openhab-docs/_addons_bindings/zwave/doc/goodway/TD13010_0_0.md

15 KiB

layout title
documentation TD13010 - ZWave

{% include base.html %}

TD13010 In wall Power Monitor Switch

This describes the Z-Wave device TD13010, manufactured by Good Way Technology Co., Ltd with the thing type UID of goodway_TD13010_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

TD13010 product image

The TD13010 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

This In-wall Power Monitor Switch is a transceiver which is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Mini-size

Inclusion Information

Include/Exclude Button - Inclusion/exclusion, press 3 times in 2 seconds

Exclusion Information

Include/Exclude Button - Inclusion/exclusion, press 3 times in 2 seconds

General Usage Information

Channels

The following table summarises the channels available for the TD13010 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Alarm (power) alarm_power alarm_power Energy Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Electric meter (volts) 1 meter_voltage1 meter_voltage Energy Number
Electric meter (amps) 1 meter_current1 meter_current Energy Number
Switch 2 switch_binary2 switch_binary Switch Switch
Electric meter (watts) 2 meter_watts2 meter_watts Energy Number
Electric meter (kWh) 2 meter_kwh2 meter_kwh Energy Number
Electric meter (volts) 2 meter_voltage2 meter_voltage Energy Number
Electric meter (amps) 2 meter_current2 meter_current Energy Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Switch 1

Switch the power on and off.

The switch_binary1 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (watts) 1

Indicates the instantaneous power consumption.

The meter_watts1 channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 1

Indicates the energy consumption (kWh).

The meter_kwh1 channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts) 1

Indicates the instantaneous voltage.

The meter_voltage1 channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps) 1

Indicates the instantaneous current consumption.

The meter_current1 channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Switch 2

Switch the power on and off.

The switch_binary2 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (watts) 2

Indicates the instantaneous power consumption.

The meter_watts2 channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 2

Indicates the energy consumption (kWh).

The meter_kwh2 channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts) 2

Indicates the instantaneous voltage.

The meter_voltage2 channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps) 2

Indicates the instantaneous current consumption.

The meter_current2 channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the TD13010. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 D1 automatically turn off Time in second that the O2 will turn off automatically.
2 D2 automatically turn off 0 : Disable (Default)1~32767: Time in second that the O2 will turn off automatically. Size: 2 Byte, Default Value: 0
3 Switch Type Switch Type
4 Reload power status Reload power status
5 Power reporting on power change 0 : Disabled1~100 : 1 % ~ 100 %. (Default = 10%) Size: 1 Byte, Default Value: 10
6 Watts auto-report period 0 : Disabled60~32767Seconds. (Default = 300 Seconds) Size: 2 Byte, Default Value: 300
7 KWH auto-report period 0 : DisabledSet time interval of reporting KWH (60 ~32767) in seconds. Size: 2 Byte, Default Value: 3600
8 D1 automatically turn on 0 : Disable (Default)1~32767 : Time in second that the O2 will turn on automatically. Size: 2 Byte, Default Value: 0
9 D2 automatically turn on 0 : Disable (Default)1~32767: Time in second that the O2 will turn on automatically. Size: 2 Byte, Default Value: 0

Parameter 1: D1 automatically turn off

Time in second that the O2 will turn off automatically. Time in second that the O2 will turn off automatically. 

0 : Disable (Default)

1~32767 :seconds Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Parameter 2: D2 automatically turn off

0 : Disable (Default)1~32767: Time in second that the O2 will turn off automatically. Size: 2 Byte, Default Value: 0

Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Switch Type

Switch Type 0 : Toggle switches (Default)

1 : Toggle switches with memory

2 : Momentary switch 

Size: 1 Byte, Default Value: 0 The following option values may be configured, in addition to values in the range 0 to 2 -:

Value Description
0 Toggle switches
1 Toggle switches with memory
2 Momentary switch

The manufacturer defined default value is 0 (Toggle switches).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Reload power status

Reload power status 0 : device does not memorize its status at power cut. Load is disconnected 

1 : device memorizes its status at the power cut.Load will be set to the status from before power cut. 

Size: 1 Byte, Default Value: 0 The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Always Off
1 memorizes last status

The manufacturer defined default value is 0 (Always Off).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Power reporting on power change

0 : Disabled1~100 : 1 % ~ 100 %. (Default = 10%) Size: 1 Byte, Default Value: 10

Values in the range 0 to 100 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Watts auto-report period

0 : Disabled60~32767Seconds. (Default = 300 Seconds) Size: 2 Byte, Default Value: 300

Values in the range 60 to 32767 may be set.

The manufacturer defined default value is 300.

This parameter has the configuration ID config_6_2 and is of type INTEGER.

Parameter 7: KWH auto-report period

0 : DisabledSet time interval of reporting KWH (60 ~32767) in seconds. Size: 2 Byte, Default Value: 3600

Values in the range 30 to 32767 may be set.

The manufacturer defined default value is 3600.

This parameter has the configuration ID config_7_2 and is of type INTEGER.

Parameter 8: D1 automatically turn on

0 : Disable (Default)1~32767 : Time in second that the O2 will turn on automatically. Size: 2 Byte, Default Value: 0

Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_8_2 and is of type INTEGER.

Parameter 9: D2 automatically turn on

0 : Disable (Default)1~32767: Time in second that the O2 will turn on automatically. Size: 2 Byte, Default Value: 0

Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_9_2 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The TD13010 supports 5 association groups.

Group 1: Group 1

Lifeline Reports the device status and allows for assigning single device only (main controller by default).

Association group 1 supports 5 nodes.

Group 2: Group 2

alarm EP 1It is assigned to switch connected to the S1 terminal (uses Notification command class)

Association group 2 supports 5 nodes.

Group 3: Group 3

Switch 1It is assigned to switch connected to the S1 terminal (uses Basic command class)

Association group 3 supports 5 nodes.

Group 4: Group 4

alarm EP 2It is assigned to switch connected to the S1 terminal (uses Notification command class)

Association group 4 supports 5 nodes.

Group 5: Group 5

Switch 2It is assigned to switch connected to the S1 terminal (uses Basic command class)

Association group 5 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_TRANSPORT_SERVICE_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_SECURITY_2_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.