MH6-HP Programmable Thermostat

This describes the Z-Wave device MH6-HP, manufactured by McoHome Technology Co., Ltd with the thing type UID of mcohome_mh6hp_02_000. This version of the device is limited to firmware versions above 2.0

The device is in the category of HVAC, defining Air condition devices, Fans.

MH6-HP product image

The MH6-HP supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

MH6-HP programmable thermostat is a Z-Wave Plus enabled device for indoor temperature control. It is mainly applied to heat pump system for heating/cooling, with 3 modes easily switchable: Schedule, Hold and Holiday. The device is of high reliability and practicability, and it can support up to 3H/2C system. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers.

Inclusion Information

In normal display, press and hold ^ button to enter interface for adding Z-Wave network. Before device added into network, “- - -” will display on the screen. Then press ^ once, device will enter learning mode to get a node ID. If adding is successful, a Node ID will display on the screen in a few seconds.

Exclusion Information

In normal display, press and hold ^ button to enter interface for removing of Z-Wave network. A Node ID will display on the screen. Then press ^ button once, “- - -” will display on the screen to show removal was successful.

Channels

The following table summarises the channels available for the MH6-HP -:

Channel Name Channel ID Channel Type Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Operating State thermostat_state thermostat_state Temperature Number
Setpoint (cooling) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Thermostat fan mode thermostat_fanmode thermostat_fanmode
Thermostat fan state thermostat_fanstate thermostat_fanstate
Clock Time Offset time_offset time_offset Time Number

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Operating State

Sets the thermostat operating state.

The thermostat_state channel is of type thermostat_state and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (cooling)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Thermostat fan mode

Channel type information on this channel is not found.

Thermostat fan state

Channel type information on this channel is not found.

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel is of type time_offset and supports the Number item and is in the Time category.

Device Configuration

The following table provides a summary of the 6 configuration parameters available in the MH6-HP. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Upload temperature format automatically Upload temperature format automatically
2 Upload temperature and humidity automatically Upload temperature and humidity automatically
3 Upload temperature difference Upload temperature difference
4 Upload time interval regularly Upload time interval regularly
5 Upload humidity difference Upload humidity difference
255 Factory reset Factory reset

Parameter 1: Upload temperature format automatically

Upload temperature format automatically

Values in the range 0 to 2 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Upload temperature and humidity automatically

Upload temperature and humidity automatically

Values in the range 0 to 3 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Upload temperature difference

Upload temperature difference Base on 0.1℃unit, 0x0005 by default, 5*0.1℃=0.5℃, 0x0003~0x03E8 (3-1000) Values in the range 3 to 1000 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_3_2 and is of type INTEGER.

Parameter 4: Upload time interval regularly

Upload time interval regularly

Values in the range 10 to 65535 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: Upload humidity difference

Upload humidity difference

Values in the range 2 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 255: Factory reset

Factory reset 0x55 (85) Restore the factory setting(write only)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 85 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_255_1_wo and is of type INTEGER. This is a write only parameter.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The MH6-HP supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_TIME_V1
COMMAND_CLASS_TIME_PARAMETERS_V1

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.