Da Vinci v9
This describes the Z-Wave device Da Vinci v9, manufactured by Avadesign Technology Co. with the thing type UID of avadesign_davinciv9_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The Da Vinci v9 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
Overview
The Da Vinci wall controller is a Multi Chanel Z-Wave device that contains up to 6 relays and up to 9 touch buttons that can be set to control either the relays (On/Off switches and shutters) or any other on/off (SWITCH_BINARY) , shutter (MULTILEVEL_SWITCH) Z-Wave device.
Double Press the following buttons in the following order 8,1,3. Use the reset procedure only when the primary controller is missing or inoperable.
Inclusion Information
Press the #1 button 3 times.
Exclusion Information
Press the #1 button 3 times.
Channels
The following table summarises the channels available for the Da Vinci v9 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary1 | switch_binary | Switch | Switch |
Switch
Switch the power on and off.
The switch_binary1
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Device Configuration
The following table provides a summary of the 51 configuration parameters available in the Da Vinci v9. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Button 1 Type | button 1 Type |
2 | Button 1 Partner-Id | Button 1 Partner-Id |
3 | Button 1 Blind Duration | Button 1 Blind Duration |
4 | Button 1 Output | Button 1 Output |
5 | Button 1 attributes | Button 1 attributes |
6 | Button 2 Type | Button 2 Type |
7 | Button 2 Partner-Id | Button 2 Partner-Id |
8 | Button 2 Blind Duration | Button 2 Blind Duration |
9 | Button 2 Output | Button 2 Output |
10 | Button 2 attributes | Button 2 attributes |
11 | Button 3 Type | Button 3 Type |
12 | Button 3 Partner-Id | Button 3 Partner-Id |
13 | Button 3 Blind Duration | Button 3 Blind Duration |
14 | Button 3 Output | Button 3 Output |
15 | Button 3 attributes | Button 3 attributes |
16 | Button 4 Type | Button 4 Type |
17 | Button 4 Partner-Id | Button 4 Partner-Id |
18 | Button 4 Blind Duration | Button 4 Blind Duration |
19 | Button 4 Output | Button 4 Output |
20 | Button 4 attributes | Button 4 attributes |
21 | Button 5 Type | Button 5 Type |
22 | Button 5 Partner-Id | Button 5 Partner-Id |
23 | Button 5 Blind Duration | Button 5 Blind Duration |
24 | Button 5 Output | Button 5 Output |
25 | Button 5 attributes | Button 5 attributes |
26 | Button 6 Type | Button 6 Type |
27 | Button 6 Partner-Id | Button 6 Partner-Id |
28 | Button 6 Blind Duration | Button 6 Blind Duration |
29 | Button 6 Output | Button 6 Output |
30 | Button 6 attributes | Button 6 attributes |
31 | Button 7 Type | Button 7 Type |
32 | Button 7 Partner-Id | Button 7 Partner-Id |
33 | Button 7 Blind Duration | Button 7 Blind Duration |
34 | Button 7 Output | Button 7 Output |
35 | Button 7 attribute | Button 7 attribute |
36 | Button 8 Type | Button 8 Type |
37 | Button 8 Partner-Id | Button 8 Partner-Id |
38 | Button 8 Blind Duration | Button 8 Blind Duration |
39 | Button 8 Output | Button 8 Output |
40 | Button 8 attribute | Button 8 attribute |
41 | Button 9 Type | Button 9 Type |
42 | Button 9 Partner-Id | Button 9 Partner-Id |
43 | Button 9 Blind Duration | Button 9 Blind Duration |
44 | Button 9 Output | Button 9 Output |
45 | Button 9 attributes | Button 9 attributes |
46 | Device Led on intensity | Device Led on intensity |
47 | Device Led off intensity | Device Led off intensity |
48 | Device Toggle or Pulse the output | Device Toggle or Pulse the output |
49 | Device Background LEDs Timeout | Device Background LEDs Timeout |
50 | Device touch sensitivity | Device touch sensitivity |
51 | Save and Reset | Save and Reset |
Parameter 1: Button 1 Type
button 1 Type 1 = switch on/off
2 = blind up
3 = blind down
4 = switch multiway
5 = blind-up multiway
6 = blind-down multiway The following option values may be configured -:
Value | Description |
---|---|
0 | Null |
1 | Switch On/Off |
2 | Blind up |
3 | Blind down |
4 | Switch multiway |
5 | Blind-up multiway |
6 | Blind-down multiway |
The manufacturer defined default value is 1
(Switch On/Off).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Button 1 Partner-Id
Button 1 Partner-Id
- When setting Button (EP) to blind, Partner Id EP also change to blind (opposite direction).
- Blind must contain Partner Id which is different than 0 and it must be unique.
- When setting blind to switch, Partner Id also change to switch The following option values may be configured -:
Value | Description |
---|---|
0 | Partner-Id 0 |
1 | Partner-Id 1 |
2 | Partner-Id 2 |
3 | Partner-Id 3 |
4 | Partner-Id 4 |
5 | Partner-Id 5 |
6 | Partner-Id 6 |
7 | Partner-Id 7 |
8 | Partner-Id 8 |
9 | Partner-Id 9 |
The manufacturer defined default value is 0
(Partner-Id 0).
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Parameter 3: Button 1 Blind Duration
Button 1 Blind Duration
The following option values may be configured -:
Value | Description |
---|---|
3 | Duration 3 Seconds |
10 | Duration 10 Seconds |
30 | Duration 30 Seconds |
60 | Duration 60 Seconds |
90 | Duration 90 Seconds |
120 | Duration 120 Seconds |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: Button 1 Output
Button 1 Output Output = Relay The following option values may be configured -:
Value | Description |
---|---|
0 | No output |
1 | Output number 1 |
2 | Output number 2 |
3 | Output number 3 |
4 | Output number 4 |
5 | Output number 5 |
6 | Output number 6 |
The manufacturer defined default value is 1
(Output number 1).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 5: Button 1 attributes
Button 1 attributes Bit [0] = LED enable
Bit [1] = Sound enable
Bit [2] = Dry contact enable
Bit [3] = Motor enable The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Only Led |
2 | Only Sound |
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter 6: Button 2 Type
Button 2 Type 1 = switch on/off
2 = blind up
3 = blind down
4 = switch multiway
5 = blind-up multiway
6 = blind-down multiway The following option values may be configured -:
Value | Description |
---|---|
1 | Switch On/Off |
2 | Blind up |
3 | Blind down |
4 | Switch multiway |
5 | Blind-up multiway |
6 | Blind-down multiway |
The manufacturer defined default value is 1
(Switch On/Off).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Parameter 7: Button 2 Partner-Id
Button 2 Partner-Id
- When setting Button (EP) to blind, Partner Id EP also change to blind (opposite direction).
- Blind must contain Partner Id which is different than 0 and it must be unique.
- When setting blind to switch, Partner Id also change to switch The following option values may be configured -:
Value | Description |
---|---|
0 | Partner-Id 0 |
1 | Partner-Id 1 |
2 | Partner-Id 2 |
3 | Partner-Id 3 |
4 | Partner-Id 4 |
5 | Partner-Id 5 |
6 | Partner-Id 6 |
7 | Partner-Id 7 |
8 | Partner-Id 8 |
9 | Partner-Id 9 |
The manufacturer defined default value is 0
(Partner-Id 0).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Parameter 8: Button 2 Blind Duration
Button 2 Blind Duration Possible values
3-127 The following option values may be configured -:
Value | Description |
---|---|
3 | Duration 3 Seconds |
10 | Duration10 Seconds |
30 | Duration 30 Seconds |
60 | Duration 60 Seconds |
90 | Duration 90 Seconds |
120 | Duration 120 Seconds |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Parameter 9: Button 2 Output
Button 2 Output
The following option values may be configured -:
Value | Description |
---|---|
0 | No output |
1 | Output number 1 |
2 | Output number 2 |
3 | Output number 3 |
4 | Output number 4 |
5 | Output number 5 |
6 | Output number 6 |
The manufacturer defined default value is 2
(Output number 2).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Parameter 10: Button 2 attributes
Button 2 attributes Bit [0] = LED enable
Bit [1] = Sound enable
Bit [2] = Dry contact enable
Bit [3] = Motor enable The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Only Led |
2 | Only Sound |
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Parameter 11: Button 3 Type
Button 3 Type 1 = switch on/off
2 = blind up
3 = blind down
4 = switch multiway
5 = blind-up multiway
6 = blind-down multiway The following option values may be configured -:
Value | Description |
---|---|
1 | Switch On/Off |
2 | Blind up |
3 | Blind down |
4 | Switch multiway |
5 | Blind-up multiway |
6 | Blind-down multiway |
The manufacturer defined default value is 1
(Switch On/Off).
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Parameter 12: Button 3 Partner-Id
Button 3 Partner-Id
- When setting Button (EP) to blind, Partner Id EP also change to blind (opposite direction).
- Blind must contain Partner Id which is different than 0 and it must be unique.
- When setting blind to switch, Partner Id also change to switch The following option values may be configured -:
Value | Description |
---|---|
0 | Partner-Id 0 |
1 | Partner-Id 1 |
2 | Partner-Id 2 |
3 | Partner-Id 3 |
4 | Partner-Id 4 |
5 | Partner-Id 5 |
6 | Partner-Id 6 |
7 | Partner-Id 7 |
8 | Partner-Id 8 |
9 | Partner-Id 9 |
The manufacturer defined default value is 0
(Partner-Id 0).
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Parameter 13: Button 3 Blind Duration
Button 3 Blind Duration
The following option values may be configured -:
Value | Description |
---|---|
3 | Duration 3 Seconds |
30 | Duration 30 Seconds |
60 | Duration 60 Seconds |
90 | Duration 90 Seconds |
120 | Duration 120 Seconds |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Parameter 14: Button 3 Output
Button 3 Output
The following option values may be configured -:
Value | Description |
---|---|
0 | No output |
1 | Output number 1 |
2 | Output number 2 |
3 | Output number 3 |
4 | Output number 4 |
5 | Output number 5 |
6 | Output number 6 |
The manufacturer defined default value is 3
(Output number 3).
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
Parameter 15: Button 3 attributes
Button 3 attributes Bit [0] = LED enable
Bit [1] = Sound enable
Bit [2] = Dry contact enable
Bit [3] = Motor enable The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Only Led |
2 | Only Sound |
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
Parameter 16: Button 4 Type
Button 4 Type 1 = switch on/off
2 = blind up
3 = blind down
4 = switch multiway
5 = blind-up multiway
6 = blind-down multiway The following option values may be configured -:
Value | Description |
---|---|
1 | Switch On/Off |
2 | Blind up |
3 | Blind down |
4 | Switch multiway |
5 | Blind-up multiway |
6 | Blind-down multiway |
The manufacturer defined default value is 1
(Switch On/Off).
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
Parameter 17: Button 4 Partner-Id
Button 4 Partner-Id
- When setting Button (EP) to blind, Partner Id EP also change to blind (opposite direction).
- Blind must contain Partner Id which is different than 0 and it must be unique.
- When setting blind to switch, Partner Id also change to switch The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Partner-Id 1 |
2 | Partner-Id 2 |
3 | Partner-Id 3 |
4 | Partner-Id 4 |
5 | Partner-Id 5 |
6 | Partner-Id 6 |
7 | Partner-Id 7 |
8 | Partner-Id 8 |
9 | Partner-Id 9 |
The manufacturer defined default value is 0
(None).
This parameter has the configuration ID config_17_1
and is of type INTEGER
.
Parameter 18: Button 4 Blind Duration
Button 4 Blind Duration
The following option values may be configured -:
Value | Description |
---|---|
3 | Duration 3 Seconds |
30 | Duration 30 Seconds |
60 | Duration 60 Seconds |
90 | Duration 90 Seconds |
120 | Duration 120 Seconds |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_18_1
and is of type INTEGER
.
Parameter 19: Button 4 Output
Button 4 Output
The following option values may be configured -:
Value | Description |
---|---|
0 | No output |
1 | Output number 1 |
2 | Output number 2 |
3 | Output number 3 |
4 | Output number 4 |
5 | Output number 5 |
6 | Output number 6 |
The manufacturer defined default value is 4
(Output number 4).
This parameter has the configuration ID config_19_1
and is of type INTEGER
.
Parameter 20: Button 4 attributes
Button 4 attributes Bit [0] = LED enable
Bit [1] = Sound enable
Bit [2] = Dry contact enable
Bit [3] = Motor enable The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Only Led |
2 | Only Sound |
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
Parameter 21: Button 5 Type
Button 5 Type 1 = switch on/off
2 = blind up
3 = blind down
4 = switch multiway
5 = blind-up multiway
6 = blind-down multiway The following option values may be configured -:
Value | Description |
---|---|
1 | Switch On/Off |
2 | Blind up |
3 | Blind down |
4 | Switch multiway |
5 | Blind-up multiway |
6 | Blind-down multiway |
The manufacturer defined default value is 1
(Switch On/Off).
This parameter has the configuration ID config_21_1
and is of type INTEGER
.
Parameter 22: Button 5 Partner-Id
Button 5 Partner-Id
- When setting Button (EP) to blind, Partner Id EP also change to blind (opposite direction).
- Blind must contain Partner Id which is different than 0 and it must be unique.
- When setting blind to switch, Partner Id also change to switch The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Partner-Id 1 |
2 | Partner-Id 2 |
3 | Partner-Id 3 |
4 | Partner-Id 4 |
5 | Partner-Id 5 |
6 | Partner-Id 6 |
7 | Partner-Id 7 |
8 | Partner-Id 8 |
9 | Partner-Id 9 |
The manufacturer defined default value is 0
(None).
This parameter has the configuration ID config_22_1
and is of type INTEGER
.
Parameter 23: Button 5 Blind Duration
Button 5 Blind Duration
The following option values may be configured -:
Value | Description |
---|---|
3 | Duration 3 Seconds |
30 | Duration 30 Seconds |
60 | Duration 60 Seconds |
90 | Duration 90 Seconds |
120 | Duration 120 Seconds |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_23_1
and is of type INTEGER
.
Parameter 24: Button 5 Output
Button 5 Output
The following option values may be configured -:
Value | Description |
---|---|
0 | No output |
1 | Output number 1 |
2 | Output number 2 |
3 | Output number 3 |
4 | Output number 4 |
5 | Output number 5 |
6 | Output number 6 |
The manufacturer defined default value is 6
(Output number 6).
This parameter has the configuration ID config_24_1
and is of type INTEGER
.
Parameter 25: Button 5 attributes
Button 5 attributes Bit [0] = LED enable
Bit [1] = Sound enable
Bit [2] = Dry contact enable
Bit [3] = Motor enable The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Only Led |
2 | Only Sound |
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_25_1
and is of type INTEGER
.
Parameter 26: Button 6 Type
Button 6 Type 1 = switch on/off
2 = blind up
3 = blind down
4 = switch multiway
5 = blind-up multiway
6 = blind-down multiway The following option values may be configured -:
Value | Description |
---|---|
1 | Switch On/Off |
2 | Blind up |
3 | Blind down |
4 | Switch multiway |
5 | Blind-up multiway |
6 | Blind-down multiway |
The manufacturer defined default value is 1
(Switch On/Off).
This parameter has the configuration ID config_26_1
and is of type INTEGER
.
Parameter 27: Button 6 Partner-Id
Button 6 Partner-Id
- When setting Button (EP) to blind, Partner Id EP also change to blind (opposite direction).
- Blind must contain Partner Id which is different than 0 and it must be unique.
- When setting blind to switch, Partner Id also change to switch The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Partner-Id 1 |
2 | Partner-Id 2 |
3 | Partner-Id 3 |
4 | Partner-Id 4 |
5 | Partner-Id 5 |
6 | Partner-Id 6 |
7 | Partner-Id 7 |
8 | Partner-Id 8 |
9 | Partner-Id 9 |
The manufacturer defined default value is 0
(None).
This parameter has the configuration ID config_27_1
and is of type INTEGER
.
Parameter 28: Button 6 Blind Duration
Button 6 Blind Duration
The following option values may be configured -:
Value | Description |
---|---|
3 | Duration 3 Seconds |
30 | Duration 30 Seconds |
60 | Duration 60 Seconds |
90 | Duration 90 Seconds |
120 | Duration 120 Seconds |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_28_1
and is of type INTEGER
.
Parameter 29: Button 6 Output
Button 6 Output
The following option values may be configured -:
Value | Description |
---|---|
0 | No output |
1 | Output number 1 |
2 | Output number 2 |
3 | Output number 3 |
4 | Output number 4 |
5 | Output number 5 |
6 | Output number 6 |
The manufacturer defined default value is 6
(Output number 6).
This parameter has the configuration ID config_29_1
and is of type INTEGER
.
Parameter 30: Button 6 attributes
Button 6 attributes Bit [0] = LED enable
Bit [1] = Sound enable
Bit [2] = Dry contact enable
Bit [3] = Motor enable The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Only Led |
2 | Only Sound |
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
Parameter 31: Button 7 Type
Button 7 Type 1 = switch on/off
2 = blind up
3 = blind down
4 = switch multiway
5 = blind-up multiway
6 = blind-down multiway The following option values may be configured -:
Value | Description |
---|---|
1 | On/Off Switch |
2 | Blind up |
3 | Blind down |
4 | Switch multiway |
5 | Blind-up multiway |
6 | Blind-down multiway |
The manufacturer defined default value is 1
(On/Off Switch).
This parameter has the configuration ID config_31_1
and is of type INTEGER
.
Parameter 32: Button 7 Partner-Id
Button 7 Partner-Id
- When setting Button (EP) to blind, Partner Id EP also change to blind (opposite direction).
- Blind must contain Partner Id which is different than 0 and it must be unique.
- When setting blind to switch, Partner Id also change to switch The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Partner-Id 1 |
2 | Partner-Id 2 |
3 | Partner-Id 3 |
4 | Partner-Id 4 |
5 | Partner-Id 5 |
6 | Partner-Id 6 |
7 | Partner-Id 7 |
8 | Partner-Id 8 |
9 | Partner-Id 9 |
The manufacturer defined default value is 0
(None).
This parameter has the configuration ID config_32_1
and is of type INTEGER
.
Parameter 33: Button 7 Blind Duration
Button 7 Blind Duration
The following option values may be configured -:
Value | Description |
---|---|
3 | Duration 3 Seconds |
30 | Duration 30 Seconds |
60 | Duration 60 Seconds |
90 | Duration 90 Seconds |
120 | Duration 120 Seconds |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_33_1
and is of type INTEGER
.
Parameter 34: Button 7 Output
Button 7 Output
The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Output number 1 |
2 | Output number 2 |
3 | Output number 3 |
4 | Output number 4 |
5 | Output number 5 |
6 | Output number 6 |
The manufacturer defined default value is 0
(None).
This parameter has the configuration ID config_34_1
and is of type INTEGER
.
Parameter 35: Button 7 attribute
Button 7 attribute Bit [0] = LED enable
Bit [1] = Sound enable
Bit [2] = Dry contact enable
Bit [3] = Motor enable The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Only Led |
2 | Only Sound |
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_35_1
and is of type INTEGER
.
Parameter 36: Button 8 Type
Button 8 Type 1 = switch on/off
2 = blind up
3 = blind down
4 = switch multiway
5 = blind-up multiway
6 = blind-down multiway The following option values may be configured -:
Value | Description |
---|---|
1 | Switch On/Off |
2 | Blind up |
3 | Blind down |
4 | Switch multiway |
5 | Blind-up multiway |
6 | Blind-down multiway |
The manufacturer defined default value is 1
(Switch On/Off).
This parameter has the configuration ID config_36_1
and is of type INTEGER
.
Parameter 37: Button 8 Partner-Id
Button 8 Partner-Id
- When setting Button (EP) to blind, Partner Id EP also change to blind (opposite direction).
- Blind must contain Partner Id which is different than 0 and it must be unique.
- When setting blind to switch, Partner Id also change to switch The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Partner-Id 1 |
2 | Partner-Id 2 |
3 | Partner-Id 3 |
4 | Partner-Id 4 |
5 | Partner-Id 5 |
6 | Partner-Id 6 |
7 | Partner-Id 7 |
8 | Partner-Id 8 |
9 | Partner-Id 9 |
The manufacturer defined default value is 0
(None).
This parameter has the configuration ID config_37_1
and is of type INTEGER
.
Parameter 38: Button 8 Blind Duration
Button 8 Blind Duration
The following option values may be configured -:
Value | Description |
---|---|
3 | Duration 3 Seconds |
30 | Duration 30 Seconds |
60 | Duration 60 Seconds |
90 | Duration 90 Seconds |
120 | Duration 120 Seconds |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_38_1
and is of type INTEGER
.
Parameter 39: Button 8 Output
Button 8 Output
The following option values may be configured -:
Value | Description |
---|---|
0 | No output |
1 | Output number 1 |
2 | Output number 2 |
3 | Output number 3 |
4 | Output number 4 |
5 | Output number 5 |
6 | Output number 6 |
255 | BLANK |
The manufacturer defined default value is 0
(No output).
This parameter has the configuration ID config_39_1
and is of type INTEGER
.
Parameter 40: Button 8 attribute
Button 8 attribute Bit [0] = LED enable
Bit [1] = Sound enable
Bit [2] = Dry contact enable
Bit [3] = Motor enable The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Only Led |
2 | Only Sound |
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_40_1
and is of type INTEGER
.
Parameter 41: Button 9 Type
Button 9 Type 1 = switch on/off
2 = blind up
3 = blind down
4 = switch multiway
5 = blind-up multiway
6 = blind-down multiway The following option values may be configured -:
Value | Description |
---|---|
1 | Switch On/Off |
2 | Blind up |
3 | Blind down |
4 | Switch multiway |
5 | Blind-up multiway |
6 | Blind-down multiway |
The manufacturer defined default value is 1
(Switch On/Off).
This parameter has the configuration ID config_41_1
and is of type INTEGER
.
Parameter 42: Button 9 Partner-Id
Button 9 Partner-Id
- When setting Button (EP) to blind, Partner Id EP also change to blind (opposite direction).
- Blind must contain Partner Id which is different than 0 and it must be unique.
- When setting blind to switch, Partner Id also change to switch The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Partner-Id 1 |
2 | Partner-Id 2 |
3 | Partner-Id 3 |
4 | Partner-Id 4 |
5 | Partner-Id 5 |
6 | Partner-Id 6 |
7 | Partner-Id 7 |
8 | Partner-Id 8 |
9 | Partner-Id 9 |
The manufacturer defined default value is 0
(None).
This parameter has the configuration ID config_42_1
and is of type INTEGER
.
Parameter 43: Button 9 Blind Duration
Button 9 Blind Duration
The following option values may be configured -:
Value | Description |
---|---|
3 | Duration 3 Seconds |
30 | Duration 30 Seconds |
60 | Duration 60 Seconds |
90 | Duration 90 Seconds |
120 | Duration 120 Seconds |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_43_1
and is of type INTEGER
.
Parameter 44: Button 9 Output
Button 9 Output
The following option values may be configured -:
Value | Description |
---|---|
0 | No output |
1 | Output number 1 |
2 | Output number 2 |
3 | Output number 3 |
4 | Output number 4 |
5 | Output number 5 |
6 | Output number 6 |
The manufacturer defined default value is 0
(No output).
This parameter has the configuration ID config_44_1
and is of type INTEGER
.
Parameter 45: Button 9 attributes
Button 9 attributes Bit [0] = LED enable
Bit [1] = Sound enable
Bit [2] = Dry contact enable
Bit [3] = Motor enable The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Only Led |
2 | Only Sound |
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_45_1
and is of type INTEGER
.
Parameter 46: Device Led on intensity
Device Led on intensity
Values in the range 0 to 7 may be set.
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_46_1
and is of type INTEGER
.
Parameter 47: Device Led off intensity
Device Led off intensity
Values in the range 0 to 7 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_47_1
and is of type INTEGER
.
Parameter 48: Device Toggle or Pulse the output
Device Toggle or Pulse the output Device Toggle or Pulse the output:
0 = Toggle
1 = Pulse Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_48_1
and is of type INTEGER
.
Parameter 49: Device Background LEDs Timeout
Device Background LEDs Timeout Device Background LEDs Timeout:
0 = always Off
10 - 40 = Timeout in seconds
255 = always On!!!!!!! Values in the range 0 to 255 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_49_1
and is of type INTEGER
.
Parameter 50: Device touch sensitivity
Device touch sensitivity You can choose value between 0 – 7
0 = most sensitive
7 = least sensitive Values in the range 0 to 7 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_50_1
and is of type INTEGER
.
Parameter 51: Save and Reset
Save and Reset 255 = save and reset The following option values may be configured -:
Value | Description |
---|---|
0 | Do NOT Save and Reset |
255 | Save and Reset |
The manufacturer defined default value is 0
(Do NOT Save and Reset).
This parameter has the configuration ID config_51_1
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The Da Vinci v9 supports 37 association groups.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
Group 2: EP1_SWITCH_BINARY_SET
SWITCH_BINARY_SET
EP1_SWITCH_BINARY_SET
Association group 2 supports 5 nodes.
Group 3: EP1_SWITCH_BINARY_REPORT
SWITCH_BINARY_REPORT
EP1_SWITCH_BINARY_REPORT
Association group 3 supports 5 nodes.
Group 4: EP1_SWITCH_MULTILEVEL_SET
SWITCH_MULTILEVEL_SET
EP1_SWITCH_MULTILEVEL_SET
Association group 4 supports 5 nodes.
Group 5: EP1_SWITCH_MULTILEVEL_REPORT
SWITCH_MULTILEVEL_REPORT
EP1_SWITCH_MULTILEVEL_REPORT
Association group 5 supports 5 nodes.
Group 6: EP2_SWITCH_BINARY_SET
SWITCH_BINARY_SET
Association group 6 supports 5 nodes.
Group 7: EP2_SWITCH_BINARY_REPORT
SWITCH_BINARY_REPORT
Association group 7 supports 5 nodes.
Group 8: EP2_SWITCH_MULTILEVEL_SET
SWITCH_MULTILEVEL_SET
Association group 8 supports 5 nodes.
Group 9: EP2_SWITCH_MULTILEVEL_REPORT
SWITCH_MULTILEVEL_REPORT
Association group 9 supports 5 nodes.
Group 10: EP3_SWITCH_BINARY_SET
SWITCH_BINARY_SET
Association group 10 supports 5 nodes.
Group 11: EP3_SWITCH_BINARY_REPORT
SWITCH_BINARY_REPORT
Association group 11 supports 5 nodes.
Group 12: EP3_SWITCH_MULTILEVEL_SET
SWITCH_MULTILEVEL_SET
Association group 12 supports 5 nodes.
Group 13: EP3_SWITCH_MULTILEVEL_REPORT
SWITCH_MULTILEVEL_REPORT
Association group 13 supports 5 nodes.
Group 14: EP4_SWITCH_BINARY_SET
SWITCH_BINARY_SET
Association group 14 supports 5 nodes.
Group 15: EP4_SWITCH_BINARY_REPORT
SWITCH_BINARY_REPORT
Association group 15 supports 5 nodes.
Group 16: EP4_SWITCH_MULTILEVEL_SET
SWITCH_MULTILEVEL_SET
Association group 16 supports 5 nodes.
Group 17: EP4_SWITCH_MULTILEVEL_REPORT
SWITCH_MULTILEVEL_REPORT
Association group 17 supports 5 nodes.
Group 18: EP5_SWITCH_BINARY_SET
SWITCH_BINARY_SET
Association group 18 supports 5 nodes.
Group 19: EP5_SWITCH_BINARY_REPORT
SWITCH_BINARY_REPORT
Association group 19 supports 5 nodes.
Group 20: EP5_SWITCH_MULTILEVEL_SET
SWITCH_MULTILEVEL_SET
Association group 20 supports 5 nodes.
Group 21: EP5_SWITCH_MULTILEVEL_REPORT
SWITCH_MULTILEVEL_REPORT
Association group 21 supports 5 nodes.
Group 22: EP6_SWITCH_BINARY_SET
SWITCH_BINARY_SET
Association group 22 supports 5 nodes.
Group 23: EP6_SWITCH_BINARY_REPORT
SWITCH_BINARY_REPORT
Association group 23 supports 5 nodes.
Group 24: EP6_SWITCH_MULTILEVEL_SET
SWITCH_MULTILEVEL_SET
Association group 24 supports 5 nodes.
Group 25: EP6_SWITCH_MULTILEVEL_REPORT
SWITCH_MULTILEVEL_REPORT
Association group 25 supports 5 nodes.
Group 26: EP7_ SWITCH_BINARY_SET
SWITCH_BINARY_SET
Association group 26 supports 5 nodes.
Group 27: EP7_SWITCH_BINARY_REPORT
SWITCH_BINARY_REPORT
Association group 27 supports 5 nodes.
Group 28: EP7_ SWITCH_MULTILEVEL_SET
SWITCH_MULTILEVEL_SET
Association group 28 supports 5 nodes.
Group 29: EP7_ SWITCH_MULTILEVEL_REPORT
SWITCH_MULTILEVEL_REPORT
Association group 29 supports 5 nodes.
Group 30: EP8_SWITCH_BINARY_SET
SWITCH_BINARY_SET
Association group 30 supports 5 nodes.
Group 31: EP8_ SWITCH_BINARY_REPORT
SWITCH_BINARY_REPORT
Association group 31 supports 5 nodes.
Group 32: EP8_ SWITCH_MULTILEVEL_SET
SWITCH_MULTILEVEL_SET
Association group 32 supports 5 nodes.
Group 33: EP8_ SWITCH_MULTILEVEL_REPORT
SWITCH_MULTILEVEL_REPORT
Association group 33 supports 5 nodes.
Group 34: EP9_ SWITCH_BINARY_SET
SWITCH_BINARY_SET
Association group 34 supports 5 nodes.
Group 35: EP9_SWITCH_BINARY_REPORT
SWITCH_BINARY_REPORT
Association group 35 supports 5 nodes.
Group 36: EP9_ SWITCH_MULTILEVEL_SET
SWITCH_MULTILEVEL_SET
Association group 36 supports 5 nodes.
Group 37: EP9_ SWITCH_MULTILEVEL_REPORT
SWITCH_MULTILEVEL_REPORT
Association group 37 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 |
Endpoint 1
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
Documentation Links