4.7 KiB
layout | title |
---|---|
documentation | ISZW7-ECO - ZWave |
{% include base.html %}
ISZW7-ECO Z-Wave 700 Chime + Siren
This describes the Z-Wave device ISZW7-ECO, manufactured by Ecolink with the thing type UID of eco_chimesiren700_00_000
.
The device is in the category of Battery, defining Batteries, Energy Storages.
The ISZW7-ECO supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
Z-Wave Chime and Siren with 20 built in sounds, support for custom sounds via 16GB or 32GB FAT32 SDHC card.
Plugs into standard AC outlet and contains a battery backup.
Suitable for door entry chimes, sensor alarms, etc.
Inclusion Information
Start by placing the controller into inclusion mode.
Classic Inclusion:
Activate inclusion mode for the siren by pressing the pair button on the side of its chassis (not to be confused with the volume up and down buttons).
S2 secure pairing (untested):
Use the DSK QR code or 5 digit PIN printed on the unit
Exclusion Information
Start by placing the controller into exclusion mode.Exclusion mode on the sensor is performed following the same exact procedure as inclusion.
General Usage Information
Channels
The following table summarises the channels available for the ISZW7-ECO -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Alarm (system) | alarm_system | alarm_system | Switch | |
Alarm (power) | alarm_power | alarm_power | Energy | Switch |
Battery Level | battery-level | system.battery_level | Battery | Number |
Alarm (system)
Indicates if a system alarm is triggered.
The alarm_system
channel is of type alarm_system
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Alarm (power)
Indicates if a power alarm is triggered.
The alarm_power
channel is of type alarm_power
and supports the Switch
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Battery Level
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
Device Configuration
The device has no configuration parameters defined.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_TRANSPORT_SERVICE_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_SUPERVISION_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V8 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_INDICATOR_V3 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | |
COMMAND_CLASS_SECURITY_V1 | |
COMMAND_CLASS_SECURITY_2_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.