openhab-docs/_addons_bindings/zwave/doc/philio/pse04_0_0.md

7.4 KiB

layout title
documentation PSE04 - ZWave

{% include base.html %}

PSE04 Outdoor Siren

This describes the Z-Wave device PSE04, manufactured by Philio Technology Corp with the thing type UID of philio_pse04_00_000.

The device is in the category of Siren, defining Siren used by Alarm systems.

PSE04 product image

The PSE04 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

The PSE04 is outdoor wireless siren with multiple sound capabilities.

Inclusion Information

Put controller into inclusion mode. Press tamper key three times within 1.5 seconds. After device was added successfully, the LED will turn on for 1 second.

Exclusion Information

Put controller into exclusion mode. Press tamper key three times within 1.5 seconds. 

General Usage Information

Channels

The following table summarises the channels available for the PSE04 -:

Channel Name Channel ID Channel Type Category Item Type
Sound basic_number basic_number Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Tamper Notification alarm_burglar alarm_burglar Door Switch
Battery Level battery-level system.battery_level Battery Number

Sound

The basic_number channel is of type basic_number and supports the Number item. This is a read only channel so will only be updated following state changes from the device.

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Tamper Notification

Indicates if the burglar alarm is triggered.

The alarm_burglar channel is of type alarm_burglar and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the PSE04. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Auto Report Tick Interval The interval time for auto report each tick.
2 Sound Duration Play sound duration, 1 tick is 30 seconds.
3 Customer Function Customer function switch, using bit control.
4 Auto Report Temperature Time The interval time for auto report the temperature.
5 Temperature Differential Report The temperature differential to report.
6 Auto Report Battery Time The interval time for auto report the battery level.
7 Play Sound Control Control play sound's level and which sound.

Parameter 1: Auto Report Tick Interval

The interval time for auto report each tick.

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Sound Duration

Play sound duration, 1 tick is 30 seconds.

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 6.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Customer Function

Customer function switch, using bit control. Bit0: Disable Trigger Alarm. 0:Enable , 1:Disable.

Bit1: Disable Sound. Only using optical alarm. 0:Enable ,1:Disable.

Bit2: Temperature Unit. 0:Fahrenheit , 1:Celsius. Values in the range 0 to 7 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Auto Report Temperature Time

The interval time for auto report the temperature.

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Temperature Differential Report

The temperature differential to report.

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Auto Report Battery Time

The interval time for auto report the battery level.

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Play Sound Control

Control play sound's level and which sound. Bit0~1: Play sound's level. Level 1~3, 0: Level 3.

Bit4~7: Which sound id will play, when control form controller. Sound ID 1~6, 0: Disable. Values in the range 0 to 243 may be set.

The manufacturer defined default value is 67.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The PSE04 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V10
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SECURITY_V1

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.