9.0 KiB
layout | title |
---|---|
documentation | MH6-HP - ZWave |
{% include base.html %}
MH6-HP Programmable Thermostat
This describes the Z-Wave device MH6-HP, manufactured by McoHome Technology Co., Ltd with the thing type UID of mcohome_mh6hp_02_000
.
This version of the device is limited to firmware versions above 2.0
The device is in the category of HVAC, defining Air condition devices, Fans.
The MH6-HP supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
MH6-HP programmable thermostat is a Z-Wave Plus enabled device for indoor temperature control. It is mainly applied to heat pump system for heating/cooling, with 3 modes easily switchable: Schedule, Hold and Holiday. The device is of high reliability and practicability, and it can support up to 3H/2C system. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers.
Inclusion Information
In normal display, press and hold ^ button to enter interface for adding Z-Wave network. Before device added into network, “- - -” will display on the screen. Then press ^ once, device will enter learning mode to get a node ID. If adding is successful, a Node ID will display on the screen in a few seconds.
Exclusion Information
In normal display, press and hold ^ button to enter interface for removing of Z-Wave network. A Node ID will display on the screen. Then press ^ button once, “- - -” will display on the screen to show removal was successful.
Channels
The following table summarises the channels available for the MH6-HP -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
Operating State | thermostat_state | thermostat_state | Temperature | Number |
Setpoint (cooling) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Thermostat fan mode | thermostat_fanmode | thermostat_fanmode | ||
Thermostat fan state | thermostat_fanstate | thermostat_fanstate | ||
Clock Time Offset | time_offset | time_offset | Time | Number |
Sensor (temperature)
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Thermostat mode
Sets the thermostat.
The thermostat_mode
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Operating State
Sets the thermostat operating state.
The thermostat_state
channel is of type thermostat_state
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Setpoint (cooling)
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Setpoint (heating)
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Thermostat fan mode
Channel type information on this channel is not found.
Thermostat fan state
Channel type information on this channel is not found.
Clock Time Offset
Provides the current time difference for the devices time.
The time_offset
channel is of type time_offset
and supports the Number
item and is in the Time
category.
Device Configuration
The following table provides a summary of the 6 configuration parameters available in the MH6-HP. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Upload temperature format automatically | Upload temperature format automatically |
2 | Upload temperature and humidity automatically | Upload temperature and humidity automatically |
3 | Upload temperature difference | Upload temperature difference |
4 | Upload time interval regularly | Upload time interval regularly |
5 | Upload humidity difference | Upload humidity difference |
255 | Factory reset | Factory reset |
Parameter 1: Upload temperature format automatically
Upload temperature format automatically
Values in the range 0 to 2 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Upload temperature and humidity automatically
Upload temperature and humidity automatically
Values in the range 0 to 3 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: Upload temperature difference
Upload temperature difference Base on 0.1℃unit, 0x0005 by default, 5*0.1℃=0.5℃, 0x0003~0x03E8 (3-1000) Values in the range 3 to 1000 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_3_2
and is of type INTEGER
.
Parameter 4: Upload time interval regularly
Upload time interval regularly
Values in the range 10 to 65535 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_4_2
and is of type INTEGER
.
Parameter 5: Upload humidity difference
Upload humidity difference
Values in the range 2 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter 255: Factory reset
Factory reset 0x55 (85) Restore the factory setting(write only)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 85 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_255_1_wo
and is of type INTEGER
.
This is a write only parameter.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The MH6-HP supports 1 association group.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 1 node.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_TIME_V1 | |
COMMAND_CLASS_TIME_PARAMETERS_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.