4.2 KiB
layout | title |
---|---|
documentation | ZW4102 - ZWave |
{% include base.html %}
ZW4102 Energy Monitoring Appliance Module
This describes the Z-Wave device ZW4102, manufactured by Jasco Products with the thing type UID of ge_zw4102_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The ZW4102 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
RF controlled, energy monitoring plug-in relay
Inclusion Information
Tap the button (press and release)
Exclusion Information
Tap the button (press and release)
Channels
The following table summarises the channels available for the ZW4102 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (power factor) | meter_powerfactor | meter_powerfactor | Energy | Number |
Switch
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Electric meter (amps)
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (kWh)
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (watts)
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (volts)
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Electric meter (power factor)
Indicates the instantaneous power factor.
The meter_powerfactor
channel is of type meter_powerfactor
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Device Configuration
The device has no configuration parameters defined.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.