QZ2140-840 IQ Dimmer (PD-100)
This describes the Z-Wave device QZ2140-840, manufactured by Qolsys with the thing type UID of qolsys_qz2140-840_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The QZ2140-840 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
The IQ Dimmer is plug in lamp module that allows you control a lamp on, off or any degree in between. It plugs into any standard outlet and acts as a repeater to strengthen the performance of your Z-Wave network.
Inclusion Information
-
Place your network controller into inclusion mode by following the controller manufacturer's instructions.
-
When the controller is ready, single press the button on the front of the IQ Dimmer.
Exclusion Information
-
Place your network controller into exclusion mode by following the controller manufacturer's instructions.
-
When the controller is ready, single press the button on the front of the IQ Dimmer.
General Usage Information
Channels
The following table summarises the channels available for the QZ2140-840 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | scene_number | Number |
Dimmer
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Scene Number
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
Device Configuration
The following table provides a summary of the 3 configuration parameters available in the QZ2140-840. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | Nightlight | When should LED be illuminated. When device is on, off or never. |
9 | Dimming Resolution Levels | Percent to change dimmer level per tick. |
10 | Dimming Resolution Speed | The time duration of each tick, in 10 ms units. |
Parameter 3: Nightlight
When should LED be illuminated. When device is on, off or never.
The following option values may be configured, in addition to values in the range 0 to 2 -:
Value | Description |
---|---|
0 | LED ON when device OFF |
1 | LED ON when device ON |
2 | LED Always OFF |
The manufacturer defined default value is 0
(LED ON when device OFF).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 9: Dimming Resolution Levels
Percent to change dimmer level per tick.
Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Parameter 10: Dimming Resolution Speed
The time duration of each tick, in 10 ms units.
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The QZ2140-840 supports 1 association group.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Lifeline association only supports the "manual reset" event.
Association group 1 supports 1 node.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_TRANSPORT_SERVICE_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_SUPERVISION_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_SECURITY_V1 | |
COMMAND_CLASS_SECURITY_2_V1 |
Documentation Links