openhab-docs/_addons_bindings/zwave/doc/everspring/an301_0_0.md

4.8 KiB
Raw Permalink Blame History

layout title
documentation AN301 - ZWave

{% include base.html %}

AN301 Switch Plugin

This describes the Z-Wave device AN301, manufactured by Everspring with the thing type UID of everspring_an301_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

AN301 product image

The AN301 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Plug-in ON/OFF Module (Z-Wave Plus version of AN157)
UK version: AN301-3 
Chile version: AN301-7

Inclusion Information

Push the ON/OFF button three times within 1.5 seconds

Exclusion Information

Push the ON/OFF button three times within 1.5 seconds

General Usage Information

Channels

The following table summarises the channels available for the AN301 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Alarm (power) alarm_power alarm_power Energy Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the AN301. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 Remember the last status

Parameter 3: Remember the last status

Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The AN301 supports 2 association groups.

Group 1: General

Binary Switch Report The unit supports two association groups with 1 node support for Grouping 1 and 5 nodes support for Grouping 2. This has the effect that when the unit is operating, all devices associated with the unit will receive the relevant reports.

When the unit is powered for the first time, the unit will send a Notification Report to the node of Group 1.

When setting the unit or changing the units status, the unit will send a Binary Switch Report to the node of Group 1.

When performing Reset the unit will send Device Reset Locally Notification to the node of Group1.

Association group 1 supports 1 node.

Group 2: Control

Basic Set, Notification Report, Device Reset Locally Notification On/Off control (Button1)

When the button on the unit or the wall switch is pressed, the unit will send a Basic Set command to the nodes of Group 2. When the unit is OFF, Basic Set Value = 0x00. When the unit is ON, Basic Set Value = 0xFF

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_TRANSPORT_SERVICE_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_2_V1

Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.