ZD2102-5 Door Window Sensor
This describes the Z-Wave device ZD2102-5, manufactured by Vision Security with the thing type UID of vision_zd2102plus_00_000
.
The device is in the category of Door, defining Door sensors.
The ZD2102-5 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZD2102-5 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
Overview
Wireless Door/ Window Sensor
Inclusion Information
Press the program switch of ZD2102 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion; otherwise, ZD2102 will go to sleep after 15 seconds.
Exclusion Information
Press the program switch of ZD2102 for 1 second at least to be excluded.
Wakeup Information
The ZD2102-5 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
It will be triggering after opening the rear cover, also the red LED will keep on lasting 10 seconds and ZD2102 will send “Wake Up Notification” after 10 seconds. If ZD2102 received “Wake Up No More Information” command then the red LED will go off or it will wait 10 seconds then go off. It will proceed all the commands after sending the “Wake Up Notification”
Channels
The following table summarises the channels available for the ZD2102-5 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Door Sensor | sensor_door | sensor_door | Door | Contact |
Tamper Alarm | alarm_tamper | alarm_tamper | Switch | |
Battery | alarm_battery | alarm_battery | LowBattery | Switch |
Battery Level | battery-level | system.battery_level | Battery | Number |
Door Sensor
Indicates if the door/window is open or closed.
The sensor_door
channel is of type sensor_door
and supports the Contact
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Contact
item type -:
Value | Label |
---|---|
OPEN | Open |
CLOSED | Closed |
Tamper Alarm
Indicates if the tamper alarm is triggered.
The alarm_tamper
channel is of type alarm_tamper
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Battery
Indicates if the low battery alarm is triggered.
The alarm_battery
channel is of type alarm_battery
and supports the Switch
item and is in the LowBattery
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
Device Configuration
The following table provides a summary of the 1 configuration parameters available in the ZD2102-5. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | External switch | Determines if the external switch can be used. |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
Parameter 1: External switch
Determines if the external switch can be used.
The following option values may be configured, in addition to values in the range 0 to 255 -:
Value | Description |
---|---|
0 | Disable (default) |
255 | Enable |
The manufacturer defined default value is 0
(Disable (default)).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Wakeup Interval
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
Wakeup Node
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZD2102-5 supports 1 association group.
Group 1: Control Command
Association group 1 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V4 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_SECURITY_V1 |