DSC24 Smart Energy Switch G2
This describes the Z-Wave device DSC24, manufactured by AEON Labs with the thing type UID of aeon_dsc24_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The DSC24 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
There are appliances that we turn on and off in our homes each day. And, despite the fact that it'd save us money, there are those that we could turn off if only it was easier. Aeotec by Aeon Labs’ Smart Switch (2nd Edition) and Switch (2nd Edition) package convenience, control and money saving considerations into one, small, plug-in tool. A tool that can be programmed, scheduled, controlled and communicated with from anywhere in the wor
Inclusion Information
- Press the Action Button on your switch.
- If your switch has been successfully linked to your network, its LED will no longer blink. If the linking was unsuccessful the LED will continue to blink.
Exclusion Information
- Press the Action Button on your switch.
- If your switch has been successfully removed from your network, its LED will blink. If the removal was unsuccessful its LED will not blink
Channels
The following table summarises the channels available for the DSC24 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Scene Number | scene_number | scene_number | Number | |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Reset Meter | meter_reset | meter_reset | Energy | Switch |
Switch
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Scene Number
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
Electric meter (kWh)
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (watts)
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (amps)
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (volts)
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Reset Meter
Reset the meter.
The meter_reset
channel is of type meter_reset
and supports the Switch
item and is in the Energy
category.
Device Configuration
The following table provides a summary of the 16 configuration parameters available in the DSC24. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Multilevel Sensor Report Content | |
2 | Make SES blink | |
80 | Automatic Notifications | Enables automatic notifications to associated devices |
90 | Enable Parameter 91 | Enables/disables parameter 91 and 92 below |
91 | Minimum change in wattage | Minimum change in wattage for a REPORT to be sent. |
92 | Minimum change in wattage % | Minimum change in wattage percent for a REPORT to be sent. |
100 | Set 100 to 103 to default | |
101 | Group 1 report | |
102 | Group 2 report | |
103 | Group 3 report | |
110 | Set 111 to 113 to default | |
111 | Interval group 1 | The time interval of sending Report group 1 |
112 | Interval group 2 | The time interval of sending Report group 2 |
113 | Interval group 3 | The time interval of sending Report group 3 |
254 | Device Tag | |
255 | Device Reset | |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 1: Multilevel Sensor Report Content
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Make SES blink
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Parameter 80: Automatic Notifications
Enables automatic notifications to associated devices Enables automatic notifications to associated devices whenever there is a state change The following option values may be configured -:
Value | Description |
---|---|
0 | Nothing |
1 | Hail |
2 | Basic CC Report |
The manufacturer defined default value is 0
(Nothing).
This parameter has the configuration ID config_80_1
and is of type INTEGER
.
Parameter 90: Enable Parameter 91
Enables/disables parameter 91 and 92 below
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_90_1
and is of type INTEGER
.
Parameter 91: Minimum change in wattage
Minimum change in wattage for a REPORT to be sent.
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_91_2
and is of type INTEGER
.
Parameter 92: Minimum change in wattage %
Minimum change in wattage percent for a REPORT to be sent.
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_92_1
and is of type INTEGER
.
Parameter 100: Set 100 to 103 to default
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_100_1
and is of type INTEGER
.
Parameter 101: Group 1 report
The following option values may be configured -:
Value | Description |
---|---|
2 | Multisensor Report |
4 | Meter Report (Watts) |
8 | Meter Report (kWh) |
The manufacturer defined default value is 8
(Meter Report (kWh)).
This parameter has the configuration ID config_101_4
and is of type INTEGER
.
Parameter 102: Group 2 report
The following option values may be configured -:
Value | Description |
---|---|
2 | Multisensor Report |
4 | Meter Report (Watts) |
8 | Meter Report (kWh) |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_102_4
and is of type INTEGER
.
Parameter 103: Group 3 report
The following option values may be configured -:
Value | Description |
---|---|
2 | Multisensor Report |
4 | Meter Report (Watts) |
8 | Meter Report (kWh) |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_103_4
and is of type INTEGER
.
Parameter 110: Set 111 to 113 to default
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_110_1
and is of type INTEGER
.
Parameter 111: Interval group 1
The time interval of sending Report group 1
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_111_4
and is of type INTEGER
.
Parameter 112: Interval group 2
The time interval of sending Report group 2
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_112_4
and is of type INTEGER
.
Parameter 113: Interval group 3
The time interval of sending Report group 3
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_113_4
and is of type INTEGER
.
Parameter 254: Device Tag
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_254_2
and is of type INTEGER
.
Parameter 255: Device Reset
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_255_1
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The DSC24 supports 2 association groups.
Group 1: Status Reports
Association group 1 supports 5 nodes.
Group 2: Send Reports on blind state change
Send Reports on blind state change
Association group 2 supports 10 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_CRC_16_ENCAP_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |