TD13010 In wall Power Monitor Switch
This describes the Z-Wave device TD13010, manufactured by Good Way Technology Co., Ltd with the thing type UID of goodway_TD13010_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The TD13010 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
This In-wall Power Monitor Switch is a transceiver which is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Mini-size
Inclusion Information
Include/Exclude Button - Inclusion/exclusion, press 3 times in 2 seconds
Exclusion Information
Include/Exclude Button - Inclusion/exclusion, press 3 times in 2 seconds
General Usage Information
Channels
The following table summarises the channels available for the TD13010 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Alarm (power) | alarm_power | alarm_power | Energy | Switch |
Switch 1 | switch_binary1 | switch_binary | Switch | Switch |
Electric meter (watts) 1 | meter_watts1 | meter_watts | Energy | Number |
Electric meter (kWh) 1 | meter_kwh1 | meter_kwh | Energy | Number |
Electric meter (volts) 1 | meter_voltage1 | meter_voltage | Energy | Number |
Electric meter (amps) 1 | meter_current1 | meter_current | Energy | Number |
Switch 2 | switch_binary2 | switch_binary | Switch | Switch |
Electric meter (watts) 2 | meter_watts2 | meter_watts | Energy | Number |
Electric meter (kWh) 2 | meter_kwh2 | meter_kwh | Energy | Number |
Electric meter (volts) 2 | meter_voltage2 | meter_voltage | Energy | Number |
Electric meter (amps) 2 | meter_current2 | meter_current | Energy | Number |
Switch
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Electric meter (watts)
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (kWh)
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (volts)
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (amps)
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Alarm (power)
Indicates if a power alarm is triggered.
The alarm_power
channel is of type alarm_power
and supports the Switch
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Switch 1
Switch the power on and off.
The switch_binary1
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Electric meter (watts) 1
Indicates the instantaneous power consumption.
The meter_watts1
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (kWh) 1
Indicates the energy consumption (kWh).
The meter_kwh1
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (volts) 1
Indicates the instantaneous voltage.
The meter_voltage1
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (amps) 1
Indicates the instantaneous current consumption.
The meter_current1
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Switch 2
Switch the power on and off.
The switch_binary2
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Electric meter (watts) 2
Indicates the instantaneous power consumption.
The meter_watts2
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (kWh) 2
Indicates the energy consumption (kWh).
The meter_kwh2
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (volts) 2
Indicates the instantaneous voltage.
The meter_voltage2
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (amps) 2
Indicates the instantaneous current consumption.
The meter_current2
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Device Configuration
The following table provides a summary of the 9 configuration parameters available in the TD13010. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | D1 automatically turn off | Time in second that the O2 will turn off automatically. |
2 | D2 automatically turn off | 0 : Disable (Default)1~32767: Time in second that the O2 will turn off automatically. Size: 2 Byte, Default Value: 0 |
3 | Switch Type | Switch Type |
4 | Reload power status | Reload power status |
5 | Power reporting on power change | 0 : Disabled1~100 : 1 % ~ 100 %. (Default = 10%) Size: 1 Byte, Default Value: 10 |
6 | Watts auto-report period | 0 : Disabled60~32767Seconds. (Default = 300 Seconds) Size: 2 Byte, Default Value: 300 |
7 | KWH auto-report period | 0 : DisabledSet time interval of reporting KWH (60 ~32767) in seconds. Size: 2 Byte, Default Value: 3600 |
8 | D1 automatically turn on | 0 : Disable (Default)1~32767 : Time in second that the O2 will turn on automatically. Size: 2 Byte, Default Value: 0 |
9 | D2 automatically turn on | 0 : Disable (Default)1~32767: Time in second that the O2 will turn on automatically. Size: 2 Byte, Default Value: 0 |
Parameter 1: D1 automatically turn off
Time in second that the O2 will turn off automatically. Time in second that the O2 will turn off automatically.
0 : Disable (Default)
1~32767 :seconds Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_1_2
and is of type INTEGER
.
Parameter 2: D2 automatically turn off
0 : Disable (Default)1~32767: Time in second that the O2 will turn off automatically. Size: 2 Byte, Default Value: 0
Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Parameter 3: Switch Type
Switch Type 0 : Toggle switches (Default)
1 : Toggle switches with memory
2 : Momentary switch
Size: 1 Byte, Default Value: 0 The following option values may be configured, in addition to values in the range 0 to 2 -:
Value | Description |
---|---|
0 | Toggle switches |
1 | Toggle switches with memory |
2 | Momentary switch |
The manufacturer defined default value is 0
(Toggle switches).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: Reload power status
Reload power status 0 : device does not memorize its status at power cut. Load is disconnected
1 : device memorizes its status at the power cut.Load will be set to the status from before power cut.
Size: 1 Byte, Default Value: 0 The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | Always Off |
1 | memorizes last status |
The manufacturer defined default value is 0
(Always Off).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 5: Power reporting on power change
0 : Disabled1~100 : 1 % ~ 100 %. (Default = 10%) Size: 1 Byte, Default Value: 10
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter 6: Watts auto-report period
0 : Disabled60~32767Seconds. (Default = 300 Seconds) Size: 2 Byte, Default Value: 300
Values in the range 60 to 32767 may be set.
The manufacturer defined default value is 300
.
This parameter has the configuration ID config_6_2
and is of type INTEGER
.
Parameter 7: KWH auto-report period
0 : DisabledSet time interval of reporting KWH (60 ~32767) in seconds. Size: 2 Byte, Default Value: 3600
Values in the range 30 to 32767 may be set.
The manufacturer defined default value is 3600
.
This parameter has the configuration ID config_7_2
and is of type INTEGER
.
Parameter 8: D1 automatically turn on
0 : Disable (Default)1~32767 : Time in second that the O2 will turn on automatically. Size: 2 Byte, Default Value: 0
Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_8_2
and is of type INTEGER
.
Parameter 9: D2 automatically turn on
0 : Disable (Default)1~32767: Time in second that the O2 will turn on automatically. Size: 2 Byte, Default Value: 0
Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_9_2
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The TD13010 supports 5 association groups.
Group 1: Group 1
Lifeline Reports the device status and allows for assigning single device only (main controller by default).
Association group 1 supports 5 nodes.
Group 2: Group 2
alarm EP 1It is assigned to switch connected to the S1 terminal (uses Notification command class)
Association group 2 supports 5 nodes.
Group 3: Group 3
Switch 1It is assigned to switch connected to the S1 terminal (uses Basic command class)
Association group 3 supports 5 nodes.
Group 4: Group 4
alarm EP 2It is assigned to switch connected to the S1 terminal (uses Notification command class)
Association group 4 supports 5 nodes.
Group 5: Group 5
Switch 2It is assigned to switch connected to the S1 terminal (uses Basic command class)
Association group 5 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_TRANSPORT_SERVICE_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_SUPERVISION_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V8 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | |
COMMAND_CLASS_SECURITY_V1 | |
COMMAND_CLASS_SECURITY_2_V1 |
Endpoint 1
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | |
COMMAND_CLASS_SECURITY_V1 |
Endpoint 2
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | |
COMMAND_CLASS_SECURITY_V1 |