QZ2101-840 / STW-W3350WU IQ Smart Plug
This describes the Z-Wave device QZ2101-840 / STW-W3350WU, manufactured by Qolsys with the thing type UID of qolsys_qz2101840_00_000.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The QZ2101-840 / STW-W3350WU supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
Smart Plug switch with voltage, power and energy measurement.
-
Technical parameters
-
ON/OFF control
-
Compatible with 300 series and 500 series
-
Measuring voltage, current, instant power, accumulated power.
-
Input voltage: 110-230V AC 50/60HZ
-
Max current: 13A
-
Rated input current: 10A,110-230V ,50/60 Hz Continuous load current
16A,110-230V ,50/60Hz Instantaneous load current
-
Radio Protocol: Z-Wave
-
Radio Frequency: 868.4MHz EU; 908.4MHz US; 921.4MHz ANZ; 869.2MHz RU
-
Wireless distance:50m
-
Operation temperature: 0-40°C
-
Storage temperature:0-60°C
-
Dimension (D x W x H):
-
US plug: 43mm x 43mm x 45mm
-
EU plug: 43mm x 43mm x 65mm (F Type)
Inclusion Information
Set controller to include mode. Quickly, triple click the code button, the device will enter adding mode, and the LED light will flash red 5 times.
Exclusion Information
Set controller to exclude/remove mode. Quickly, triple click the code button, the device will enter adding mode, and the LED light will flash red 5 times.
General Usage Information
The status of LED
- When the power plug is ON, LED light keeps being green.
- When the power plug is OFF, LED light keeps being off.
- Quickly, triple click the code button ,add the power plug to the Z-Wave network or remove it from Z-Wave network , LED light flashes yellow or red for 5 times at the same time.
- Press the code button for 10 seconds, the power plug will be restored to factory default settings, LED light flashes red for 5 time at the same time.
Channels
The following table summarises the channels available for the QZ2101-840 / STW-W3350WU -:
| Channel Name | Channel ID | Channel Type | Category | Item Type |
|---|---|---|---|---|
| Switch | switch_binary | switch_binary | Switch | Switch |
| Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
| Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
| Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
| Electric meter (amps) | meter_current | meter_current | Energy | Number |
| Alarm | alarm_power | alarm_power | Energy | Switch |
Switch
Switch the power on and off.
The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.
Electric meter (kWh)
Indicates the energy consumption (kWh).
The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (watts)
Indicates the instantaneous power consumption.
The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (volts)
Indicates the instantaneous voltage.
The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (amps)
Indicates the instantaneous current consumption.
The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
Alarm
Indicates if a power alarm is triggered.
The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch item type -:
| Value | Label |
|---|---|
| OFF | OK |
| ON | Alarm |
Device Configuration
The following table provides a summary of the 9 configuration parameters available in the QZ2101-840 / STW-W3350WU. Detailed information on each parameter can be found in the sections below.
| Param | Name | Description |
|---|---|---|
| 1 | Meter Report Enable | This parameter defines Disable/Enable meter report measure data to controller. |
| 2 | Meter Report Interval | Interval time reporting data to controller |
| 3 | Maxium over-load current | maximum current the plug can provide to load |
| 4 | Maximum alarm current | Max current for over-current notification |
| 5 | LED enable | This parameter defines the LED indication Function ON/OFF. |
| 6 | Power Report Threshold | Power consumed change to be reported |
| 7 | Remember Relay ON/OFF status after power failure. | Plug state after power-on |
| 8 | Plug Time switch Function | Timer plug OFF after time period |
| 9 | Time switch Period | Delay time after the plug is switched off (in minutes) |
| Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 1: Meter Report Enable
This parameter defines Disable/Enable meter report measure data to controller.
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1.
This parameter has the configuration ID config_1_1 and is of type INTEGER.
Parameter 2: Meter Report Interval
Interval time reporting data to controller This parameter defines interval time (in seconds) that Meter report data to Z-Wave
Controller. Values in the range 1 to 65535 may be set.
The manufacturer defined default value is 300.
This parameter has the configuration ID config_2_3 and is of type INTEGER.
Parameter 3: Maxium over-load current
maximum current the plug can provide to load This parameter defines maximum current the plug can provide to load that be connected to plug. If the current consumed by load greater than maximum current, the plug will cut off power. Values in the range 1 to 13 may be set.
The manufacturer defined default value is 10.
This parameter has the configuration ID config_3_1 and is of type INTEGER.
Parameter 4: Maximum alarm current
Max current for over-current notification This parameter defines maximum current, if the current plug provides to load greater than this parameter, the plug will send over-current notification to Z-Wave Controller and the LED will be turn RED, but plug cannot cut-off power. This value must be less than parameter 3#. Values in the range 1 to 13 may be set.
The manufacturer defined default value is 9.
This parameter has the configuration ID config_4_1 and is of type INTEGER.
Parameter 5: LED enable
This parameter defines the LED indication Function ON/OFF.
The following option values may be configured, in addition to values in the range 0 to 1 -:
| Value | Description |
|---|---|
| 0 | Disable LED indication Function |
| 1 | Enable LED indication Function |
The manufacturer defined default value is 1 (Enable LED indication Function).
This parameter has the configuration ID config_5_1 and is of type INTEGER.
Parameter 6: Power Report Threshold
Power consumed change to be reported This parameter defines by how much power consumed must change to be reported to the Z-Wave Controller or Z-Wave Gateway in percent. If the rate of power consumed change ratio is greater than this parameter, the plug will report the results, voltage, current, power and energy, that plug measure to Z-Wave Controller or Z-Wave Gateway. Values in the range 1 to 100 may be set.
The manufacturer defined default value is 5.
This parameter has the configuration ID config_6_1 and is of type INTEGER.
Parameter 7: Remember Relay ON/OFF status after power failure.
Plug state after power-on This parameter defined the relay status if remember or not. If remembered, the plug will restore the relay status last power off when the plug supply power next time. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1.
This parameter has the configuration ID config_7_1 and is of type INTEGER.
Parameter 8: Plug Time switch Function
Timer plug OFF after time period This parameter defines the timer function Enable/Disable. This parameter can be configured with 0 or 1, where 0 means disable time switch function and 1 enable. The time will be defined in parameter 9#. If this parameter is Set to 1, and when turn the plug relay on, the timer in plug start run with time defined in parameter #9 and the plug will turn the relay off. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0.
This parameter has the configuration ID config_8_1 and is of type INTEGER.
Parameter 9: Time switch Period
Delay time after the plug is switched off (in minutes) This parameter defines the time that plug time switch off. This parameter can be configured 1 ~ 65535(in minutes). If Parameter 9# is set to ‘1’, and relay is turn-on, the relay will be turn-off after delay this parameter. Values in the range 1 to 65535 may be set.
The manufacturer defined default value is 150.
This parameter has the configuration ID config_9_2 and is of type INTEGER.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
| Value | Description |
|---|---|
| 0 | Exclude from All On and All Off groups |
| 1 | Include in All On group |
| 2 | Include in All Off group |
| 255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode and is of type INTEGER.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The QZ2101-840 / STW-W3350WU supports 2 association groups.
Group 1: lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 is assigned to Plugs status - On/Off. Allows for receiving control command from trigger devices whenever the Plug is turned On or Off. Association group 1 is assigned to Plugs status - On/Off. Allows for receiving control command from trigger devices whenever the Plug is turned On or Off.
Association group 1 supports 1 node.
Group 2: group 2
Association group 2 reports relay's status to just one device, Z-Wave network's main controller by default. It's not recommended to modify settings of this association group. Association group 2 reports relay's status to just one device, Z-Wave network's main controller by default. It's not recommended to modify settings of this association group.
Association group 2 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
| Command Class | Comment |
|---|---|
| COMMAND_CLASS_NO_OPERATION_V1 | |
| COMMAND_CLASS_BASIC_V1 | |
| COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
| COMMAND_CLASS_SWITCH_ALL_V1 | |
| COMMAND_CLASS_METER_V3 | |
| COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
| COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
| COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
| COMMAND_CLASS_CONFIGURATION_V1 | |
| COMMAND_CLASS_ALARM_V1 | |
| COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
| COMMAND_CLASS_POWERLEVEL_V1 | |
| COMMAND_CLASS_ASSOCIATION_V2 | |
| COMMAND_CLASS_VERSION_V2 |