ZPR-111 Plug-in Switch with enery meter

This describes the Z-Wave device ZPR-111, manufactured by Nexa with the thing type UID of nexa_zpr111_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

ZPR-111 product image

The ZPR-111 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Z-Wave plugin receiver (On/Off) with power consumption measurement function, LED indicator, built-in switch-off timer and on/off button.

Inclusion Information

Press the link button three times within 1.5 seconds; the LED flashes Yellow 5 times.

Exclusion Information

Press the link button three times within 1.5 seconds: the LED flashes Purple 5 times.

General Usage Information

Note:

  • Voltage is only measured when the switch is on

  • Energy consumed sometimes reports -21474831.9 kWh

  • Amp meter does not report very low current, for example 1.5W LED reports 0

Channels

The following table summarises the channels available for the ZPR-111 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Alarm (power) alarm_power alarm_power Energy Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the ZPR-111. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Send meter report enable This parameter defines Enable/Disable meter report measure data to controller (default Enable).
2 Meter report interval Defines the time interval that meter report data to main controller (default 300s).
3 Upper current threshold Defines the maximum current before the plug will cut off power (default 13A).
4 Upper current threshold alarm Defines the over current alarm threshold (default 12A)
5 Led display enable Defines the LED indication function ON/OFF (default ON).
6 Power reporting setting Defines by how much consumed power must change to be reported to the Z-Wave Controller (default 30%).
7 Remember relay status Defines if the relay status is remembered or not after a power cut (default Remember).
8 Time switch enable/disable Defines switch timer function Enable/Disable (default Disable).
9 Time switch period Defines the time period before the plug is switched off (default 150m).

Parameter 1: Send meter report enable

This parameter defines Enable/Disable meter report measure data to controller (default Enable).

The following option values may be configured, in addition to values in the range 0 to 0 -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 1 (Enable).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Meter report interval

Defines the time interval that meter report data to main controller (default 300s).

Values in the range 1 to 65535 may be set.

The manufacturer defined default value is 300.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Upper current threshold

Defines the maximum current before the plug will cut off power (default 13A). This parameter defines maximum current the plug can provide to load that be connected to plug. If the current consumed by load greater than maximum current, the plug will cut off power. Values in the range 1 to 16 may be set.

The manufacturer defined default value is 13.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Upper current threshold alarm

Defines the over current alarm threshold (default 12A) This parameter defines maximum current. If the current the plug provides to the load is greater than this parameter, the plug will send over-current notification to main controller and the LED will be turn RED. This value must be less than parameter #3. Values in the range 1 to 16 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Led display enable

Defines the LED indication function ON/OFF (default ON).

The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Off
1 On

The manufacturer defined default value is 1 (On).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Power reporting setting

Defines by how much consumed power must change to be reported to the Z-Wave Controller (default 30%). This parameter defines by how much power consumed must change to be reported to the Z-Wave Controller or Z-Wave Gateway, in percents.

If the rate of power consumed change ratio is greater than this parameter, the plug will report the results, voltage, current, power and energy, that plug measure to Z-Wave Controller or Z-Wave Gateway.  Values in the range 1 to 100 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Remember relay status

Defines if the relay status is remembered or not after a power cut (default Remember). This parameter defined the relay status if remember or not. If remembered, the plug will restore the relay status last power off when the plug supply power next time. The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Do not Remember
1 Remember

The manufacturer defined default value is 1 (Remember).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Time switch enable/disable

Defines switch timer function Enable/Disable (default Disable). This parameter defines the timer function Enable/Disable. The time period will be defined in parameter #9. If this parameter is set to 1, and when turn the plug relay on, the timer in plug start run with time period defined in parameter #9 and the plug will turn the relay off. The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Time switch period

Defines the time period before the plug is switched off (default 150m). This parameter defines the time period that plug time switch off.

If Parameter #8 is set to 1, and relay is turn-on, the relay will be turn-off after delay this parameter. Values in the range 1 to 65535 may be set.

The manufacturer defined default value is 150.

This parameter has the configuration ID config_9_2 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZPR-111 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_TRANSPORT_SERVICE_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_SECURITY_2_V1