ZMNHDA Flush dimmer
This describes the Z-Wave device ZMNHDA, manufactured by Goap with the thing type UID of qubino_zmnhda_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZMNHDA supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
This Z-Wave module is used for dimming the bulb or to manage the speed of a fan. The module can be controlled either through a Z-Wave network or through the wall switch.
The module is designed to be mounted inside a “flush mounting box” and is hidden behind a traditional wall switch.
Module measures power consumption of bulb or fan and supports connection of digital temperature sensor.
Inclusion Information
- Connect module to power supply,
- bring module within maximum 1 meter (3 feet) of the main controller,
- enable add/remove mode on main controller,
- auto-inclusion (30 minutes after connected to power supply) or
- press service button S for more than 2 seconds or
- press push button I1 three times within 3s (3 times change switch state within 3 seconds).
Exclusion Information
- Connect module to power supply,
- bring module within maximum 1 meter (3 feet) of the main controller,
- enable add/remove mode on main controller,
- press service button S for more than 6 seconds or
- press push button I1 five times within 3s (5 times change switch state within 3 seconds)
By this function all parameters of the module are set to default values and own ID is deleted.
If service button S is pressed more than 2 and less than 6 second module is excluded, but configuration parameters are not set to default values.
Channels
The following table summarises the channels available for the ZMNHDA -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch [Deprecated] | switch_binary | switch_binary | Switch | Switch |
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Meter reset | meter_reset | meter_reset | Energy | Switch |
Binary Sensor 1 | sensor_binary1 | sensor_binary | Switch | |
Binary Sensor 2 | sensor_binary2 | sensor_binary | Switch |
Switch [Deprecated]
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Note: This channel is marked as deprecated so should not be used.
Dimmer
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Sensor (temperature)
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Electric meter (kWh)
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (watts)
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Meter reset
Reset the meter.
The meter_reset
channel is of type meter_reset
and supports the Switch
item and is in the Energy
category.
Binary Sensor 1
Indicates if a sensor has triggered.
The sensor_binary1
channel is of type sensor_binary
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Binary Sensor 2
Indicates if a sensor has triggered.
The sensor_binary2
channel is of type sensor_binary
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Device Configuration
The following table provides a summary of the 11 configuration parameters available in the ZMNHDA. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Input 1 switch type | Switch type (input I1) |
2 | Input 2 contact type | Input 2 contact type |
3 | Input 3 contact type | Input 3 contact type |
10 | Activate / deactivate functions ALL ON/ALL OFF | Activate / deactivate functions ALL ON/ALL OFF |
30 | State of the device after a power failure | State of the device after a power failure |
40 | Power reporting in Watts on power change | Set value means percentage |
42 | Power reporting in Watts by time interval | Power reporting in Watts by time interval |
60 | Minimum dimming value | Minimum dimming value |
61 | Maximum dimming value | Maximum dimming value |
65 | Dimming time (soft on/off) | Dimming time (soft on/off) |
66 | Dimming time when key pressed | Dimming time when key pressed |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 1: Input 1 switch type
Switch type (input I1)
The following option values may be configured -:
Value | Description |
---|---|
0 | mono-stable switch (push button) |
1 | bi-stable (toggle) switch |
The manufacturer defined default value is 0
(mono-stable switch (push button)).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Input 2 contact type
Input 2 contact type
The following option values may be configured -:
Value | Description |
---|---|
0 | NO (normally open) input type |
1 | NC (normally close) input type |
The manufacturer defined default value is 0
(NO (normally open) input type).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: Input 3 contact type
Input 3 contact type
The following option values may be configured -:
Value | Description |
---|---|
0 | NO (normally open) input type |
1 | NC (normally close) input type |
The manufacturer defined default value is 0
(NO (normally open) input type).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 10: Activate / deactivate functions ALL ON/ALL OFF
Activate / deactivate functions ALL ON/ALL OFF Flush 1 relay module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. The following option values may be configured -:
Value | Description |
---|---|
0 | ALL ON is not active ALL OFF is not active |
1 | ALL ON is not active ALL OFF active |
2 | ALL ON active ALL OFF is not active |
255 | ALL ON active, ALL OFF active |
The manufacturer defined default value is 255
(ALL ON active, ALL OFF active).
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Parameter 30: State of the device after a power failure
State of the device after a power failure
The following option values may be configured -:
Value | Description |
---|---|
0 | Saves its state before power failure |
1 | Off |
The manufacturer defined default value is 0
(Saves its state before power failure).
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
Parameter 40: Power reporting in Watts on power change
Set value means percentage
- 0 – Reporting Disabled
- 1 – 100 = 1% - 100% Reporting enabled.
Power report is send (push) only when actual power in Watts in real time change for more than set percentage comparing to previous actual power in Watts, step is 1%. Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_40_1
and is of type INTEGER
.
Parameter 42: Power reporting in Watts by time interval
Power reporting in Watts by time interval Set value means time interval (0 – 65535) in seconds, when power report is send.
- default value 300 (power report in Watts is send each 300s)
- 0 – Reporting Disabled
- 1 – 65535 = 1 second – 65535 seconds. Reporting enabled.
Power report is send with time interval set by entered value. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 300
.
This parameter has the configuration ID config_42_2
and is of type INTEGER
.
Parameter 60: Minimum dimming value
Minimum dimming value
- Default value 1 (Minimum dimming value is 1%)
- 1- 98 = 1% – 98%, step is 1%. Minimum dimming values is set by entered value.
NOTE: The maximum level may not be lower than the minimum level! 1% min. dimming value is defined by Z-Wave multilevel device class Values in the range 0 to 98 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_60_1
and is of type INTEGER
.
Parameter 61: Maximum dimming value
Maximum dimming value
- Default value 99 (Maximum dimming value is 99 %)
- 2- 99 = 2% – 99%, step is 1%. Maximum dimming values is set by entered value.
NOTE: The maximum level may not be lower than the minimum level! 99% max. dimming value is defined by Z-Wave multilevel device class Values in the range 2 to 99 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_61_1
and is of type INTEGER
.
Parameter 65: Dimming time (soft on/off)
Dimming time (soft on/off) Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through UI.
- Default value 100 (Dimming time between min. and max. dimming values is 1s)
- 1- 255 = 10mseconds – 2550mseconds (2,55s), step is 10mseconds Values in the range 1 to 255 may be set.
The manufacturer defined default value is 100
.
This parameter has the configuration ID config_65_1
and is of type INTEGER
.
Parameter 66: Dimming time when key pressed
Dimming time when key pressed Time of moving the Dimmer between min. and max dimming values by continues hold of push button I1.
Default value 3 (Dimming time between min. and max. dimming values is 3s)
1- 255 = 1 second – 255 seconds Values in the range 1 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_66_1
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZMNHDA supports 4 association groups.
Group 1: multilevel
(triggered at changes of state/value of the Flush dimmer)
Association group 1 supports 4 nodes.
Group 2: basic on/off triggered by the input I2 state
Association group 2 supports 4 nodes.
Group 3: basic on/off triggered by the input I3 state
Association group 3 supports 4 nodes.
Group 4: Controller updates
Association group 4 supports 4 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V3 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Endpoint 1
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | Linked to BASIC |
Endpoint 2
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | Linked to BASIC |
Documentation Links