SR-ZV9092A Z-Wave Heating Thermostat

This describes the Z-Wave device SR-ZV9092A, manufactured by Namron with the thing type UID of namron_zv9092a_00_000.

The device is in the category of HVAC, defining Air condition devices, Fans.

SR-ZV9092A product image

The SR-ZV9092A supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Z-Wave 16A underfloor heating thermostat with a touch panel. Both internal and external temperature sensor supported.

Inclusion Information

Method 1:

Select ZWAVE INFO on Home Interface to enter into Z-Wave network management. Select Add, then short press button , the device will send out an inclusion request, Status will show “Inclusion...”. If there is no response from a gateway within 30 seconds, or if the inclusion failed, Status will show “Fail”. If included successfully, Status will show “Inclusion OK” and the device ID.

Method 2:

Set the gateway into inclusion mode, make sure the device is already removed from previous network and reset the power of the device. The device will be included automatically.

Exclusion Information

Select Remove, then short press button, the device will send out an exclusion request, Status will show “Exclusion...". If there is no response from a gateway within 30 seconds, or exclusion failed, Status will show “Fail”. If excluded successfully, Status will show “Exclusion OK” and the device ID will be displayed as 0.

General Usage Information

Channels

The following table summarises the channels available for the SR-ZV9092A -:

Channel Name Channel ID Channel Type Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Operating State thermostat_state thermostat_state Temperature Number
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (dry air) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (auto) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (away) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Alarm (heat) alarm_heat alarm_heat Fire Switch
Alarm (power) alarm_power alarm_power Energy Switch
Clock Time Offset time_offset time_offset Time Number
Sensor (temperature) 1 sensor_temperature1 sensor_temperature Temperature Number:Temperature
Thermostat mode 1 thermostat_mode1 thermostat_mode Temperature Number
Operating State 1 thermostat_state1 thermostat_state Temperature Number
Setpoint (heating) 1 thermostat_setpoint1 thermostat_setpoint Heating Number:Temperature
Setpoint (dry air) 1 thermostat_setpoint1 thermostat_setpoint Heating Number:Temperature
Setpoint (auto) 1 thermostat_setpoint1 thermostat_setpoint Heating Number:Temperature
Setpoint (away) 1 thermostat_setpoint1 thermostat_setpoint Heating Number:Temperature
Sensor (temperature) 2 sensor_temperature2 sensor_temperature Temperature Number:Temperature

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Operating State

Sets the thermostat operating state.

The thermostat_state channel is of type thermostat_state and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (dry air)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (auto)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (away)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Alarm (heat)

Indicates if a heat alarm is triggered.

The alarm_heat channel is of type alarm_heat and supports the Switch item and is in the Fire category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel is of type time_offset and supports the Number item and is in the Time category.

Sensor (temperature) 1

Indicates the current temperature.

The sensor_temperature1 channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Thermostat mode 1

Sets the thermostat.

The thermostat_mode1 channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Operating State 1

Sets the thermostat operating state.

The thermostat_state1 channel is of type thermostat_state and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (heating) 1

Sets the thermostat setpoint.

The thermostat_setpoint1 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (dry air) 1

Sets the thermostat setpoint.

The thermostat_setpoint1 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (auto) 1

Sets the thermostat setpoint.

The thermostat_setpoint1 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (away) 1

Sets the thermostat setpoint.

The thermostat_setpoint1 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Sensor (temperature) 2

Indicates the current temperature.

The sensor_temperature2 channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Device Configuration

The following table provides a summary of the 22 configuration parameters available in the SR-ZV9092A. Detailed information on each parameter can be found in the sections below.

Param Name Description
2 MaxCurrent Overcurrent Protection
3 Feedback Vibration and buzzer level
4 Recovery Recovery after loss of power
6 MaxTemp Overtemperature protection
7 Hysteresis Temperature hysteresis
8 AutoModeControl Auto mode temperature control
9 ExtSensorType Floor temperature sensor type
10 Sensor Temperature sensor selection
11 IntTempCorr Room/internal temperature sensor correction
12 ExtTempCorr Floor/external temperature sensor correction
13 DryingDuration Drying mode duration
14 PostDryMode Mode after drying cycle
16 ReportHysteresis Temperature report hysteresis
17 ReportInterval Periodic report interval for temperature and humidity
18 PowerReportHysteresis Power report hysteresis
19 CurrentReportHysteresis Current report hysteresis
20 VoltageReportHysteresis Voltage report hysteresis
21 MeterReportInterval Periodic report interval for the meter
22 Brightness OLED display brightness
23 DisplaySensor Display temperature sensor
24 TimeZone Time zone UTC offset
27 DisplayAutoOff Display auto off

Parameter 2: MaxCurrent

Overcurrent Protection Maximum overcurrent detection value in A. When the detected current is over this value, the device will turn off the relay and send NOTIFICATION CC.

****: Disable overcurrent detection
5-16: Maximum allowed current Values in the range 0 to 16 may be set.

The manufacturer defined default value is 16.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Feedback

Vibration and buzzer level Vibration and buzzer level triggered by pressing buttons:

****: Disabled
1: Low Level
2: High Level The following option values may be configured, in addition to values in the range 0 to 2 -:

Value Description
0 Disabled
1 Low
2 High

The manufacturer defined default value is 1 (Low).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Recovery

Recovery after loss of power Whether to recover to settings from before power failure or power reset:

****: Use default settings
1: Recover to settings before power failure or power reset The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Use default settings
1 Recover to settings before power failure or power reset

The manufacturer defined default value is 1 (Recover to settings before power failure or power reset).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 6: MaxTemp

Overtemperature protection Maximum temperature detection value in °C. When either temperature sensor is above this value, the device will turn off the relay and send NOTIFICATION CC:

****: Disabled
20-60: The maximum temperature in °C Values in the range 0 to 60 may be set.

The manufacturer defined default value is 45.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Hysteresis

Temperature hysteresis Temperature control hysteresis value setting, range is 0.5 °C to 2 °C with a unit of 0.1 °C:

5: Control hysteresis is 0.5 °C
6-19: Control hysteresis is 0.6-1.9 °C
20: Control hysteresis is 2 °C Values in the range 5 to 20 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: AutoModeControl

Auto mode temperature control Auto mode (energy save mode) temperature schedule:

****: Use schedule set by user
1: Use Energy_Save_Heating temperature set by THERMOSTAT_SETPOINT_SET The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Use schedule set by user
1 Use Energy_Save_Heating temperature set by THERMOSTAT_SETPOINT_SET

The manufacturer defined default value is 0 (Use schedule set by user).

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: ExtSensorType

Floor temperature sensor type Floor temperature sensor type:

1: NTC/10K B(25/50°C)=3950
2: NTC/15K B(25/50°C)=3950
3: NTC/50K B(25/50°C)=3950
4: NTC/100K B(25/50°C)=3950
5: NTC/12K B(25/50°C)=3950 The following option values may be configured, in addition to values in the range 1 to 5 -:

Value Description
1 NTC/10K B(25/50°C)=3950
2 NTC/15K B(25/50°C)=3950
3 NTC/50K B(25/50°C)=3950
4 NTC/100K B(25/50°C)=3950
5 NTC/12K B(25/50°C)=3950

The manufacturer defined default value is 1 (NTC/10K B(25/50°C)=3950).

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Sensor

Temperature sensor selection Temperature control reference sensor selection:

1: Room/internal sensor
2: Floor/external sensor
3: Room/internal and floor/external sensor The following option values may be configured, in addition to values in the range 1 to 3 -:

Value Description
1 Room/internal sensor
2 Floor/external sensor
3 Room/internal and floor/external sensor

The manufacturer defined default value is 1 (Room/internal sensor).

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: IntTempCorr

Room/internal temperature sensor correction Room/internal sensor temperature correction from -10 to 10 with 0.5 °C unit. This makes the effective range -5 °C to +5 °C.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range -10 to 10 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: ExtTempCorr

Floor/external temperature sensor correction Floor/external sensor temperature correction from -10 to 10 with 0.5 °C unit. This makes the effective range -5 °C to +5 °C.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range -10 to 10 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: DryingDuration

Drying mode duration Set how long the drying mode lasts, from 5 to 100 minutes. Values in the range 5 to 100 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: PostDryMode

Mode after drying cycle Set the mode after the drying mode ends:

****: Off
1: Manual mode (Comfort mode)
2: Auto mode (Energy Save mode)
3: Away mode Values in the range 1 to 3 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 16: ReportHysteresis

Temperature report hysteresis Temperature report hysteresis setting, range is 0.1 °C to 1 °C with a unit of 0.1 °C:

****: Reporting disabled
2-10: Report hysteresis is 0.1-1 °C Values in the range 0 to 10 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 17: ReportInterval

Periodic report interval for temperature and humidity Time interval for periodic report of temperature and humidity in seconds.

****: Periodic report disabled
30-28800: Time interval is between 30 seconds and 8 hours Values in the range 0 to 28800 may be set.

The manufacturer defined default value is 300.

This parameter has the configuration ID config_17_2 and is of type INTEGER.

Parameter 18: PowerReportHysteresis

Power report hysteresis Power report hysteresis setting in watts:

****: Reporting disabled
1-100: Report hysteresis is 1-100 watt. Values in the range 0 to 100 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_18_1 and is of type INTEGER.

Parameter 19: CurrentReportHysteresis

Current report hysteresis Current report hysteresis setting in 0.1 ampere:

****: Reporting disabled
1-10: Report hysteresis is 0.1-1 ampere. Values in the range 0 to 10 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_19_1 and is of type INTEGER.

Parameter 20: VoltageReportHysteresis

Voltage report hysteresis Voltage report hysteresis setting in volt:

****: Reporting disabled
1-10: Report hysteresis is 1-10 volt. Values in the range 0 to 10 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 21: MeterReportInterval

Periodic report interval for the meter Time interval for periodic report of meter:

60-2678400: Time interval is between 1 minute and 31 days Values in the range 60 to 2678400 may be set.

The manufacturer defined default value is 600.

This parameter has the configuration ID config_21_4 and is of type INTEGER.

Parameter 22: Brightness

OLED display brightness OLED display brightness when operating the device:

: Low level
1
: Mid level**
2**: High level The following option values may be configured, in addition to values in the range 0 to 2 -:

Value Description
0 Low
1 Medium
2 High

The manufacturer defined default value is 1 (Medium).

This parameter has the configuration ID config_22_1 and is of type INTEGER.

Parameter 23: DisplaySensor

Display temperature sensor Defines which temperature sensor will be displayed on the Home page:

****: Room/internal temperature
1: Floor/external temperature The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Room/internal temperature
1 Floor/external temperature

The manufacturer defined default value is 0 (Room/internal temperature).

This parameter has the configuration ID config_23_1 and is of type INTEGER.

Parameter 24: TimeZone

Time zone UTC offset The time zone offset from UTC in hours, from -12 to 12. Values in the range -12 to 12 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_24_1 and is of type INTEGER.

Parameter 27: DisplayAutoOff

Display auto off Enable or disable the display Auto off function when the interface is in standby:

****: Disabled

1: Enabled The following option values may be configured, in addition to values in the range 0 to 1 -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_27_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The SR-ZV9092A supports 2 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Lifeline

  1. Send Command Class DEVICE_RESET_LOCALLY_NOTIFICATION to associated devices of this group when factory reset the device.

  2. Send Command Class THERMOSTAT_SETPOINT_REPORT, THERMOSTAT_MODE_REPORT, THERMOSTAT_OPERATING_STATE_REPORT to associated devices of this group when operation mode and temperature change.

3 .Send Command Class NOTIFICATION_REPORT to associated devices of this group when overcurrent or overheat detected.

  1. Send Command Class METER_REPORT to associated devices of this group to report metering parameters.

Profile: AGI_LIFE_LINE (0x0001)

Association group 1 supports 1 node.

Group 2: HeatSet

Heat set Transfer Command Class THERMOSTAT_SETPOINT_SET, THERMOSTAT_MODE_SET to control other temperature control devices when operation changes.

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_METER_V3
COMMAND_CLASS_THERMOSTAT_MODE_V3
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_MULTI_CHANNEL_V4
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_TIME_PARAMETERS_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_SECURITY_2_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_THERMOSTAT_MODE_V3
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1