ZW6HD Scene Capable Dimmer
This describes the Z-Wave device ZW6HD, manufactured by Leviton with the thing type UID of leviton_zw6hddimer_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZW6HD supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
Z-Wave 800 Series. Supports 300W LED, 300W CFL, 600W Incandescent/Halogen, 600VA Magnetic Low Voltage
Inclusion Information
Network Wide Inclusion:
Network Wide Inclusion allows your device to be included into the network using devices already in the network to assist with communication. Work your way from the closest devices to the controller outward.
Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator LED will blink amber.
Tap the top of the paddle one time. The Locator LED will quickly ash green.
The Decora SmartTM Z-Wave® device is ready to learn into the Z-Wave® network.
Follow directions in the Z-Wave controller to complete the adding process.
Upon successful addition to network the LED will turn off and then blink green 3 times.
If the adding process is not successful the LED will ash red 3 times.
Traditional Inclusion:
For older controllers Traditional Inclusion is supported. Depending on the age of the controller the controller will need to be 3 to 35 feet from the device when including.
Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator LED will blink amber.
The Decora Smart Z-Wave® device is ready to add to the Z-Wave® network.
Follow directions in the Z-Wave® controller to enter learn mode.
Tap the top of the paddle one time. The Locator LED will quickly ash green. The Z-Wave® controller will begin to pair with the Decora Smart device.
Upon successful addition to the network the LED will turn off and then blink green 3 times.
If the adding process is not successful the LED will ash red 3 times.
Exclusion Information
When removing a device from a Z-Wave® network best practice is to use the exclusion command found in the Z-Wave® controller.
Enter Programming Mode by holding the top of the paddle for 7 seconds, the Locator LED will blink amber.
Follow directions in the Z-Wave® controller to enter exclusion mode.
Tap the top of the paddle one time. The Locator LED will quickly flash green. The Z-Wave® controller will exclude the Decora Smart device.
The Z-Wave® controller will confirm successful exclusion from the network.
General Usage Information
Rocker:
• Press the top to turn the light ON.
• Press the bottom to turn the light OFF.
• Double press the top to turn ON at maximum brightness with no fade.
• Double press the bottom to turn OFF with no fade.
Channels
The following table summarises the channels available for the ZW6HD -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | scene_number | Number |
Dimmer
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Scene Number
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
Device Configuration
The following table provides a summary of the 9 configuration parameters available in the ZW6HD. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Fade ON Time | Fade on time |
2 | Fade OFF Time | Fade off time |
3 | Minimum Dim Light Level | Minimum dim light level |
4 | Maximum Brightness Light Level | Maximum brightness light level |
5 | Preset Light Level or Return To Last Level | Preset light level or return to last level |
6 | LED dim/bright bar behavior | LED dim/bright bar behavior |
7 | Status LED configuration | Status LED configuration |
8 | Bulb type | Bulb type |
9 | Control timing | Control timing |
Parameter 1: Fade ON Time
Fade on time • 0 = Instant ON
• 1 - 127 = Seconds: 1 – 127 seconds
• 128 – 253 = Minutes: 1 -126 minutes Values in the range 0 to 253 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_1_4
and is of type INTEGER
.
Parameter 2: Fade OFF Time
Fade off time • 0 = Instant ON
• 1 - 127 = Seconds: 1 – 127 seconds
• 128 – 253 = Minutes: 1 -126 minutes Values in the range 0 to 253 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_2_4
and is of type INTEGER
.
Parameter 3: Minimum Dim Light Level
Minimum dim light level
Values in the range 0 to 99 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_3_4
and is of type INTEGER
.
Parameter 4: Maximum Brightness Light Level
Maximum brightness light level
Values in the range 0 to 99 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_4_4
and is of type INTEGER
.
Parameter 5: Preset Light Level or Return To Last Level
Preset light level or return to last level • 0 = Return to last level
• 1 - 99 = Preset light level Values in the range 0 to 99 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_5_4
and is of type INTEGER
.
Parameter 6: LED dim/bright bar behavior
LED dim/bright bar behavior • 0 = Level Indicators Off
• 1 - 254 = Level Indicator Timeout (seconds)
• 255 = Levels Always ON Values in the range 0 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_6_4
and is of type INTEGER
.
Parameter 7: Status LED configuration
Status LED configuration • 0 = Status LED OFF
• 254 = Status LED ON when load is ON
• 255 = Status LED ON when load is OFF (locator mode) Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_7_4
and is of type INTEGER
.
Parameter 8: Bulb type
Bulb type • 0 = Incandescent
• 1 = LED
• 2 = CFL
• 3 = MLV Values in the range 0 to 3 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_8_0
and is of type INTEGER
.
Parameter 9: Control timing
Control timing • 0 = Normal
• 1 = Medium
• 2 = Extended Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_9_4
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZW6HD supports 3 association groups.
Group 1: Group 1
Lifeline • A notification is sent to the nodes in this association group when
a Lifeline event occurs.
• All nodes in the association group receive notification of Status
changes
Association group 1 supports 5 nodes.
Group 2: Group 2
Multilevel switch set • All nodes in the association group receive a command based on
ON/OFF button presses
Association group 2 supports 5 nodes.
Group 3: Group 3
Basic set • All nodes in the association group receive a command based on
ON/OFF button presses
Association group 3 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_TRANSPORT_SERVICE_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_SUPERVISION_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_INDICATOR_V3 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | |
COMMAND_CLASS_SECURITY_2_V1 |
Documentation Links