openhab-docs/_addons_bindings/zwave/doc/ge/zw1002_0_0.md

5.3 KiB

layout title
documentation ZW1002 - ZWave

{% include base.html %}

ZW1002 Smart Outlet

This describes the Z-Wave device ZW1002, manufactured by Jasco Products with the thing type UID of ge_zw1002_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

ZW1002 product image

The ZW1002 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

When paired with a compatible hub, the smart outlet controls and schedules plug-in devices through ON/OFF commands and programmed settings. Wirelessly operate lamps, fans, small appliances and more for effortless management of your home. 

Inclusion Information

  1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.
  2. Once the controller is ready to add your device, press and release the program button to add it in the network.

Exclusion Information

  1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.
  2. Once the controller is ready to remove your device, press and release the manual/program button to remove it from the network.

General Usage Information

Channels

The following table summarises the channels available for the ZW1002 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the ZW1002. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 LED Light LED Light
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: LED Light

LED Light

The following option values may be configured, in addition to values in the range 0 to 2 -:

Value Description
0 LED ON when load is ON
1 LED ON when load is OFF
2 LED always OFF

The manufacturer defined default value is 0 (LED ON when load is ON).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZW1002 supports 3 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline

Association group 1 supports 5 nodes.

Group 2: Single Press

Supports Basic Set and is controlled with the local load

Association group 2 supports 5 nodes.

Group 3: Double Press

Supports Basic Set and is controlled by pressing the On or Off button

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.