HS-FLS100+ Floodlight Sensor
This describes the Z-Wave device HS-FLS100+, manufactured by HomeSeer Technologies with the thing type UID of homeseer_hsfls100_00_000
.
The device is in the category of Motion Detector, defining Motion sensors/detectors.
The HS-FLS100+ supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
The HS-FLS100+ is a PIR module that’s designed to retrofit onto existing outdoor floodlights. It features a PIR sensor to detect motion through movement of heat sources and a LUX sensor for determining brightness of its surroundings. It is equipped with Z-Wave Plus wireless communication capability that will convert an ordinary motion-activated floodlight into a smart home device.
Conventional Floodlight Mode HS-FLS100+ can be used as a conventional motion-activated floodlight sensor to power floodlights when motion is sensed during dark hours. Controls are provided for manual adjustment of LUX sensitivity and floodlight ON times.
Smart Floodlight Mode When added to a smart home system, HS-FLS100+ will send Z-Wave commands to the smart hub or home controller when motion is sensed and when the LUX level changes. Likewise, the smart hub or home controller can send Z-Wave commands back to the HS-FLS100+ to turn floodlights ON and OFF. This added functionality provides a very high level of flexibility not typically available in conventional motion-activated floodlights.
Smart Sensor Mode HS-FLS100+ can be installed and used simply as an outdoor motion and LUX sensor. Floodlight functionality is not required. This provides some interesting security and smart home possibilities!
Inclusion Information
Press the Link button 3 times within 1.5 seconds to put the unit into inclusion mode.
Exclusion Information
Press the Link button 3 times within 1.5 seconds to put the unit into exclusion mode.
General Usage Information
Channels
The following table summarises the channels available for the HS-FLS100+ -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Binary Sensor | sensor_binary | sensor_binary | Switch | |
Sensor (luminance) | sensor_luminance | sensor_luminance | Number | |
PIR Trigger Off period | config_decimal | config_decimal | Number | |
Lux sensor threshold | config_decimal | config_decimal | Number | |
Auto Report luminance interval | config_decimal | config_decimal | Number | |
Alarm (power) | alarm_power | alarm_power | Energy | Switch |
Motion Alarm | alarm_motion | alarm_motion | Motion | Switch |
Switch
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Binary Sensor
Indicates if a sensor has triggered.
The sensor_binary
channel is of type sensor_binary
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Sensor (luminance)
Indicates the current light reading.
The sensor_luminance
channel is of type sensor_luminance
and supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
PIR Trigger Off period
Range: 8~720 secs
Default: 15
Generic class for configuration parameter.
The config_decimal
channel is of type config_decimal
and supports the Number
item.
Lux sensor threshold
Factory default at 50
Setting = 0: always don’t turn ON light
Setting = 30~200: lighting activation by setting
Setting = 255: turn ON light upon PIR triggered
Generic class for configuration parameter.
The config_decimal
channel is of type config_decimal
and supports the Number
item.
Auto Report luminance interval
Default: 10
Setting: 0~1440 (min.)
Generic class for configuration parameter.
The config_decimal
channel is of type config_decimal
and supports the Number
item.
Alarm (power)
Indicates if a power alarm is triggered.
The alarm_power
channel is of type alarm_power
and supports the Switch
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Motion Alarm
Indicates if a motion alarm is triggered.
The alarm_motion
channel is of type alarm_motion
and supports the Switch
item and is in the Motion
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Device Configuration
The following table provides a summary of the 4 configuration parameters available in the HS-FLS100+. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | PIR Trigger Off Period | Period to send Trigger Off command after PIR is triggered. |
2 | Lux sensor threshold | Lux level to activate the PIR |
3 | Auto Report luminance interval | Sets the interval of periodic lux level report to the controller |
4 | Basic Report |
Parameter 1: PIR Trigger Off Period
Period to send Trigger Off command after PIR is triggered. Period to send Trigger Off command after PIR is triggered. Before this period expires, the PIR will not be able to detect any subsequent motion. Values in the range 8 to 720 may be set.
The manufacturer defined default value is 15
.
This parameter has the configuration ID config_1_2
and is of type INTEGER
.
Parameter 2: Lux sensor threshold
Lux level to activate the PIR When the lux level falls below this threshold and the PIR gets triggered, the unit emits a Basic Set Command (Value=0xFF) and turns on its floodlight. This overwrites the Lux level set by the Lux knob.
Setting = 0: always don’t turn ON light
Setting = 30~200: lighting activation by setting
Setting = 255: turn ON light upon PIR triggered
If the level is set to 0, the unit will not turn on its floodlight. The PIR will still send a notification report to the controller; if the level is set to 255, when motion is sensed, the sensor ignore the ambient brightness but just turn on the light. The following option values may be configured -:
Value | Description |
---|---|
0 | Light is never triggered by PIR |
255 | Light is always triggered by PIR regardless of lux |
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Parameter 3: Auto Report luminance interval
Sets the interval of periodic lux level report to the controller
Values in the range 0 to 1440 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_3_2
and is of type INTEGER
.
Parameter 4: Basic Report
The following option values may be configured, in addition to values in the range 0 to 1 -:
Value | Description |
---|---|
0 | Do not send Basic Report |
1 | Send Basic Report (default) |
The manufacturer defined default value is 1
(Send Basic Report (default)).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The HS-FLS100+ supports 2 association groups.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Device Reset Locally Notification
Notification Report
Binary Report
Sensor Multilevel Report
Basic Report
Association group 1 supports 1 node.
Group 2: PIR Control
Devices in the group are controlled by the PIR sensor Basic Set
Association group 2 supports 4 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V4 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Documentation Links