ECO-DIM.06 or ECO-DIM.07 Smart Dimmer LED
This describes the Z-Wave device ECO-DIM.06 or ECO-DIM.07, manufactured by EcoBright with the thing type UID of ecobright_ecodim07_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ECO-DIM.06 or ECO-DIM.07 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
ECO-DIM.06: Plug-in dimmer Z-Wave 0-100W
Plug the Z-Wave plug-in dimmer into the socket and insert the euro plug of your LED lamp into this plug-in dimmer. You can then dim the LED lamps and press on/off with the push/turn button. Unique is the MIN adjustment option, with which you can set the minimum light level yourself!
ECO-DIM.07: Smart LED dimmer Z-Wave 0-200W
Remotely controlled multi level push / turn dimmer that can be controlled through Z-Wave and Zigbee (by setting a hardware switch). The dimmer is suitable for 0-200W LED lights where the MIN and MAX values can be set with hardware dials. The dimmer can be installed in a 2 wire setup (no N-wire required) and has a soft start system.
Inclusion Information
ECO-DIM.06:
- Step 1. Remove the device from a previous Z-Wave network if it has already been added to one, otherwise pairing mode will be fail.
- Step 2. From your Z-Wave Controller interface, choose to add lighting and enter the pairing mode
- Step 3. Double Press the reset button.
- Step 4. The indicator will start blinking blue and will stay solid for 10s when pairing succeeds. Timeout 15mins.
ECO-DIM.07:
Make sure the right switch is set to Z-Wave. Power on the dimmer, press and hold the reset button for over 4 seconds.
Exclusion Information
ECO-DIM.06:
Method 1. From your Z-Wave hub interface, choose to delete or reset the device as instructed.
Method 2. Remove from the Device, see below instructions.
- Step 1. Press the reset button for 3 times.
- Step 2. The indicator will start blinking purple and will stay solid for 10s when removing is completed. Timeout 3mins.
ECO-DIM.07:
There are two exclusion methods:
- Exclusion from the primary controller / gateway:
Twice press the reset button, the dimmer will be set to exclusion mode, waiting to be excluded.
- Factory reset the dimmer (forcing it to be excluded from a network):
Press and hold down the reset button for over 4 seconds, the dimmer will be reset to factory defaults after the BLUE LED indicator blinks.
General Usage Information
To make the dimmer work optimally you can adjust the lamps optimally to the dimmer with the MIN MAX adjustment.
Set MIN
Switch on the lights with the push / turn button. When the lights are on, put a screwdriver in the MIN and turn to the left. When the light becomes unstable turn a little further to the right so that the light remains stable.
Set MAX
Switch on the lights with the push / turn button. When the lights are on put a screwdriver in the MAX and turn to the right. When the light becomes unstable turn a little further to the left so that the light remains stable.
Channels
The following table summarises the channels available for the ECO-DIM.06 or ECO-DIM.07 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Reset Meter | meter_reset | meter_reset | Energy | Switch |
Dimmer
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Electric meter (watts)
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (kWh)
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Reset Meter
Reset the meter.
The meter_reset
channel is of type meter_reset
and supports the Switch
item and is in the Energy
category.
Device Configuration
The following table provides a summary of the 2 configuration parameters available in the ECO-DIM.06 or ECO-DIM.07. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | State after power restored | Switch state after power failure |
2 | Notify load status change | Send notification to associated device when status is changed. |
Parameter 1: State after power restored
Switch state after power failure State after power restored. The state the switch should return to once power is restored after power failure. The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
1 | On |
2 | Return to state after power outage |
The manufacturer defined default value is 1
(ON).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Notify load status change
Send notification to associated device when status is changed. Notification when load status changes. The dimmer will send notification to associated device (group lifeline) when the status of the dimmer load is changed. The following option values may be configured -:
Value | Description |
---|---|
0 | The function is disabled |
1 | Send switch multilevel report |
2 | When load status has not changed |
The manufacturer defined default value is 1
(Send switch multilevel report).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ECO-DIM.06 or ECO-DIM.07 supports 1 association group.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 1 node.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | Linked to BASIC |
COMMAND_CLASS_METER_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_SECURITY_V1 |