 800 Series
  • Automatic set-up with SmartStart
  • Security 2 Authenticated for the highest level of security
  • Supports over-the-air firmware updates
  • Simple installation in most standard electrical boxes and switches
  • Works with Z-Wave certified gateways and over 4,000 Z-Wave devices

*A gateway (smart hub) is not included. A gateway (smart hub) is required for the configuration of the device.

Inclusion Information

SmartStart adding (inclusion)

SmartStart enabled products can be added into a Z-Wave™ network by scanning the Z-Wave™ QR Code present on the Device with a gateway providing SmartStart inclusion. No further action is required, and the SmartStart device will be added automatically within 10 minutes of being switched on in the network vicinity.

  1. With the gateway application scan the QR code on the Device label and add the Security 2 (S2) Device Specific Key (DSK) to the provisioning list in the gateway.
  2. Connect the Device to a power supply.
  3. Check if the blue LED is blinking slowly. If so, the Device is not added to a Z-Wave™ network.
  4. Adding will be initiated automatically within a few seconds after connecting the Device to a power supply, and the Device will be added to a Z-Wave™ network automatically.
  5. The blue LED will be blinking faster during the adding process.
  6. The green LED will be blinking in slowly if the Device is successfully added to a Z-Wave™ network.

Adding (inclusion) with the S button

  1. Connect the Device to a power supply.
  2. Check if the blue LED is blinking slowly. If so, the Device is not added to a Z-Wave™ network.
  3. Enable add/remove mode on the gateway.
  4. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue.
  5. Quickly release and then press and hold (> 2s) the S button on the Device until the blue LED starts blinking slowly. Releasing the S button will start the Learn mode.
  6. The blue LED will be blinking faster during the adding process.
  7. The green LED will be blinking slowly if the Device is successfully added to a Z-Wave™ network.

Note! In Setting mode, the Device has a timeout of 10s before entering again into Normal mode.

Adding (inclusion) with a switch/push-button

  1. Connect the Device to a power supply.
  2. Check if the blue LED is blinking slowly. If so, the Device is not added to a Z-Wave™ network.
  3. Enable add/remove mode on the gateway.
  4. Toggle the switch/push-button connected to any of the SW terminals (SW, SW1, SW2, etc.) 3 times within 3 seconds (this procedure puts the Device in Learn mode*). The Device must receive on/off signal 3 times, which means pressing the momentary switch 3 times, or toggling the switch on and off 3 times.
  5. The blue LED will be blinking faster during the adding process.
  6. The green LED will be blinking slowly if the Device is successfully added to a Z-Wave™ network.

*Learn mode - a state that allows the Device to receive network information from the gateway.

Exclusion Information

Removing the Device from a Z-Wave™ network (exclusion)

Note! The Device will be removed from your Z-wave™ network, but any custom configuration parameters will not be erased.

Note! All Device outputs (O, O1, O2, etc. - depending on the Device type) will turn the load 1s on/1s off /1s on/1s off if the Device is successfully added to/removed from a Z-Wave™ network.

Removing (exclusion) with the S button

    1. Connect the Device to a power supply.
    1. Check if the green LED will be blinking slowly. If so, the Device is added to a Z-Wave™ network.
    1. Enable add/remove mode on the gateway.
    1. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue.
    1. Quickly release and then press and hold (> 2s) the S button on the Device until the blue LED starts blinking slowly. Releasing the S button will start the LEARN MODE.
    1. The blue LED will be blinking faster during the removing process.
    1. The blue LED will be blinking slower if the Device is successfully removed from a Z-Wave™ network.

Note! In Setting mode, the Device has a timeout of 10s before entering again into Normal mode.

Removing (exclusion) with a switch/push-button

    1. Connect the Device to a power supply.
    1. Check if the green LED will be blinking slowly. If so, the Device is added to a Z-Wave™ network.
    1. Enable add/remove mode on the gateway.
    1. Toggle the switch/push-button connected to any of the SW terminals (SW, SW1, SW2,…) 3 times within 3 seconds (this procedure puts the Device in LEARN MODE). The Device must receive on/off signal 3 times, which means pressing the momentary switch 3 times, or toggling the switch on and off 3 times.
    1. The blue LED will be blinking faster during the removing process.
    1. The blue LED will be blinking slower if the Device is successfully removed from a Z-Wave™ network.

General Usage Information

Factory reset

Factory reset general

After Factory reset, all custom parameters and stored values (kWh, associations, routing, etc.) will return to their default state. HOME ID and NODE ID assigned to the Device will be deleted. Use this reset procedure only when the gateway is missing or otherwise inoperable.

Factory reset with the S button

Note! Factory reset with the S button is possible anytime.

    1. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue.
    1. Press the S button multiple times until the LED turns solid red.
    1. Press and hold (> 2s) S button on the Device until the red LED starts blinking faster. Releasing the S button will start the factory reset.
    1. During factory reset, the LED will turn solid green for about 1s, then the blue and red LED will start blinking faster for approx. 2s.
    1. The blue LED will be blinking slower if the Factory reset is successful.

Factory reset with a switch/push-button

Note! Factory reset with a switch/push-button is only possible within the first minute after the Device is connected to a power supply.

    1. Connect the Device to a power supply.
    1. Toggle the switch/push-button connected to any of the SW terminals (SW, SW1, SW2,…) 5 times within 3 seconds. The Device must receive on/off signal 5 times, which means pressing the push-button 5 times, or toggling the switch on and off 5 times.
    1. During factory reset, the LED will turn solid green for about 1s, then the blue and red LED will start blinking faster for approx. 2s.
    1. The blue LED will be blinking slower if the Factory reset is successful.

Factory reset remotely with parameter with the gateway

    1. Factory reset can be done remotely by settings in Parameter No. 120

Channels

The following table summarises the channels available for the Wave 2PM -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Alarm (heat) alarm_heat alarm_heat Fire Switch
Alarm (power) alarm_power alarm_power Energy Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Alarm (heat) 1 alarm_heat1 alarm_heat Fire Switch
Alarm (power) 1 alarm_power1 alarm_power Energy Switch
Switch 2 switch_binary2 switch_binary Switch Switch
Electric meter (kWh) 2 meter_kwh2 meter_kwh Energy Number
Electric meter (watts) 2 meter_watts2 meter_watts Energy Number
Alarm (heat) 2 alarm_heat2 alarm_heat Fire Switch
Alarm (power) 2 alarm_power2 alarm_power Energy Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm (heat)

Indicates if a heat alarm is triggered.

The alarm_heat channel is of type alarm_heat and supports the Switch item and is in the Fire category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Switch 1

Switch the power on and off.

The switch_binary1 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (kWh) 1

Indicates the energy consumption (kWh).

The meter_kwh1 channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 1

Indicates the instantaneous power consumption.

The meter_watts1 channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm (heat) 1

Indicates if a heat alarm is triggered.

The alarm_heat1 channel is of type alarm_heat and supports the Switch item and is in the Fire category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (power) 1

Indicates if a power alarm is triggered.

The alarm_power1 channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Switch 2

Switch the power on and off.

The switch_binary2 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (kWh) 2

Indicates the energy consumption (kWh).

The meter_kwh2 channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 2

Indicates the instantaneous power consumption.

The meter_watts2 channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm (heat) 2

Indicates if a heat alarm is triggered.

The alarm_heat2 channel is of type alarm_heat and supports the Switch item and is in the Fire category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (power) 2

Indicates if a power alarm is triggered.

The alarm_power2 channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 26 configuration parameters available in the Wave 2PM. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 SW (SW1) Switch type This parameter defines how the Device should treat the switch (which type) connected to the SW (SW1) terminal.
2 SW2 Switch type This parameter defines how the Device should treat the switch (which type) connected to the SW2 terminal.
6 Inputs SW1 & SW2 Swap This parameter allows to swap the operation of switches connected to inputs SW1 and SW2 without changing the wiring.
16 Outputs O1 & O2 swap This parameter allows to swap the operation of outputs O1 and O2 without changing the wiring (in case of an invalid motor connection) to ensure proper operation.
17 Restore the O (O1) state after a power failure This parameter determines if the on/off status is saved and restored for the load connected to O (O1) after a power failure.
18 Restore the O2 state after a power failure This parameter determines if the on/off status is saved and restored for the load connected to O2 after a power failure.
19 O (O1) Auto OFF with timer If the load O (O1) is ON, you can schedule it to turn OFF automatically after the period of time defined in this parameter. The timer resets to zero each time the Device receives an ON command, either remotely (from the gateway or associated device) or lo
20 O (O1) Auto ON with timer If the load O (O1) is ON, you can schedule it to turn OFF automatically after the period of time defined in this parameter. The timer resets to zero each time the Device receives an ON command, either remotely (from the gateway or associated device) or lo
21 O2 Auto OFF with timer If the load O2 is ON, you can schedule it to turn OFF automatically after the period of time defined in this parameter. The timer resets to zero each time the device receives an ON command, either remotely (from the gateway or associated device) or locall
22 O2 Auto ON with timer If the load O2 is OFF, you can schedule it to turn ON automatically after the period of time defined in this parameter. The timer resets to zero each time the device receives an OFF command, either remotely (from the gateway or associated device) or local
23 O (O1) contact type - NO/NC The set value determines the relay contact type for output O (O1). The relay contact type can be normally open (NO) or normally closed (NC).
24 O2 contact type - NO/NC The set value determines the type of Relay contact type for O2 output. The Relay contact type can be normally open (NO) or normally closed (NC).
25 Set timer units to s or ms for O (O1) Set the timer units to seconds or milliseconds. Choose if you want to set the timer in seconds or milliseconds in Parameters No. 19, 20.
26 Set timer units to s or ms for O2 Set the timer units to seconds or milliseconds. Choose if you want to set the timer in seconds or milliseconds in Parameters No. 21, 22.
36 O (O1) Power report on change - percentage This parameter determines the minimum change in consumed power that will result in sending a new report to the gateway.
37 O2 Power report on change - percentage This parameter determines the minimum change in consumed power that will result in sending a new report to the gateway.
39 Minimum time between reports (O) O1 This parameter determines the minimum time that must elapse before a new power report on O (O1) is sent to the gateway.
40 Minimum time between reports O2 This parameter determines the minimum time that must elapse before a new power report on O2 is sent to the gateway.
91 Water Alarm This parameter determines which alarm frames the Device should respond to and how. The parameters consist of 4 bytes, the three most significant bytes are set according to the official Z-Wave protocol specification.
92 Smoke Alarm This parameter determines which alarm frames the Device should respond to and how. The parameters consist of 4 bytes, the three most significant bytes are set according to the official Z-Wave protocol specification.
93 CO Alarm This parameter determines which alarm frames the Device should respond to and how. The parameters consist of 4 bytes, the three most significant bytes are set according to the official Z-Wave protocol specification.
94 Heat Alarm This parameter determines which alarm frames the Device should respond to and how. The parameters consist of 4 bytes, the three most significant bytes are set according to the official Z-Wave protocol specification.
120 Factory Reset Reset to factory default settings and removed from the Z-Wave network. The parameter is Advanced and may be hidden under the Advanced tag.
201 Serial Number 1 This parameter contains a part of devices serial number. The parameter is Read-Only and cannot be changed. The parameter is Advanced and may be hidden under the Advanced tag.
202 Serial Number 2 This parameter contains a part of devices serial number. The parameter is Read-Only and cannot be changed. The parameter is Advanced and may be hidden under the Advanced tag.
203 Serial Number 3 This parameter contains a part of devices serial number. The parameter is Read-Only and cannot be changed. The parameter is Advanced and may be hidden under the Advanced tag.

Parameter 1: SW (SW1) Switch type

This parameter defines how the Device should treat the switch (which type) connected to the SW (SW1) terminal.

The following option values may be configured, in addition to values in the range 0 to 2 -:

Value Description
0 seconds or milliseconds see Parameter no. 25. Set timer units to s o
1 toggle switch (contact closed - ON / contact opened - OFF)
2 toggle switch (Device changes status when switch changes status)

The manufacturer defined default value is 2 (toggle switch (Device changes status when switch changes status)).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: SW2 Switch type

This parameter defines how the Device should treat the switch (which type) connected to the SW2 terminal.

The following option values may be configured, in addition to values in the range 0 to 2 -:

Value Description
0 momentary switch (push button)
1 toggle switch (contact closed - ON / contact opened - OFF)
2 toggle switch (Device changes status when switch changes status)

The manufacturer defined default value is 2 (toggle switch (Device changes status when switch changes status)).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 6: Inputs SW1 & SW2 Swap

This parameter allows to swap the operation of switches connected to inputs SW1 and SW2 without changing the wiring.

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 default (SW1 - O1, SW2 - O2)
1 swapped (SW1 - O2, SW2 - O1)

The manufacturer defined default value is 0 (default (SW1 - O1, SW2 - O2)).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 16: Outputs O1 & O2 swap

This parameter allows to swap the operation of outputs O1 and O2 without changing the wiring (in case of an invalid motor connection) to ensure proper operation.

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 default
1 reversed

The manufacturer defined default value is 0 (default).

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 17: Restore the O (O1) state after a power failure

This parameter determines if the on/off status is saved and restored for the load connected to O (O1) after a power failure.

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Device saves last on/off status and restores it after a power failure
1 Device does not save on/off status, it remains off

The manufacturer defined default value is 0 (Device saves last on/off status and restores it after a power failure).

This parameter has the configuration ID config_17_1 and is of type INTEGER.

Parameter 18: Restore the O2 state after a power failure

This parameter determines if the on/off status is saved and restored for the load connected to O2 after a power failure.

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Device saves last on/off status and restores it after a power failure
1 Device does not save on/off status, it remains off

The manufacturer defined default value is 0 (Device saves last on/off status and restores it after a power failure).

This parameter has the configuration ID config_18_1 and is of type INTEGER.

Parameter 19: O (O1) Auto OFF with timer

If the load O (O1) is ON, you can schedule it to turn OFF automatically after the period of time defined in this parameter. The timer resets to zero each time the Device receives an ON command, either remotely (from the gateway or associated device) or lo seconds or milliseconds see Parameter no. 25. Set timer units to s or ms for O (O1) resolution 100ms Values in the range 0 to 32535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_19_2 and is of type INTEGER.

Parameter 20: O (O1) Auto ON with timer

If the load O (O1) is ON, you can schedule it to turn OFF automatically after the period of time defined in this parameter. The timer resets to zero each time the Device receives an ON command, either remotely (from the gateway or associated device) or lo seconds (or milliseconds see Parameter No. 25. Set timer units to s or ms for O (O1) resolution 100ms Values in the range 0 to 32535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_20_2 and is of type INTEGER.

Parameter 21: O2 Auto OFF with timer

If the load O2 is ON, you can schedule it to turn OFF automatically after the period of time defined in this parameter. The timer resets to zero each time the device receives an ON command, either remotely (from the gateway or associated device) or locall seconds (or milliseconds see Parameter no. 26. Set timer units to s or ms for O2 resolution 100ms Values in the range 0 to 32535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_21_2 and is of type INTEGER.

Parameter 22: O2 Auto ON with timer

If the load O2 is OFF, you can schedule it to turn ON automatically after the period of time defined in this parameter. The timer resets to zero each time the device receives an OFF command, either remotely (from the gateway or associated device) or local seconds (or milliseconds see Parameter no. 26. Set timer units to s or ms for O2 resolution 100ms Values in the range 0 to 32535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_22_2 and is of type INTEGER.

Parameter 23: O (O1) contact type - NO/NC

The set value determines the relay contact type for output O (O1). The relay contact type can be normally open (NO) or normally closed (NC).

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 NO
1 NC

The manufacturer defined default value is 0 (NO).

This parameter has the configuration ID config_23_1 and is of type INTEGER.

Parameter 24: O2 contact type - NO/NC

The set value determines the type of Relay contact type for O2 output. The Relay contact type can be normally open (NO) or normally closed (NC).

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 NO
1 NC

The manufacturer defined default value is 0 (NO).

This parameter has the configuration ID config_24_1 and is of type INTEGER.

Parameter 25: Set timer units to s or ms for O (O1)

Set the timer units to seconds or milliseconds. Choose if you want to set the timer in seconds or milliseconds in Parameters No. 19, 20.

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 timer set in seconds
1 timer set in milliseconds

The manufacturer defined default value is 0 (timer set in seconds).

This parameter has the configuration ID config_25_1 and is of type INTEGER.

Parameter 26: Set timer units to s or ms for O2

Set the timer units to seconds or milliseconds. Choose if you want to set the timer in seconds or milliseconds in Parameters No. 21, 22.

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 timer set in seconds
1 timer set in milliseconds

The manufacturer defined default value is 0 (timer set in seconds).

This parameter has the configuration ID config_26_1 and is of type INTEGER.

Parameter 36: O (O1) Power report on change - percentage

This parameter determines the minimum change in consumed power that will result in sending a new report to the gateway. NOTE! When the Device reports the power consumption (W), it will also automatically report the voltage (V) and current (A).

NOTE! Regardless of the power consumption change in percentage, the report will not be sent more frequently than defined by Parameter No. 39. Values in the range 0 to 100 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_36_1 and is of type INTEGER.

Parameter 37: O2 Power report on change - percentage

This parameter determines the minimum change in consumed power that will result in sending a new report to the gateway. NOTE! When the Device reports the power consumption (W), it will also automatically report the voltage (V) and current (A).

NOTE! Regardless of the power consumption change in percentage, the report will not be sent more frequently than defined by Parameter No. 40. Values in the range 0 to 100 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_37_1 and is of type INTEGER.

Parameter 39: Minimum time between reports (O) O1

This parameter determines the minimum time that must elapse before a new power report on O (O1) is sent to the gateway. NOTE! This Parameter is in relation to Parameter No. 36.

NOTE! Setting the value to less than 30s can cause the Z-Wave network congestion state (slow Device response and decreased network stability). Values in the range 0 to 120 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_39_1 and is of type INTEGER.

Parameter 40: Minimum time between reports O2

This parameter determines the minimum time that must elapse before a new power report on O2 is sent to the gateway. NOTE! This Parameter is in relation to Parameter No. 37

NOTE! Setting the value to less than 30s can cause the Z-Wave network congestion state (slow Device response and decreased network stability). Values in the range 0 to 120 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_40_1 and is of type INTEGER.

Parameter 91: Water Alarm

This parameter determines which alarm frames the Device should respond to and how. The parameters consist of 4 bytes, the three most significant bytes are set according to the official Z-Wave protocol specification.

The following option values may be configured, in addition to values in the range 0 to 2 -:

Value Description
0 no action
1 open relay / Open blinds (Up position)
2 close relay / Close blinds (Down position)

The manufacturer defined default value is 0 (no action).

This parameter has the configuration ID config_91_4 and is of type INTEGER.

Parameter 92: Smoke Alarm

This parameter determines which alarm frames the Device should respond to and how. The parameters consist of 4 bytes, the three most significant bytes are set according to the official Z-Wave protocol specification.

The following option values may be configured, in addition to values in the range 0 to 2 -:

Value Description
0 no action
1 open relay / Open blinds (Up position)
2 close relay / Close blinds (Down position)

The manufacturer defined default value is 0 (no action).

This parameter has the configuration ID config_92_4 and is of type INTEGER.

Parameter 93: CO Alarm

This parameter determines which alarm frames the Device should respond to and how. The parameters consist of 4 bytes, the three most significant bytes are set according to the official Z-Wave protocol specification.

The following option values may be configured, in addition to values in the range 0 to 2 -:

Value Description
0 no action
1 open relay / Open blinds (Up position)
2 close relay / Close blinds (Down position)

The manufacturer defined default value is 0 (no action).

This parameter has the configuration ID config_93_4 and is of type INTEGER.

Parameter 94: Heat Alarm

This parameter determines which alarm frames the Device should respond to and how. The parameters consist of 4 bytes, the three most significant bytes are set according to the official Z-Wave protocol specification.

The following option values may be configured, in addition to values in the range 0 to 2 -:

Value Description
0 no action
1 open relay / Open blinds (Up position)
2 close relay / Close blinds (Down position)

The manufacturer defined default value is 0 (no action).

This parameter has the configuration ID config_94_4 and is of type INTEGER.

Parameter 120: Factory Reset

Reset to factory default settings and removed from the Z-Wave network. The parameter is Advanced and may be hidden under the Advanced tag.

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Dont do Factory reset
1 Do the Factory reset

The manufacturer defined default value is 0 (Dont do Factory reset).

This parameter has the configuration ID config_120_1 and is of type INTEGER.

Parameter 201: Serial Number 1

This parameter contains a part of devices serial number. The parameter is Read-Only and cannot be changed. The parameter is Advanced and may be hidden under the Advanced tag.

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_201_4 and is of type INTEGER. This is a read only parameter.

Parameter 202: Serial Number 2

This parameter contains a part of devices serial number. The parameter is Read-Only and cannot be changed. The parameter is Advanced and may be hidden under the Advanced tag.

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_202_4 and is of type INTEGER. This is a read only parameter.

Parameter 203: Serial Number 3

This parameter contains a part of devices serial number. The parameter is Read-Only and cannot be changed. The parameter is Advanced and may be hidden under the Advanced tag.

Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_203_4 and is of type INTEGER. This is a read only parameter.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The Wave 2PM supports 5 association groups.

Group 1: Association Group 1 - Lifeline

“Lifeline Group” reports the status of the Device status and allows to assign only one device (gateway by default); only 1 node is allowed Association Group 1 - Lifeline

  1. INDICATOR_REPORT : LED status

  2. DEVICE_RESET_LOCALLY_NOTIFICATION : triggered upon request

  3. SWITCH_BINARY_REPORT : status change report for all outputs O (O, O1, O2, …) - common

  4. NOTIFICATION_REPORT : triggered on Overheat

  5. NOTIFICATION_REPORT : triggered on Over-current detected sum of all outputs O (O1+O2+…)

  6. NOTIFICATION_REPORT : triggered on Over-voltage detected

  7. NOTIFICATION_REPORT : triggered on AC mains disconnected

  8. METER_REPORT : triggered by the load power consumption of all connected loads to all outputs O (O1+O2+…) (according to the settings of Parameters from No. 36 to 43)

Association group 1 supports 2 nodes.

Group 2: Association Group 2

It is assigned to switch connected to the SW (SW1) terminal (uses Basic command class). Triggered by SW (SW1). The device sends according to the state of SW (SW1) (switch or push-button) the command BASIC_SET ON or BASIC_SET OFF to the associated device. This command is reflected to the output of associated device. Supports the following command classes:

BASIC_SET : set On / Off state at the associated device

Association group 2 supports 9 nodes.

Group 3: Association Group 3

It is assigned to switch connected to the SW (SW1) terminal (uses Switch Multilevel command class). Triggered by SW (SW1) Supports the following command classes:

  1. SWITCH_MULTILEVEL_START_LEVEL_CHANGE : initiate a transition to a new level (increase or decrease light intensity in case of dimmer, or move shutter up or down, …)

  2. SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE : stop an ongoing transition (stop increase or decrease light intensity in case of dimmer, or stop moving shutter up or down, …)

It is recommended to use push buttons for this association.

Association group 3 supports 9 nodes.

Group 4: Association Group 4

It is assigned to switch connected to the SW2 terminal (uses Basic command class). Triggered by SW2. Supports the following command classes:

BASIC_SET : set On / Off state at the associated device

Association group 4 supports 9 nodes.

Group 5: Association Group 5

It is assigned to switch connected to the SW2 terminal (uses Switch Multilevel command class). Triggered by SW2. Supports the following command classes:

SWITCH_MULTILEVEL_START_LEVEL_CHANGE : initiate a transition to a new level (increase or decrease light intensity in case of dimmer, or move shutter up or down, …)

SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE : stop an ongoing transition (stop increase or decrease light intensity in case of dimmer, or stop moving shutter up or down, …)

It is recommended to use push buttons for this association.

Association group 5 supports 9 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_TRANSPORT_SERVICE_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_INDICATOR_V3
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_SECURITY_2_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1