AZEMT500BB32MA American Standard Z-Wave Programmable Thermostat
This describes the Z-Wave device AZEMT500BB32MA, manufactured by Trane Corporation with the thing type UID of trane_azemt500bb32ma_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The AZEMT500BB32MA supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
T500B Z-Wave Thermostat. The ComfortLink™ control is an innovative product that is compatible with Trane products as well as any other brand of standard central heating and air conditioning systems. It works through the Nexia™ Home Intelligence system
Inclusion Information
Press the MENU button on the thermostat.
Scroll down to Z Wave Install, and press the Select button.
Press the Yes button to enroll the thermostat.
Exclusion Information
Press the MENU button on the thermostat.
Scroll down to Z-Wave Install and press the Select button.
Press the Yes button to exclude the thermostat.
Channels
The following table summarises the channels available for the AZEMT500BB32MA -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Scene Number | scene_number | scene_number | Number | |
Sensor (relative humidity) | sensor_relhumidity | sensor_relhumidity | Humidity | Number |
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
Operating State | thermostat_state | thermostat_state | Temperature | Number |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (cooling) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Thermostat fan mode | thermostat_fanmode | thermostat_fanmode | ||
Thermostat fan state | thermostat_fanstate | thermostat_fanstate | ||
Clock Time Offset | time_offset | time_offset | Time | Number |
Scene Number
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
Sensor (relative humidity)
Indicates the current relative humidity.
The sensor_relhumidity
channel is of type sensor_relhumidity
and supports the Number
item and is in the Humidity
category. This is a read only channel so will only be updated following state changes from the device.
Sensor (temperature)
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Thermostat mode
Sets the thermostat.
The thermostat_mode
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Operating State
Sets the thermostat operating state.
The thermostat_state
channel is of type thermostat_state
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Setpoint (heating)
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Setpoint (cooling)
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Thermostat fan mode
Channel type information on this channel is not found.
Thermostat fan state
Channel type information on this channel is not found.
Clock Time Offset
Provides the current time difference for the devices time.
The time_offset
channel is of type time_offset
and supports the Number
item and is in the Time
category.
Device Configuration
The following table provides a summary of the 1 configuration parameters available in the AZEMT500BB32MA. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
132 | Schedule Mode |
Parameter 132: Schedule Mode
The following option values may be configured -:
Value | Description |
---|---|
0 | Hold |
1 | Schedule |
The manufacturer defined default value is 0
(Hold).
This parameter has the configuration ID config_132_1
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The AZEMT500BB32MA supports 1 association group.
Group 1: Reports
Association group 1 supports 1 node.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V1 | |
COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |