8.5 KiB
layout | title |
---|---|
documentation | ZME_TIO_4S - ZWave |
{% include base.html %}
ZME_TIO_4S TION 4S Ventilator
This describes the Z-Wave device ZME_TIO_4S, manufactured by Z-Wave.Me with the thing type UID of zwaveme_zmetio4s_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The ZME_TIO_4S supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
Compact ventilation system, developed by tion.ru
Inclusion Information
Turn off device until yellow light shows, press and keep power button until blue color starts blinking
Exclusion Information
Turn off device until yellow light shows, press and keep power button until blue color starts blinking
General Usage Information
Channels
The following table summarises the channels available for the ZME_TIO_4S -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Power switch | switch_binary | switch_binary | Switch | Switch |
Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Thermostat mode 1 | thermostat_mode1 | thermostat_mode | Temperature | Number |
Setpoint (heating) 1 | thermostat_setpoint1 | thermostat_setpoint | Heating | Number:Temperature |
Power switch | switch_binary2 | switch_binary | Switch | Switch |
Air Type | switch_binary3 | switch_binary | Switch | Switch |
FanSpeed | switch_dimmer4 | switch_dimmer | DimmableLight | Dimmer |
sensor (InflowTemperature) | sensor_temperature5 | sensor_temperature | Temperature | Number:Temperature |
sensor (Outflow Temperature) | sensor_temperature6 | sensor_temperature | Temperature | Number:Temperature |
Power switch
on/off device switch
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Thermostat mode
Heater mode of external air
Sets the thermostat.
The thermostat_mode
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Setpoint (heating)
Air heating temperature
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Thermostat mode 1
Sets the thermostat.
The thermostat_mode1
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Setpoint (heating) 1
Sets the thermostat setpoint.
The thermostat_setpoint1
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Power switch
Switch the power on and off.
The switch_binary2
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Air Type
off - inflow
on - room
Switch the power on and off.
The switch_binary3
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
FanSpeed
Fan speed, step 16
1 - 16
2 - 32
3 - 48
4 - 64
5 - 80
6 - 96
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer4
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
sensor (InflowTemperature)
Indicates the current temperature.
The sensor_temperature5
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
sensor (Outflow Temperature)
Indicates the current temperature.
The sensor_temperature6
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Device Configuration
The following table provides a summary of the 2 configuration parameters available in the ZME_TIO_4S. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
20 | AllowsFirmwareUpdates | Firmware updates |
66 | Fibaro | Fibaro controller compatibility |
Parameter 20: AllowsFirmwareUpdates
Firmware updates Defines if firmware update allowed Values in the range 0 to 0 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_20_4
and is of type INTEGER
.
Parameter 66: Fibaro
Fibaro controller compatibility
The following option values may be configured -:
Value | Description |
---|---|
0 | fibaro |
1 | non fibaro |
The manufacturer defined default value is 1
(non fibaro).
This parameter has the configuration ID config_66_2
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZME_TIO_4S supports 1 association group.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Lifeline Lifeline group
Association group 1 supports 10 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_V4 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V3 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | |
COMMAND_CLASS_SECURITY_V1 |
Endpoint 1
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 |
Endpoint 2
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 |
Endpoint 3
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 |
Endpoint 4
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 |
Endpoint 5
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V7 |
Endpoint 6
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V7 |
Documentation Links