FGS221 Double Relay Switch 2x1.5kW
This describes the Z-Wave device FGS221, manufactured by Fibargroup with the thing type UID of fibaro_fgs221_01_009
.
This version of the device is limited to firmware versions 1.9 to 1.11
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The FGS221 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
Remotely Controlled Relay Switch of Fibaro System is designed to operate in a wall switch box or in locations where the control of an electric device (up to 3kW) is needed.
It is also possible to send a signal to any system that is to be integrated with Fibaro system.
Inclusion Information
Add Fibaro Switch to the network by pushing three times key no. 1 or push-button B located inside the housing of the device. For toggle switch perform 3 position changes.
Exclusion Information
Remove Fibaro Switch from the network by pushing three times key no. 1 or push-button B located inside the housing of the device. For toggle switch perform 3 position changes.
Channels
The following table summarises the channels available for the FGS221 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Switch 1 | switch_binary1 | switch_binary | Switch | Switch |
Switch 2 | switch_binary2 | switch_binary | Switch | Switch |
Switch
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Switch 1
Switch the power on and off.
The switch_binary1
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Switch 2
Switch the power on and off.
The switch_binary2
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Device Configuration
The following table provides a summary of the 19 configuration parameters available in the FGS221. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Enable/Disable ALL ON/OFF | Activate/Deactive ALL ON/OFF |
3 | Enable/Disable Manual Override | Enable / Disable manual override for relay auto off |
4 | Relay 1: OFF-delay time | Automatic turning off relay 1 after set time in milliseconds, 0 to disable |
5 | Relay 2: OFF-delay time | Automatic turning off relay 2 after set time in milliseconds, 0 to disable |
6 | Separation of association sending (key 1) | Activate/Deactivate association sending for group 1 - Also see param #16 |
7 | Control key #2 behaviour | Map status to devices in group 2. |
13 | Inputs behaviour | In case of bi-stable switches, define their behaviour (toggle or follow) |
14 | Inputs Button/Switch configuration | Binary inputs type configuration |
15 | Dimmer/Roller shutter control | Enable/Disable operation of dimmer associated to group 1. |
16 | Saving state before power failure | Saving state before power failure |
30 | Relay 1: Response to General Alarm | |
31 | Relay 1: Response to Water Flood Alarm | |
32 | Relay 1: Response to Smoke, CO, CO2 Alarm | |
33 | Relay 1: Response to Temperature Alarm | |
39 | ALARM FLASHING alarm time | Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame |
40 | Relay 2: Response to General Alarm | |
41 | Relay 2: Response to Water Flood Alarm | |
42 | Relay 2: Response to Smoke, CO, CO2 Alarm | |
43 | Relay 2: Response to Temperature Alarm | |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 1: Enable/Disable ALL ON/OFF
Activate/Deactive ALL ON/OFF
The following option values may be configured -:
Value | Description |
---|---|
-1 | ALL ON active / ALL OFF active |
0 | ALL ON disabled/ ALL OFF disabled |
1 | ALL ON disabled/ ALL OFF active |
2 | ALL ON active / ALL OFF disabled |
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 3: Enable/Disable Manual Override
Enable / Disable manual override for relay auto off
The following option values may be configured -:
Value | Description |
---|---|
0 | Manual Override Disabled |
1 | Manual Override Enabled |
The manufacturer defined default value is 0
(Manual Override Disabled).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: Relay 1: OFF-delay time
Automatic turning off relay 1 after set time in milliseconds, 0 to disable
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_4_2
and is of type INTEGER
.
Parameter 5: Relay 2: OFF-delay time
Automatic turning off relay 2 after set time in milliseconds, 0 to disable
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_5_2
and is of type INTEGER
.
Parameter 6: Separation of association sending (key 1)
Activate/Deactivate association sending for group 1 - Also see param #16
The following option values may be configured -:
Value | Description |
---|---|
0 | Map status to devices in group 1 |
1 | Map OFF status to group 1-last state |
2 | Map OFF status to group 1-full brightness |
The manufacturer defined default value is 0
(Map status to devices in group 1).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Parameter 7: Control key #2 behaviour
Map status to devices in group 2. Commands are sent when device is turned off. Enabling device does not send control commands. Double-clicking key sends 'turn on' command, dimmers memorize the last saved state (e.g. 50% brightness). The following option values may be configured -:
Value | Description |
---|---|
0 | Device status is not checked |
1 | Device status is checked |
The manufacturer defined default value is 1
(Device status is checked).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Parameter 13: Inputs behaviour
In case of bi-stable switches, define their behaviour (toggle or follow)
The following option values may be configured -:
Value | Description |
---|---|
0 | Toggle |
1 | Follow switch contact (closed=ON, open=OFF) |
The manufacturer defined default value is 0
(Toggle).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Parameter 14: Inputs Button/Switch configuration
Binary inputs type configuration
The following option values may be configured -:
Value | Description |
---|---|
0 | Mono-stable input (button) |
1 | Bi-stable input (switch) |
The manufacturer defined default value is 1
(Bi-stable input (switch)).
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
Parameter 15: Dimmer/Roller shutter control
Enable/Disable operation of dimmer associated to group 1. Enable/Disable operation of dimmer or roller shutter devices associated to group 1. Available only when using mono-stable inputs (buttons) - Hold button 1 or double-tap for operation The following option values may be configured -:
Value | Description |
---|---|
0 | Disable Dimmer/Roller shutter control |
1 | Enable Dimmer/Roller shutter control |
The manufacturer defined default value is 0
(Disable Dimmer/Roller shutter control).
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
Parameter 16: Saving state before power failure
Saving state before power failure
The following option values may be configured -:
Value | Description |
---|---|
0 | State NOT saved at power failure |
1 | State saved at power failure |
The manufacturer defined default value is 1
(State saved at power failure).
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
Parameter 30: Relay 1: Response to General Alarm
The following option values may be configured -:
Value | Description |
---|---|
0 | DEACTIVATION - no response to alarm frames |
1 | Alarm Relay ON |
2 | Alarm Relay OFF |
3 | Alarm Flashing |
The manufacturer defined default value is 3
(Alarm Flashing).
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
Parameter 31: Relay 1: Response to Water Flood Alarm
The following option values may be configured -:
Value | Description |
---|---|
0 | DEACTIVATION - no response to alarm frames |
1 | Alarm Relay ON |
2 | Alarm Relay OFF |
3 | Alarm Flashing |
The manufacturer defined default value is 2
(Alarm Relay OFF).
This parameter has the configuration ID config_31_1
and is of type INTEGER
.
Parameter 32: Relay 1: Response to Smoke, CO, CO2 Alarm
The following option values may be configured -:
Value | Description |
---|---|
0 | DEACTIVATION - no response to alarm frames |
1 | Alarm Relay ON |
2 | Alarm Relay OFF |
3 | Alarm Flashing |
The manufacturer defined default value is 3
(Alarm Flashing).
This parameter has the configuration ID config_32_1
and is of type INTEGER
.
Parameter 33: Relay 1: Response to Temperature Alarm
The following option values may be configured -:
Value | Description |
---|---|
0 | DEACTIVATION - no response to alarm frames |
1 | Alarm Relay ON |
2 | Alarm Relay OFF |
3 | Alarm Flashing |
The manufacturer defined default value is 1
(Alarm Relay ON).
This parameter has the configuration ID config_33_1
and is of type INTEGER
.
Parameter 39: ALARM FLASHING alarm time
Amount of time (ms) the device keeps on flashing after receipt of Alarm Frame
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_39_2
and is of type INTEGER
.
Parameter 40: Relay 2: Response to General Alarm
The following option values may be configured -:
Value | Description |
---|---|
0 | DEACTIVATION - no response to alarm frames |
1 | Alarm Relay ON |
2 | Alarm Relay OFF |
3 | Alarm Flashing |
The manufacturer defined default value is 3
(Alarm Flashing).
This parameter has the configuration ID config_40_1
and is of type INTEGER
.
Parameter 41: Relay 2: Response to Water Flood Alarm
The following option values may be configured -:
Value | Description |
---|---|
0 | DEACTIVATION - no response to alarm frames |
1 | Alarm Relay ON |
2 | Alarm Relay OFF |
3 | Alarm Flashing |
The manufacturer defined default value is 2
(Alarm Relay OFF).
This parameter has the configuration ID config_41_1
and is of type INTEGER
.
Parameter 42: Relay 2: Response to Smoke, CO, CO2 Alarm
The following option values may be configured -:
Value | Description |
---|---|
0 | DEACTIVATION - no response to alarm frames |
1 | Alarm Relay ON |
2 | Alarm Relay OFF |
3 | Alarm Flashing |
The manufacturer defined default value is 3
(Alarm Flashing).
This parameter has the configuration ID config_42_1
and is of type INTEGER
.
Parameter 43: Relay 2: Response to Temperature Alarm
The following option values may be configured -:
Value | Description |
---|---|
0 | DEACTIVATION - no response to alarm frames |
1 | Alarm Relay ON |
2 | Alarm Relay OFF |
3 | Alarm Flashing |
The manufacturer defined default value is 1
(Alarm Relay ON).
This parameter has the configuration ID config_43_1
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The FGS221 supports 3 association groups.
Group 1: Switch 1
Association group 1 supports 16 nodes.
Group 2: Switch 2
Association group 2 supports 16 nodes.
Group 3: Controller Updates
Association group 3 supports 1 node.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1 |
Endpoint 1
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
Endpoint 2
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
Documentation Links