6.7 KiB
layout | title |
---|---|
documentation | U-Bolt Pro Z-wave - ZWave |
{% include base.html %}
U-Bolt Pro Z-wave Smart Lock
This describes the Z-Wave device U-Bolt Pro Z-wave, manufactured by U-Tec Group with the thing type UID of utec_uboltpro_00_000
.
The device is in the category of Battery, defining Batteries, Energy Storages.
The U-Bolt Pro Z-wave supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
Overview
Smart Lock from U-tec Ultraloq. Z-wave support includes Lock, Unlock, and setting user access codes.
Inclusion Information
To include this lock, you must first connect to it with the phone app.
Then, in the settings for the lock, click the "Z-wave Control" option.
Select "Add to Z-wave Hub"
Select "Start Inclusion"
Then, start scanning for new Z-wave devices in openHAB.
If using an S2 Z-wave controller, you will need to enter the 4-digit code provided by the u-tec app.
Exclusion Information
Connect to the lock with the phone app.
Then, in the settings for the lock, click the "Z-wave Control" option.
Select "Remove from Z-wave Hub"
Select "Start the Exclusion"
Then, initiate exclusion in openHAB.
General Usage Information
Channels
The following table summarises the channels available for the U-Bolt Pro Z-wave -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Door Lock | lock_door | lock_door | Door | Switch |
User Code | notification_access_control | notification_access_control | Number | |
Battery Level | battery-level | system.battery_level | Battery | Number |
Door Lock
Lock and unlock the door.
The lock_door
channel is of type lock_door
and supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
User Code
Access Control.
The notification_access_control
channel is of type notification_access_control
and supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Previous Events cleared |
1 | Manual Lock Operation |
2 | Manual Unlock Operation |
3 | RF Lock Operation |
4 | RF Unlock Operation |
5 | Keypad Lock Operation |
6 | Keypad Unlock Operation |
7 | Manual Not Fully Locked Operation |
8 | RF Not Fully Locked Operation |
9 | Auto Lock Locked Operation |
10 | Auto Lock Not Fully Operation |
11 | LockJammed |
12 | All user codes deleted |
13 | Single user code deleted |
14 | New user code added |
15 | New user code not added due to duplicate code |
16 | Keypad temporary disabled |
17 | Keypad busy |
18 | New Program code Entered- Unique code for lock configuration |
19 | Manually Enter user Access code exceeds code limit |
20 | Unlock by RF with invalid user code |
21 | Locked by RF with invalid user code |
22 | Window/Door is open |
23 | Window/Door is closed |
64 | Barrier performing initialization process |
65 | Barrier operation (Open / Close) force has been exceeded |
66 | Barrier motor has exceeded manufacturer's operational time limit |
67 | Barrier operation has exceeded physical mechanical limits |
68 | Barrier unable to perform requested operation due to UL requirements |
69 | Barrier Unattended operation has been disabled per UL requirements |
70 | Barrier failed to perform Requested operation, device malfunction |
71 | Barrier Vacation Mode |
72 | Barrier Safety Beam Obstacle |
73 | Barrier Sensor Not Detected / Supervisory Error |
74 | Barrier Sensor Low Battery Warning |
75 | Barrier detected short in WallStation wires |
76 | Barrier associated with non-Z-wave remote control |
Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
Device Configuration
The device has no configuration parameters defined.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The U-Bolt Pro Z-wave supports 1 association group.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_TRANSPORT_SERVICE_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_DOOR_LOCK_V1 | |
COMMAND_CLASS_USER_CODE_V1 | |
COMMAND_CLASS_SUPERVISION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_INDICATOR_V3 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | |
COMMAND_CLASS_SECURITY_V1 | |
COMMAND_CLASS_SECURITY_2_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.