7.4 KiB
layout | title |
---|---|
documentation | PSE04 - ZWave |
{% include base.html %}
PSE04 Outdoor Siren
This describes the Z-Wave device PSE04, manufactured by Philio Technology Corp with the thing type UID of philio_pse04_00_000
.
The device is in the category of Siren, defining Siren used by Alarm systems.
The PSE04 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
Overview
The PSE04 is outdoor wireless siren with multiple sound capabilities.
Inclusion Information
Put controller into inclusion mode. Press tamper key three times within 1.5 seconds. After device was added successfully, the LED will turn on for 1 second.
Exclusion Information
Put controller into exclusion mode. Press tamper key three times within 1.5 seconds.
General Usage Information
Channels
The following table summarises the channels available for the PSE04 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Sound | basic_number | basic_number | Number | |
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Tamper Notification | alarm_burglar | alarm_burglar | Door | Switch |
Battery Level | battery-level | system.battery_level | Battery | Number |
Sound
The basic_number
channel is of type basic_number
and supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
Sensor (temperature)
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Tamper Notification
Indicates if the burglar alarm is triggered.
The alarm_burglar
channel is of type alarm_burglar
and supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
Device Configuration
The following table provides a summary of the 7 configuration parameters available in the PSE04. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Auto Report Tick Interval | The interval time for auto report each tick. |
2 | Sound Duration | Play sound duration, 1 tick is 30 seconds. |
3 | Customer Function | Customer function switch, using bit control. |
4 | Auto Report Temperature Time | The interval time for auto report the temperature. |
5 | Temperature Differential Report | The temperature differential to report. |
6 | Auto Report Battery Time | The interval time for auto report the battery level. |
7 | Play Sound Control | Control play sound's level and which sound. |
Parameter 1: Auto Report Tick Interval
The interval time for auto report each tick.
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Sound Duration
Play sound duration, 1 tick is 30 seconds.
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 6
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: Customer Function
Customer function switch, using bit control. Bit0: Disable Trigger Alarm. 0:Enable , 1:Disable.
Bit1: Disable Sound. Only using optical alarm. 0:Enable ,1:Disable.
Bit2: Temperature Unit. 0:Fahrenheit , 1:Celsius. Values in the range 0 to 7 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: Auto Report Temperature Time
The interval time for auto report the temperature.
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 12
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 5: Temperature Differential Report
The temperature differential to report.
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter 6: Auto Report Battery Time
The interval time for auto report the battery level.
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 12
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Parameter 7: Play Sound Control
Control play sound's level and which sound. Bit0~1: Play sound's level. Level 1~3, 0: Level 3.
Bit4~7: Which sound id will play, when control form controller. Sound ID 1~6, 0: Disable. Values in the range 0 to 243 may be set.
The manufacturer defined default value is 67
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The PSE04 supports 1 association group.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V10 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ALARM_V8 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_SECURITY_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.