SR-ZV9092A Z-Wave Heating Thermostat
This describes the Z-Wave device SR-ZV9092A, manufactured by Namron with the thing type UID of namron_zv9092a_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The SR-ZV9092A supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
Z-Wave 16A underfloor heating thermostat with a touch panel. Both internal and external temperature sensor supported.
Inclusion Information
Method 1:
Select ZWAVE INFO on Home Interface to enter into Z-Wave network management. Select Add, then short press button , the device will send out an inclusion request, Status will show “Inclusion...”. If there is no response from a gateway within 30 seconds, or if the inclusion failed, Status will show “Fail”. If included successfully, Status will show “Inclusion OK” and the device ID.
Method 2:
Set the gateway into inclusion mode, make sure the device is already removed from previous network and reset the power of the device. The device will be included automatically.
Exclusion Information
Select Remove, then short press button, the device will send out an exclusion request, Status will show “Exclusion...". If there is no response from a gateway within 30 seconds, or exclusion failed, Status will show “Fail”. If excluded successfully, Status will show “Exclusion OK” and the device ID will be displayed as 0.
General Usage Information
Channels
The following table summarises the channels available for the SR-ZV9092A -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
Operating State | thermostat_state | thermostat_state | Temperature | Number |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (dry air) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (auto) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (away) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Alarm (heat) | alarm_heat | alarm_heat | Fire | Switch |
Alarm (power) | alarm_power | alarm_power | Energy | Switch |
Clock Time Offset | time_offset | time_offset | Time | Number |
Sensor (temperature) 1 | sensor_temperature1 | sensor_temperature | Temperature | Number:Temperature |
Thermostat mode 1 | thermostat_mode1 | thermostat_mode | Temperature | Number |
Operating State 1 | thermostat_state1 | thermostat_state | Temperature | Number |
Setpoint (heating) 1 | thermostat_setpoint1 | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (dry air) 1 | thermostat_setpoint1 | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (auto) 1 | thermostat_setpoint1 | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (away) 1 | thermostat_setpoint1 | thermostat_setpoint | Heating | Number:Temperature |
Sensor (temperature) 2 | sensor_temperature2 | sensor_temperature | Temperature | Number:Temperature |
Sensor (temperature)
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Electric meter (kWh)
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (watts)
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (volts)
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (amps)
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Thermostat mode
Sets the thermostat.
The thermostat_mode
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Operating State
Sets the thermostat operating state.
The thermostat_state
channel is of type thermostat_state
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Setpoint (heating)
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Setpoint (dry air)
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Setpoint (auto)
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Setpoint (away)
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Alarm (heat)
Indicates if a heat alarm is triggered.
The alarm_heat
channel is of type alarm_heat
and supports the Switch
item and is in the Fire
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Alarm (power)
Indicates if a power alarm is triggered.
The alarm_power
channel is of type alarm_power
and supports the Switch
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Clock Time Offset
Provides the current time difference for the devices time.
The time_offset
channel is of type time_offset
and supports the Number
item and is in the Time
category.
Sensor (temperature) 1
Indicates the current temperature.
The sensor_temperature1
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Thermostat mode 1
Sets the thermostat.
The thermostat_mode1
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Operating State 1
Sets the thermostat operating state.
The thermostat_state1
channel is of type thermostat_state
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Setpoint (heating) 1
Sets the thermostat setpoint.
The thermostat_setpoint1
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Setpoint (dry air) 1
Sets the thermostat setpoint.
The thermostat_setpoint1
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Setpoint (auto) 1
Sets the thermostat setpoint.
The thermostat_setpoint1
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Setpoint (away) 1
Sets the thermostat setpoint.
The thermostat_setpoint1
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Sensor (temperature) 2
Indicates the current temperature.
The sensor_temperature2
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Device Configuration
The following table provides a summary of the 22 configuration parameters available in the SR-ZV9092A. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
2 | MaxCurrent | Overcurrent Protection |
3 | Feedback | Vibration and buzzer level |
4 | Recovery | Recovery after loss of power |
6 | MaxTemp | Overtemperature protection |
7 | Hysteresis | Temperature hysteresis |
8 | AutoModeControl | Auto mode temperature control |
9 | ExtSensorType | Floor temperature sensor type |
10 | Sensor | Temperature sensor selection |
11 | IntTempCorr | Room/internal temperature sensor correction |
12 | ExtTempCorr | Floor/external temperature sensor correction |
13 | DryingDuration | Drying mode duration |
14 | PostDryMode | Mode after drying cycle |
16 | ReportHysteresis | Temperature report hysteresis |
17 | ReportInterval | Periodic report interval for temperature and humidity |
18 | PowerReportHysteresis | Power report hysteresis |
19 | CurrentReportHysteresis | Current report hysteresis |
20 | VoltageReportHysteresis | Voltage report hysteresis |
21 | MeterReportInterval | Periodic report interval for the meter |
22 | Brightness | OLED display brightness |
23 | DisplaySensor | Display temperature sensor |
24 | TimeZone | Time zone UTC offset |
27 | DisplayAutoOff | Display auto off |
Parameter 2: MaxCurrent
Overcurrent Protection Maximum overcurrent detection value in A. When the detected current is over this value, the device will turn off the relay and send NOTIFICATION CC.
****: Disable overcurrent detection
5-16: Maximum allowed current
Values in the range 0 to 16 may be set.
The manufacturer defined default value is 16
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: Feedback
Vibration and buzzer level Vibration and buzzer level triggered by pressing buttons:
****: Disabled
1: Low Level
2: High Level
The following option values may be configured, in addition to values in the range 0 to 2 -:
Value | Description |
---|---|
0 | Disabled |
1 | Low |
2 | High |
The manufacturer defined default value is 1
(Low).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: Recovery
Recovery after loss of power Whether to recover to settings from before power failure or power reset:
****: Use default settings
1: Recover to settings before power failure or power reset
The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | Use default settings |
1 | Recover to settings before power failure or power reset |
The manufacturer defined default value is 1
(Recover to settings before power failure or power reset).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 6: MaxTemp
Overtemperature protection Maximum temperature detection value in °C. When either temperature sensor is above this value, the device will turn off the relay and send NOTIFICATION CC:
****: Disabled
20-60: The maximum temperature in °C
Values in the range 0 to 60 may be set.
The manufacturer defined default value is 45
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Parameter 7: Hysteresis
Temperature hysteresis Temperature control hysteresis value setting, range is 0.5 °C to 2 °C with a unit of 0.1 °C:
5: Control hysteresis is 0.5 °C
6-19: Control hysteresis is 0.6-1.9 °C
20: Control hysteresis is 2 °C
Values in the range 5 to 20 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Parameter 8: AutoModeControl
Auto mode temperature control Auto mode (energy save mode) temperature schedule:
****: Use schedule set by user
1: Use Energy_Save_Heating temperature set by THERMOSTAT_SETPOINT_SET
The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | Use schedule set by user |
1 | Use Energy_Save_Heating temperature set by THERMOSTAT_SETPOINT_SET |
The manufacturer defined default value is 0
(Use schedule set by user).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Parameter 9: ExtSensorType
Floor temperature sensor type Floor temperature sensor type:
1: NTC/10K B(25/50°C)=3950
2: NTC/15K B(25/50°C)=3950
3: NTC/50K B(25/50°C)=3950
4: NTC/100K B(25/50°C)=3950
5: NTC/12K B(25/50°C)=3950
The following option values may be configured, in addition to values in the range 1 to 5 -:
Value | Description |
---|---|
1 | NTC/10K B(25/50°C)=3950 |
2 | NTC/15K B(25/50°C)=3950 |
3 | NTC/50K B(25/50°C)=3950 |
4 | NTC/100K B(25/50°C)=3950 |
5 | NTC/12K B(25/50°C)=3950 |
The manufacturer defined default value is 1
(NTC/10K B(25/50°C)=3950).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Parameter 10: Sensor
Temperature sensor selection Temperature control reference sensor selection:
1: Room/internal sensor
2: Floor/external sensor
3: Room/internal and floor/external sensor
The following option values may be configured, in addition to values in the range 1 to 3 -:
Value | Description |
---|---|
1 | Room/internal sensor |
2 | Floor/external sensor |
3 | Room/internal and floor/external sensor |
The manufacturer defined default value is 1
(Room/internal sensor).
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Parameter 11: IntTempCorr
Room/internal temperature sensor correction Room/internal sensor temperature correction from -10 to 10 with 0.5 °C unit. This makes the effective range -5 °C to +5 °C.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range -10 to 10 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Parameter 12: ExtTempCorr
Floor/external temperature sensor correction Floor/external sensor temperature correction from -10 to 10 with 0.5 °C unit. This makes the effective range -5 °C to +5 °C.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range -10 to 10 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Parameter 13: DryingDuration
Drying mode duration Set how long the drying mode lasts, from 5 to 100 minutes. Values in the range 5 to 100 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Parameter 14: PostDryMode
Mode after drying cycle Set the mode after the drying mode ends:
****: Off
1: Manual mode (Comfort mode)
2: Auto mode (Energy Save mode)
3: Away mode
Values in the range 1 to 3 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
Parameter 16: ReportHysteresis
Temperature report hysteresis Temperature report hysteresis setting, range is 0.1 °C to 1 °C with a unit of 0.1 °C:
****: Reporting disabled
2-10: Report hysteresis is 0.1-1 °C
Values in the range 0 to 10 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
Parameter 17: ReportInterval
Periodic report interval for temperature and humidity Time interval for periodic report of temperature and humidity in seconds.
****: Periodic report disabled
30-28800: Time interval is between 30 seconds and 8 hours
Values in the range 0 to 28800 may be set.
The manufacturer defined default value is 300
.
This parameter has the configuration ID config_17_2
and is of type INTEGER
.
Parameter 18: PowerReportHysteresis
Power report hysteresis Power report hysteresis setting in watts:
****: Reporting disabled
1-100: Report hysteresis is 1-100 watt.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_18_1
and is of type INTEGER
.
Parameter 19: CurrentReportHysteresis
Current report hysteresis Current report hysteresis setting in 0.1 ampere:
****: Reporting disabled
1-10: Report hysteresis is 0.1-1 ampere.
Values in the range 0 to 10 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_19_1
and is of type INTEGER
.
Parameter 20: VoltageReportHysteresis
Voltage report hysteresis Voltage report hysteresis setting in volt:
****: Reporting disabled
1-10: Report hysteresis is 1-10 volt.
Values in the range 0 to 10 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
Parameter 21: MeterReportInterval
Periodic report interval for the meter Time interval for periodic report of meter:
60-2678400: Time interval is between 1 minute and 31 days Values in the range 60 to 2678400 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_21_4
and is of type INTEGER
.
Parameter 22: Brightness
OLED display brightness OLED display brightness when operating the device:
: Low level
1: Mid level**
2**: High level
The following option values may be configured, in addition to values in the range 0 to 2 -:
Value | Description |
---|---|
0 | Low |
1 | Medium |
2 | High |
The manufacturer defined default value is 1
(Medium).
This parameter has the configuration ID config_22_1
and is of type INTEGER
.
Parameter 23: DisplaySensor
Display temperature sensor Defines which temperature sensor will be displayed on the Home page:
****: Room/internal temperature
1: Floor/external temperature
The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | Room/internal temperature |
1 | Floor/external temperature |
The manufacturer defined default value is 0
(Room/internal temperature).
This parameter has the configuration ID config_23_1
and is of type INTEGER
.
Parameter 24: TimeZone
Time zone UTC offset The time zone offset from UTC in hours, from -12 to 12. Values in the range -12 to 12 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_24_1
and is of type INTEGER
.
Parameter 27: DisplayAutoOff
Display auto off Enable or disable the display Auto off function when the interface is in standby:
****: Disabled
1: Enabled The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_27_1
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The SR-ZV9092A supports 2 association groups.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Lifeline
-
Send Command Class DEVICE_RESET_LOCALLY_NOTIFICATION to associated devices of this group when factory reset the device.
-
Send Command Class THERMOSTAT_SETPOINT_REPORT, THERMOSTAT_MODE_REPORT, THERMOSTAT_OPERATING_STATE_REPORT to associated devices of this group when operation mode and temperature change.
3 .Send Command Class NOTIFICATION_REPORT to associated devices of this group when overcurrent or overheat detected.
- Send Command Class METER_REPORT to associated devices of this group to report metering parameters.
Profile: AGI_LIFE_LINE (0x0001)
Association group 1 supports 1 node.
Group 2: HeatSet
Heat set Transfer Command Class THERMOSTAT_SETPOINT_SET, THERMOSTAT_MODE_SET to control other temperature control devices when operation changes.
Association group 2 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_THERMOSTAT_MODE_V3 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2 | |
COMMAND_CLASS_TRANSPORT_SERVICE_V2 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_V4 | |
COMMAND_CLASS_SUPERVISION_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V8 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V3 | |
COMMAND_CLASS_TIME_PARAMETERS_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | |
COMMAND_CLASS_SECURITY_V1 | |
COMMAND_CLASS_SECURITY_2_V1 |
Endpoint 1
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_THERMOSTAT_MODE_V3 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | |
COMMAND_CLASS_SECURITY_V1 |
Endpoint 2
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | |
COMMAND_CLASS_SECURITY_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.