TD11010 Roller Shutter Controller

This describes the Z-Wave device TD11010, manufactured by Good Way Technology Co., Ltd with the thing type UID of goodway_td11010_00_000.

The device is in the category of Blinds, defining Roller shutters, window blinds, etc..

TD11010 product image

The TD11010 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Z-Wave Roller Shutter Controller is an ideal for the remotely electric motor controller. It is used to control the motors of rollers, shades, blinds, venetian blinds and similar sun shade, which are single phase AC powered. The module can be controlled either through a Z-Wave network or through the wall switch, and measures power consumption of motor.

Inclusion Information

  1. Put the Z-Wave Controller into inclusion mode, and press the pairing button 3 times in 2 seconds to include the module.
  2. Put the Z-Wave Controller into inclusion mode, and press the external swtich1 or external swtich2 3 times in 2 seconds to include the module.

Exclusion Information

  1. Put the Z-Wave Controller into exclusion mode, and press the pairing button 3 times in 2 seconds to exclude the device.
  2. Put the Z-Wave Controller into inclusion mode, and press the external swtich1 or external swtich2 3 times in 2 seconds to exclude the module.

General Usage Information

Channels

The following table summarises the channels available for the TD11010 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Blinds controls blinds_control blinds_control Blinds Rollershutter
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Blinds controls

Provides start / stop control of blinds.

The blinds_control channel is of type blinds_control and supports the Rollershutter item and is in the Blinds category.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 12 configuration parameters available in the TD11010. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Positioning Calibration Positioning Calibration
2 External switch Protection External switch Protection
3 Delay time for automatic closing When the door is opened, set the delay time for automatic closing
4 Delay time for automatic notification When the door is open, set the delay time for automatic notification
5 Set the operation mode Set the operation mode
6 Angles of blinds Set the angle of blinds
7 Slats turning time Set the slats turning time
8 Delay time to start the motor up to the blade Set the delay time to start the motor up to the blade
9 Delay time to start the motor down to the blade Set the delay time to start the motor down to the blade
10 Power changed percentage to send the power report Set the power changed percentage to send the power report
11 Time interval of reporting watts in seconds Set the time interval of reporting watts in seconds
12 Time interval of reporting KWH in seconds Set the time interval of reporting KWH in seconds

Parameter 1: Positioning Calibration

Positioning Calibration

The following option values may be configured -:

Value Description
0 Disable
1 Executing calibration

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: External switch Protection

External switch Protection

The following option values may be configured -:

Value Description
0 Enable external switch
1 Disable external switch

The manufacturer defined default value is 0 (Enable external switch).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Delay time for automatic closing

When the door is opened, set the delay time for automatic closing 0: Disable automatic closing

1 - 32767: The door will be closed automatically in 1 - 32767sec Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_3_2 and is of type INTEGER.

Parameter 4: Delay time for automatic notification

When the door is open, set the delay time for automatic notification 0: Disable automatic notification

1 - 32767: The notification will be sent automatically in 1 - 32767 sec Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: Set the operation mode

Set the operation mode

The following option values may be configured -:

Value Description
0 Roller Shutter
1 Venetian (up/down and slate rotation)

The manufacturer defined default value is 0 (Roller Shutter).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Angles of blinds

Set the angle of blinds 00∘

130∘

260∘

390∘

4120∘

5150∘

6180 The following option values may be configured -:

Value Description
0 0 degree
1 30 degree
2 60 degree
3 90 degree
4 120 degree
5 150 degree
6 180 degree

The manufacturer defined default value is 0 (0 degree).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Slats turning time

Set the slats turning time 0Disable

1 - 127: 0.1 - 12.7 sec Values in the range 0 to 127 may be set.

The manufacturer defined default value is 15.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Delay time to start the motor up to the blade

Set the delay time to start the motor up to the blade 0No offset time

1 - 127: 0.1 - 12.7 sec Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Delay time to start the motor down to the blade

Set the delay time to start the motor down to the blade 0No offset time

1 - 127: 0.1 12.7 sec Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Power changed percentage to send the power report

Set the power changed percentage to send the power report 0Disabled

1 - 100: 1% - 100% Values in the range 0 to 100 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Time interval of reporting watts in seconds

Set the time interval of reporting watts in seconds 0Disable

60 - 32767: 60 - 32767sec Values in the range 60 to 32767 may be set.

The manufacturer defined default value is 300.

This parameter has the configuration ID config_11_2 and is of type INTEGER.

Parameter 12: Time interval of reporting KWH in seconds

Set the time interval of reporting KWH in seconds 0Disable

60 - 32767: 60 - 32767sec Values in the range 60 to 32767 may be set.

The manufacturer defined default value is 3600.

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The TD11010 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_METER_V3
COMMAND_CLASS_TRANSPORT_SERVICE_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_SECURITY_2_V1