openhab-docs/_addons_bindings/zwave/doc/utec/uboltpro_0_0.md

6.7 KiB

layout title
documentation U-Bolt Pro Z-wave - ZWave

{% include base.html %}

U-Bolt Pro Z-wave Smart Lock

This describes the Z-Wave device U-Bolt Pro Z-wave, manufactured by U-Tec Group with the thing type UID of utec_uboltpro_00_000.

The device is in the category of Battery, defining Batteries, Energy Storages.

U-Bolt Pro Z-wave product image

The U-Bolt Pro Z-wave supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

Smart Lock from U-tec Ultraloq.  Z-wave support includes Lock, Unlock, and setting user access codes. 

Inclusion Information

To include this lock, you must first connect to it with the phone app.
Then, in the settings for the lock, click the "Z-wave Control" option. 
Select "Add to Z-wave Hub"
Select "Start Inclusion"

Then, start scanning for new Z-wave devices in openHAB.

If using an S2 Z-wave controller, you will need to enter the 4-digit code provided by the u-tec app. 

Exclusion Information

Connect to the lock with the phone app.

Then, in the settings for the lock, click the "Z-wave Control" option.

Select "Remove from Z-wave Hub"

Select "Start the Exclusion"

Then, initiate exclusion in openHAB.

General Usage Information

Channels

The following table summarises the channels available for the U-Bolt Pro Z-wave -:

Channel Name Channel ID Channel Type Category Item Type
Door Lock lock_door lock_door Door Switch
User Code notification_access_control notification_access_control Number
Battery Level battery-level system.battery_level Battery Number

Door Lock

Lock and unlock the door.

The lock_door channel is of type lock_door and supports the Switch item and is in the Door category. The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Locked
OFF Unlocked

User Code

Access Control.

The notification_access_control channel is of type notification_access_control and supports the Number item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Number item type -:

Value Label
0 Previous Events cleared
1 Manual Lock Operation
2 Manual Unlock Operation
3 RF Lock Operation
4 RF Unlock Operation
5 Keypad Lock Operation
6 Keypad Unlock Operation
7 Manual Not Fully Locked Operation
8 RF Not Fully Locked Operation
9 Auto Lock Locked Operation
10 Auto Lock Not Fully Operation
11 LockJammed
12 All user codes deleted
13 Single user code deleted
14 New user code added
15 New user code not added due to duplicate code
16 Keypad temporary disabled
17 Keypad busy
18 New Program code Entered- Unique code for lock configuration
19 Manually Enter user Access code exceeds code limit
20 Unlock by RF with invalid user code
21 Locked by RF with invalid user code
22 Window/Door is open
23 Window/Door is closed
64 Barrier performing initialization process
65 Barrier operation (Open / Close) force has been exceeded
66 Barrier motor has exceeded manufacturer's operational time limit
67 Barrier operation has exceeded physical mechanical limits
68 Barrier unable to perform requested operation due to UL requirements
69 Barrier Unattended operation has been disabled per UL requirements
70 Barrier failed to perform Requested operation, device malfunction
71 Barrier Vacation Mode
72 Barrier Safety Beam Obstacle
73 Barrier Sensor Not Detected / Supervisory Error
74 Barrier Sensor Low Battery Warning
75 Barrier detected short in WallStation wires
76 Barrier associated with non-Z-wave remote control

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The U-Bolt Pro Z-wave supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_TRANSPORT_SERVICE_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_DOOR_LOCK_V1
COMMAND_CLASS_USER_CODE_V1
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_INDICATOR_V3
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_SECURITY_2_V1

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.