10001020-230 Simon iO dimmer switch
This describes the Z-Wave device 10001020-230, manufactured by SimonTech S.L.U with the thing type UID of simontech_10001020-230_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The 10001020-230 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
This product is standard, having dimensions of 85.5x83.5mm. Its type of emborning is by cut and can be installed both vertically and horizontally. It should be noted that the voltage capacity of this front kit for 1 element with 1 Simon iO switch will be 250V. This product of the Simon 100 series features activation using a push-button. The interval for the temperature of its proper operation will be from 5º C to 40º C and its storage temperature range is from -25º C to 50° C. For proper maintenance it is suggested to dampen a soft cloth slightly in soapy water, thus avoiding the use of abrasive cleaners that contain chlorine and may compromise the surface of the cloth.
Inclusion Information
When the pushbutton is released after a press of (2sec<T<20sec) the device will send a NIF to include the device to the Z-Wave network. Main LED will blink with 0,3 sec period.
Exclusion Information
When the pushbutton is released after a press of (2sec<T<20sec) the device will send a NIF to include the device to the Z-Wave network. Main LED will blink with 0,3 sec period.
General Usage Information
Channels
The following table summarises the channels available for the 10001020-230 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Dimmer
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Electric meter (watts)
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Device Configuration
The following table provides a summary of the 18 configuration parameters available in the 10001020-230. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Association LED | Association LED |
4 | Set time | Set time |
5 | Fade time | Fade time |
6 | Minimum dimming value | Minimum dimming value |
7 | Maximum dimming value | Maximum dimming value |
8 | Last on value | Last on value |
9 | Calibration | Calibration |
10 | Delay ON | Delay ON |
11 | Activation time | Activation time |
12 | Behavior of LED in repose | Behavior of LED in repose |
13 | Lock input | Lock input |
15 | Reset default | Reset default |
16 | Delay OFF | Delay OFF |
19 | Press action | Press action |
20 | Identify | Identify |
21 | State of charge | State of charge |
23 | Calibration required | Calibration required |
27 | Lock long press | Lock long press |
Parameter 1: Association LED
Association LED
The following option values may be configured -:
Value | Description |
---|---|
0 | Turns the main LED ON |
255 | Turns the main LED OFF |
The manufacturer defined default value is 0
(Turns the main LED ON).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 4: Set time
Set time 0x00 Instantly (default value) Disable timming
0x01-0x7F 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
0x80-0xFE 1 second (0x80) to 127 minutes (0xFE) in 1 minute resolution Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 5: Fade time
Fade time 0x00 Instantly (default value) Disable timming
0x01-0x7F 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
0x80-0xFE 1 second (0x80) to 127 minutes (0xFE) in 1 minute resolution Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter 6: Minimum dimming value
Minimum dimming value Stablishes the Max and Min percentages that can be reached. Once the devices gets a value through Z-Wave it Scales the value read according this Min and Max margins. Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Parameter 7: Maximum dimming value
Maximum dimming value Stablishes the Max and Min percentages that can be reached. Once the devices gets a value through Z-Wave it Scales the value read according this Min and Max margins. Values in the range 1 to 99 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Parameter 8: Last on value
Last on value Returns or sets the last non zero dimming value. In case of Set the device turns ON the load. Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Parameter 9: Calibration
Calibration
The following option values may be configured -:
Value | Description |
---|---|
1 | Smart Calibrate |
2 | Device is calibrated using Trailing Edge |
3 | Device is calibrated using Leading Edge |
The manufacturer defined default value is 1
(Smart Calibrate).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Parameter 10: Delay ON
Delay ON 0x00 Instantly (default value) Disable timming
0x01-0x7F 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
0x80-0xFE 1 second (0x80) to 127 minutes (0xFE) in 1 minute resolution Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Parameter 11: Activation time
Activation time 0x00 Instantly (default value) Disable timming
0x01-0x7F 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
0x80-0xFE 1 second (0x80) to 127 minutes (0xFE) in 1 minute resolution Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Parameter 12: Behavior of LED in repose
Behavior of LED in repose
The following option values may be configured -:
Value | Description |
---|---|
0 | LED OFF |
255 | Central LED on at 20% of maximum level |
The manufacturer defined default value is 0
(LED OFF).
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Parameter 13: Lock input
Lock input
The following option values may be configured -:
Value | Description |
---|---|
0 | Unlock the direct control of load |
255 | Lock the direct control of load |
The manufacturer defined default value is 0
(Unlock the direct control of load).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Parameter 15: Reset default
Reset default
The following option values may be configured -:
Value | Description |
---|---|
17170 | Soft reset |
39015 | Hard reset |
The manufacturer defined default value is 17170
(Soft reset).
This parameter has the configuration ID config_15_2_wo
and is of type INTEGER
.
This is a write only parameter.
Parameter 16: Delay OFF
Delay OFF 0x00 Instantly (default value) Disable timming
0x01-0x7F 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
0x80-0xFE 1 second (0x80) to 127 minutes (0xFE) in 1 minute resolution Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
Parameter 19: Press action
Press action
The following option values may be configured -:
Value | Description |
---|---|
0 | Device toggles the load |
1 | Device turns ON the load |
2 | Device turns OFF the load |
4 | Device turns the load ON and then OFF |
5 | Device toggles the load and dims |
The manufacturer defined default value is 5
(Device toggles the load and dims).
This parameter has the configuration ID config_19_1
and is of type INTEGER
.
Parameter 20: Identify
Identify The central LED blinks for 5 seconds in order to identify the device. The following option values may be configured -:
Value | Description |
---|---|
255 | The dimmer blinks |
The manufacturer defined default value is 255
(The dimmer blinks).
This parameter has the configuration ID config_20_1_wo
and is of type INTEGER
.
This is a write only parameter.
Parameter 21: State of charge
State of charge First byte
0x00 Load is OFF
0x01 Load is ON
Second byte 0x00 - 0x063 Last active dimming value Values in the range 0 to 65379 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_21_2
and is of type INTEGER
.
This is a read only parameter.
Parameter 23: Calibration required
Calibration required
The following option values may be configured -:
Value | Description |
---|---|
0 | Calibration not required |
255 | Calibration required |
The manufacturer defined default value is 0
(Calibration not required).
This parameter has the configuration ID config_23_1
and is of type INTEGER
.
This is a read only parameter.
Parameter 27: Lock long press
Lock long press
The following option values may be configured -:
Value | Description |
---|---|
0 | Default long press |
255 | Options |
The manufacturer defined default value is 0
(Default long press).
This parameter has the configuration ID config_27_1
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 10001020-230 supports 2 association groups.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. On/Off Report when load state is changed:
On -> CC Basic, Basic Report, Value 0x01 - 0x63 Report the dimming level
Off -> CC Basic, Basic Report, Value 0x00
Instant Power Consumption vary over 10% and is stable almost 2sec:
CC Meter, Meter Report, “Electric meter”, “Consumed”, “Watts”, Size 4, Precision 1, Value (W)
Calibration requirement change. (If device needs to be calibrated and is Added into a Z-Wave network, it will report after receive an Association Set of life line).
Calibration required -> CC Configuration, Configuration Report, Param 23, Value 0xFF
Calibration not required -> CC Configuration, Configuration Report, Param 23, Value 0x00
After reset the Z-Wave module, a DEVICE-RESET-LOCALLY-NOTIFICATION is sent.
Association group 1 supports 3 nodes.
Group 2: CTRL
On/Off Report when load state is changed:
On -> CC Basic, Basic Report, Value 0x01 - 0x63 Report the dimming level
Off -> CC Basic, Basic Report, Value 0x00
Association group 2 supports 20 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Documentation Links