SR-ZV9032A Multisensor
This describes the Z-Wave device SR-ZV9032A, manufactured by Namron with the thing type UID of namron_srzv9032a_00_000
.
The device is in the category of Battery, defining Batteries, Energy Storages.
The SR-ZV9032A supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The SR-ZV9032A does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
Overview
The Z-Wave MultiSensor is a wireless, battery powered Z-Wave multi-sensor,
compatible with the Z-Wave Plus standard. The sensor combines 4 different sensors in one device: motion sensor, daylight sensor, temperature sensor and humidity sensor. It is developed to detect ambient values and movement and to transmit them with Z-Wave Plus.
The MultiSensor is designed to be installed quickly and easily on any surface with 3M tape or screws. The LED indicator signals motion, operating mode and can be used to see if device is within the Z-Wave network. The MultiSensor can be used for lighting scenes and presence monitoring systems. This device can be easily integrated into existing standard 55mm frames and installed on the wall with the bracket, or you can put it on the desk as a portable sensor.
The encryption modes that the sensor supports are S0, S2 Unauthenticated. When the motion sensor is being included into a Z-Wave network, you can use your primary controller/gateway to enable one encryption mode or disable encryption. (The primary controller/gateway shall support encryption mode configuration).
Inclusion Information
- Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion).
- Make sure the sensor does not belong to any Z-Wave network. If the sensor has already been included into a network, it shall be removed from the network first. There
are two methods to set the sensor into inclusion mode:
- Triple press the action button on the sensor, it will set the sensor into inclusion mode.
- Make sure that the sensor does not belong to any Z-Wave network, remove battery of the sensor and re-install again to reset power of the sensor, it will be set into inclusion mode automatically, and waiting to be included.
The LED indicator will flash fast to indicate successful inclusion.
Note: During inclusion process, triple press the action button 3 times again will enable the sensor to exit inclusion mode
Exclusion Information
There are two exclusion methods:
Method 1: Exclusion from the primary controller/gateway as follows:
- Set the primary controller/gateway into exclusion mode (Please refer to your primarycontrollers manual on how to set your controller into exclusion).
- Triple press the action button, the sensor will be set to exclusion mode, the LEDindicator will flash fast and then the sensor will be removed from the network and reset to factory defaults.
Note: During exclusion process, triple press the action button 3 times again will enable the sensor to exit exclusion mode.
Method 2: Factory reset the sensor will force it to be excluded from a network. (please refer to the part “Factory Reset” of this manual)
Wakeup Information
The SR-ZV9032A does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
Press and hold action button for 1 second to send Wakeup Notification CC to lifeline.
General Usage Information
Channels
The following table summarises the channels available for the SR-ZV9032A -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Sensor (luminance) | sensor_luminance | sensor_luminance | Number | |
Sensor (relative humidity) | sensor_relhumidity | sensor_relhumidity | Humidity | Number |
Alarm (burglar) | alarm_burglar | alarm_burglar | Door | Switch |
Battery Level | battery-level | system.battery_level | Battery | Number |
Sensor (temperature)
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Sensor (luminance)
Indicates the current light reading.
The sensor_luminance
channel is of type sensor_luminance
and supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
Sensor (relative humidity)
Indicates the current relative humidity.
The sensor_relhumidity
channel is of type sensor_relhumidity
and supports the Number
item and is in the Humidity
category. This is a read only channel so will only be updated following state changes from the device.
Alarm (burglar)
Indicates if the burglar alarm is triggered.
The alarm_burglar
channel is of type alarm_burglar
and supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
Device Configuration
The following table provides a summary of the 19 configuration parameters available in the SR-ZV9032A. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
2 | Battery treshold | Battery treshold |
3 | Motion detection sensitivity | Motion detection sensitivity. |
4 | Motion detection blind time | Motion detection blind time |
5 | Motion detection - pulse counter | Motion detection - pulse counter |
6 | Motion detection - window time. | Motion detection - window time. |
7 | Motion detection - alarm cancellation delay | Motion detection - alarm cancellation delay |
8 | Basic Command | BASIC command class configuration. |
9 | PIR Sensor ON value | PIR Sensor Basic Value - ON |
10 | PIR Sensor OFF value | PIR Sensor Basic Value - OFF |
11 | Motion detect - mode | Motion detect mode - Time of day |
12 | Motion detect - night-day | Motion detect - Difference between night and day |
13 | Illuminance report interval | Time interval between consecutive illuminance reports |
14 | Illuminance report - threshold | Illuminance report - threshold |
15 | Associations in Z-Wave network Security Mode | Associations in Z-Wave network Security Mode |
16 | Time interval to report temperature, humidity | Time interval to report temperature, humidity |
17 | Temperature sensor value change threshold | Temperature sensor value change threshold |
18 | Humidity sensor value change threshold | Humidity sensor value change threshold |
19 | Temperature compensation | Temperature compensation |
20 | Humidity compensation | Humidity compensation |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
Parameter 2: Battery treshold
Battery treshold Threshold value to send battery report.
When battery power change value is over the threshold
value, send Battery Report to Lifeline.
Available settings: 1~50 Values in the range 1 to 50 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: Motion detection sensitivity
Motion detection sensitivity. Motion detection sensitivity.
0: PIR sensor is disabled.
8-255: PIR sensor is enabled. The lower the value, the
more sensitive the PIR sensor is.
Available settings: 0 & 8~255 Values in the range 0 to 255 may be set.
The manufacturer defined default value is 15
.
This parameter has the configuration ID config_3_2
and is of type INTEGER
.
Parameter 4: Motion detection blind time
Motion detection blind time Motion detection blind time (unit is 0.5S).
PIR sensor is "blind" (insensitive) to motion after last
detection for the amount of time specified in this
parameter.
Shorter time periods allow to detect motion more
frequently, but the battery will be drained faster.
Available settings: 0-15 (0.5-8 seconds, time [s] = 0.5 x
(value+1) Values in the range 0 to 15 may be set.
The manufacturer defined default value is 15
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 5: Motion detection - pulse counter
Motion detection - pulse counter Motion detection - pulse counter.
This parameter determines the number of moves required
for the PIR sensor to report motion. The higher the value,
the less sensitive the PIR sensor is.
It is not recommended to modify this parameter settings!
Available settings: 0~3
0: 1 pulse
1: 2 pulses
2: 3 pulses
3: 4 pulses Values in the range 0 to 3 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter 6: Motion detection - window time.
Motion detection - window time. Motion detection - window time.
Period of time during which the number of moves set in parameter 5 must be detected in order for the PIR sensor to report motion. The higher the value, the more sensitive the PIR sensor is.
It is not recommended to modify this parameter settings!
Available settings: 0~3
0: 4 seconds
1: 8 seconds
2: 12 seconds
3: 16 seconds Values in the range 0 to 3 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Parameter 7: Motion detection - alarm cancellation delay
Motion detection - alarm cancellation delay Motion detection - alarm cancellation delay.
Time period after which the motion alarm will be cancelled
in the gateway controller and associated devices.
If there is no motion triggered during this period, the
following commands will be sent to the associated devices:
- Send Notification to Lifeline(Notification Type is Home
Security, Event is 0, Parameter 1 is Motion Detection
Unknown Location)
- Send BASIC OFF to group 2, the value is defined by
parameter 10.
Any motion detected during this period resets the timer.
Available settings: 3-28800 (in seconds) Values in the range 3 to 28800 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_7_2
and is of type INTEGER
.
Parameter 8: Basic Command
BASIC command class configuration. BASIC command class configuration.
This parameter determines the command frames sent to
2nd association group (assigned to PIR sensor).
Available settings: 0~2
0: Both BASIC On and OFF command frames sent in Basic
Command Class
1: Only the BASIC On command frame sent in Basic
Command Class when motion event is triggered
2:Only the BASIC OFF command frame sent in Basic
Command Class when motion event is cleared Values in the range 0 to 2 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Parameter 9: PIR Sensor ON value
PIR Sensor Basic Value - ON PIR Sensor - value of BASIC ON command sent to 2nd
association group.
This parameter determines value of BASIC ON command
sent to 2nd association group when motion event
triggered.
Available settings: 0~99 & 255 Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_9_2
and is of type INTEGER
.
Parameter 10: PIR Sensor OFF value
PIR Sensor Basic Value - OFF PIR Sensor - value of BASIC OFF command sent to 2nd
association group.
This parameter determines value of BASIC OFF command
sent to 2nd association group when motion event
cleared.
Available settings: 0~99 & 255 Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_10_2
and is of type INTEGER
.
Parameter 11: Motion detect - mode
Motion detect mode - Time of day Motion detection - operating mode
This parameter determines in which part of day the PIR
sensor will be active.
Available settings: 0~2
0: PIR sensor always active
1: PIR sensor active during the day only
2: PIR sensor active during the night only Values in the range 0 to 2 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Parameter 12: Motion detect - night-day
Motion detect - Difference between night and day Motion detection - night/day
This parameter defines the difference between night and
day in terms of light intensity, used in parameter 11.
Available settings: 1~32767 (1~32767 lux) Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 200
.
This parameter has the configuration ID config_12_2
and is of type INTEGER
.
Parameter 13: Illuminance report interval
Time interval between consecutive illuminance reports Illuminance report - interval
Time interval between consecutive illuminance reports.
The reports are sent based on the interval.
Available settings: 5-2678400 (31 days = 31*24*3600=
When the value is set as 0, the reports will not be sent
periodically. Values in the range 5 to 2678400 may be set.
The manufacturer defined default value is 3600
.
This parameter has the configuration ID config_13_4
and is of type INTEGER
.
Parameter 14: Illuminance report - threshold
Illuminance report - threshold Illuminance report - threshold
This parameter determines the change in light intensity
level resulting in illuminance report being sent to the main
controller. (The change in light intensity will only be
detected when the PIR is triggered or the time interval set
in parameter 13 elapsed.)
Available settings: 1~32767 (1~32767 lux)
When the value is set as 0, the threshold does not work. Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 100
.
This parameter has the configuration ID config_14_2
and is of type INTEGER
.
Parameter 15: Associations in Z-Wave network Security Mode
Associations in Z-Wave network Security Mode Associations in Z-Wave network Security Mode
This parameter defines how commands are sent in
specified association groups: as secure or non-secure.
Parameter is active only in Z-Wave network security mode.
It does not apply to 1st group “Lifeline”.
Available settings:
0: 2nd group sent as un-secure
1: 2nd group sent as secure Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
Parameter 16: Time interval to report temperature, humidity
Time interval to report temperature, humidity Time interval to report temperature, humidity (unit is S)
Temperature report and humidity report will be sent based
on the time interval value periodically.
Available settings: 5-2678400 (31 days = 31*24*3600=
When the value is set as 0, the reports will not be sent
periodically. Values in the range 5 to 2678400 may be set.
The manufacturer defined default value is 3600
.
This parameter has the configuration ID config_16_4
and is of type INTEGER
.
Parameter 17: Temperature sensor value change threshold
Temperature sensor value change threshold Temperature sensor value change threshold (unit is 0.1
degree celsius)
Report temperature value automatically when temperature
change exceeds the threshold. (temperature change only
detected when PIR is triggered or time of parameter 16
expires )
Available settings: 0-255, value 0 means the threshold is
disabled.
10 is 1.0 C Values in the range 0 to 255 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_17_2
and is of type INTEGER
.
Parameter 18: Humidity sensor value change threshold
Humidity sensor value change threshold Humidity sensor value change threshold
Report humidity value automatically when humidity change
exceeds the threshold. (humidity change only detected
when PIR is triggered or time of parameter 16 expires )
Available settings: 0-127, value 0 means the threshold is
disabled.
5 = 5% Values in the range 0 to 127 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_18_2
and is of type INTEGER
.
Parameter 19: Temperature compensation
Temperature compensation Temperature compensation (unit is 0.1 degree celsius)
Available settings: -1000~1000(-100℃~100℃) Values in the range -1000 to 1000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_19_2
and is of type INTEGER
.
Parameter 20: Humidity compensation
Humidity compensation Humidity compensation
Available settings: -100~100 Values in the range -100 to 100 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
Wakeup Interval
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The SR-ZV9032A supports 2 association groups.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Lifeline
- When factory reset the sensor, send "Device Reset Locally
Notification CC" to associated devices of this group to report
factory reset information.
- When motion detected, send "Notification Report" to
associated devices of this group.
- Send " Sensor Multilevel Report" to associated devices of
this group.
- Send " Battery Report" to associated devices of this group.
Association group 1 supports 5 nodes.
Group 2: Motion
MotionDetect When motion detected, send “Basic Set 0xFF/0x00” to associated
devices of this group.
Association group 2 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_TRANSPORT_SERVICE_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_SUPERVISION_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V8 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_INDICATOR_V3 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | |
COMMAND_CLASS_SECURITY_V1 | |
COMMAND_CLASS_SECURITY_2_V1 |